Digitally fabricated weak interfaces to reduce minimum reinforcement in concrete structures

被引:1
|
作者
Bischof, Patrick [1 ]
Mata-Falcon, Jaime [1 ]
Ammann, Rebecca [1 ]
Naesbom, Andreas [1 ]
Kaufmann, Walter [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Civil Environm & Geomat Engn, Inst Struct Engn, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
concrete structures; crack initiators; digital fabrication; material efficiency; minimum reinforcement; weak interfaces; EXTRUSION; SIZE;
D O I
10.1002/suco.202200732
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Crack initiators in reinforced concrete structures can facilitate fulfilling the serviceability requirements. They can be used as a design parameter to diminish the minimum reinforcement for members subject to imposed deformation and exposed to the environment as they reduce the crack spacing and width when arranged close enough. While crack initiators in conventional concrete construction are cumbersome to provide (e.g., by construction joints or taperings), they are inherent to layered extrusion processes with digital fabrication technologies: the tensile strength is typically reduced locally in interfaces between layers. Rather than trying to avoid these weak interfaces, this paper discusses the potential of taking advantage of them to act as crack initiators reducing the minimum reinforcement content. A tension chord-based model is developed to (i) account for the local strength reduction and (ii) predict the effect of weak interfaces on the expected crack spacing and width. As a key finding, the model predicts a reduction of the required minimum reinforcement ratio proportional to the locally decreased concrete tensile strength for a specified maximum crack width requirement under imposed deformations. An experimental campaign on five layered and three reference tension ties confirmed the clearly positive impact of weak interfaces on crack spacings and widths.
引用
收藏
页码:1835 / 1855
页数:21
相关论文
共 50 条
  • [41] Reinforcement and retrofit of concrete structures with aramid fiber
    Sumida, A
    FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, : 273 - 280
  • [42] DETAILING OF REINFORCEMENT IN CONCRETE STRUCTURES - 3.
    Prakash Rao, D.S.
    Indian Concrete Journal, 1985, 59 (03): : 74 - 76
  • [43] Wound FRP Shear Reinforcement for Concrete Structures
    Spadea, Saverio
    Orr, John
    Nanni, Antonio
    Yang, Yuanzhang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (05)
  • [44] Stainless steel reinforcement for durability in concrete structures
    Cochrane, DJ
    NUCLEAR ENERGY-JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1998, 37 (05): : 331 - 336
  • [45] Inspection methods of reinforcement parameters of concrete structures
    Ulybin, A. V.
    MAGAZINE OF CIVIL ENGINEERING, 2012, 27 (01): : 4 - 113
  • [46] Curved non ferrous reinforcement for concrete structures
    Guadagnini, A.
    Imjai, T.
    Pilakoutas, K.
    MEASURING, MONITORING AND MODELING CONCRETE PROPERTIES, 2006, : 719 - +
  • [47] Non-ferrous reinforcement in concrete structures
    Pilakoutas, K
    Achillides, Z
    Waldron, P
    INNOVATION IN COMPOSITE MATERIALS AND STRUCTURES, 1997, : 47 - 56
  • [48] Quality inspection of reinforced concrete Structures and reinforcement
    Bu, Narui
    Cai, Huanqing
    Bai, Runshan
    Li, Zhiqiang
    ADVANCED MECHANICAL DESIGN, PTS 1-3, 2012, 479-481 : 1036 - 1040
  • [49] Reinforcement in tailor-made concrete structures
    Fall, David
    Lundgren, Karin
    Gylltoft, Kent
    NORDIC CONCRETE RESEARCH, 2011, 43 (01): : 175 - 178
  • [50] Advances in Monitoring of Reinforcement Corrosion in Concrete Structures
    Wu, Jin
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 784 - 788