An adaptive targeting algorithm for magnetic resonance-guided high-intensity focused ultrasound controlled hyperthermia

被引:3
|
作者
Wong, Suzanne M. [1 ,2 ]
Luo, Phoebe [1 ]
Keunen, Benjamin [1 ]
Pichardo, Samuel [3 ]
Drake, James M. [1 ,2 ]
Waspe, Adam C. [1 ,4 ]
机构
[1] Hosp Sick Children, Posluns Ctr Image Guided Innovat & Therapeut Inte, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[4] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
controlled hyperthermia; high intensity focused ultrasound; magnetic resonance thermometry; ABLATION; TISSUE;
D O I
10.1002/mp.16414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Mild hyperthermia has been demonstrated to improve the efficacy of chemotherapy, radiation, and immunotherapy in various cancer types. One localized, non-invasive method of administering mild hyperthermia is magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU). However, challenges for ultrasound such as beam deflection, refraction and coupling issues may result in a misalignment of the HIFU focus and the tumor during hyperthermia. Currently, the best option is to stop the treatment, wait for the tissue to cool, and redo the treatment planning before restarting the hyperthermia. This current workflow is both time-consuming and unreliable. Purpose: An adaptive targeting algorithm was developed for MRgHIFU controlled hyperthermia treatments for cancer therapeutics. This algorithm executes in real time while hyperthermia is being administered to ensure that the focus is within our target region. If a mistarget is detected, the HIFU system will electronically steer the focus of the HIFU beam to the correct target. The goal of this study was to quantify the accuracy and precision of the adaptive targeting algorithm's ability to correct a purposely misplanned hyperthermia treatment in real-time using a clinical MRgHIFU system. Methods: A gelatin phantom with acoustic properties matched to the average speed of sound in human tissue was used to test the adaptive targeting algorithm's accuracy and precision. The target was purposely offset 10 mm away from the focus at the origin, in four orthogonal directions, allowing the algorithm to correct for this mistarget. In each direction, 10 data sets were collected for a total sample size of 40. Hyperthermia was administered with a target temperature set at 42 degrees C. The adaptive targeting algorithm was run during the hyperthermia treatment and 20 thermometry images were collected after the beam steering occurred. The location of the focus was quantified by calculating the center of heating on the MR thermometry data. Results: The average calculated trajectory passed to the HIFU system was 9.7 mm +/- 0.4 mm where the target trajectory was 10 mm. The accuracy of the adaptive targeting algorithm after the beam steering correction was 0.9 mm and the precision was 1.6 mm. Conclusion: The adaptive targeting algorithm was implemented successfully and was able to correct the 10 mm mistargets with high accuracy and precision in gelatin phantoms. The results demonstrate the capability to correct the MRgHIFU focus location during controlled hyperthermia.
引用
收藏
页码:3347 / 3358
页数:12
相关论文
共 50 条
  • [31] Transcranial high-intensity Magnetic Resonance-guided focused ultrasound (tcMRgFUS) - safety and impacts on tremor severity and quality of life
    Purrer, Veronika
    Borger, Valeri
    Pohl, Emily
    Upadhyay, Neeraj
    Boecker, Henning
    Schmeel, Carsten
    Pieper, Claus Christian
    Wuellner, Ullrich
    PARKINSONISM & RELATED DISORDERS, 2022, 100 : 6 - 12
  • [32] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Marianne J. Voogt
    Marijn van Stralen
    Marlijne E. Ikink
    Roel Deckers
    Koen L. Vincken
    Lambertus W. Bartels
    Willem P. Th. M. Mali
    Maurice A. A. J. van den Bosch
    CardioVascular and Interventional Radiology, 2012, 35 : 1205 - 1210
  • [33] Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors
    Avedian, Raffi S.
    Gold, Garry
    Ghanouni, Pejman
    Pauly, Kim Butts
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (04): : 303 - 308
  • [34] Acoustic field characterization of a clinical magnetic resonance-guided high-intensity focused ultrasound system inside the magnet bore
    Kothapalli, Satya V. V. N.
    Altman, Michael B.
    Partanen, Ari
    Wan, Leighton
    Gach, H. Michael
    Straube, William
    Hallahan, Dennis E.
    Chen, Hong
    MEDICAL PHYSICS, 2017, 44 (09) : 4890 - 4899
  • [35] Image Segmentation for the Treatment Planning of Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MRgHIFU) Therapy: A Parametric Study
    Vargas-Olivares, Arturo
    Navarro-Hinojosa, Octavio
    Pichardo, Samuel
    Curiel, Laura
    Alencastre-Miranda, Moises
    Enrique Chong-Quero, Jesus
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [36] Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU): Overview of Emerging Applications (Part 2)
    Siedek, Florian
    Yeo, Sin Yuin
    Heijman, Edwin
    Grinstein, Olga
    Bratke, Grischa
    Heneweer, Carola
    Puesken, Michael
    Persigehl, Thorsten
    Maintz, David
    Gruell, Holger
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (06): : 531 - 539
  • [37] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Voogt, Marianne J.
    van Stralen, Marijn
    Ikink, Marlijne E.
    Deckers, Roel
    Vincken, Koen L.
    Bartels, Lambertus W.
    Mali, Willem P. Th M.
    van den Bosch, Maurice A. A. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (05) : 1205 - 1210
  • [38] Prediction of pelvic tumour coverage by magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) from referral imaging
    Lam, Ngo Fung Daniel
    Rivens, Ian
    Giles, Sharon L.
    Harris, Emma
    DeSouza, Nandita M.
    ter Haar, Gail
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 1033 - 1045
  • [39] Magnetic Resonance-Guided Focused Ultrasound Surgery
    Al Hilli, Mariam M.
    Stewart, Elizabeth A.
    SEMINARS IN REPRODUCTIVE MEDICINE, 2010, 28 (03) : 241 - 248
  • [40] Magnetic resonance-guided focused ultrasound surgery
    Hudson, Susan B. A.
    Stewart, Elizabeth A.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01): : 159 - 166