Stability Analysis for DFIG-Based Wind Farm Grid-Connected System Under All Wind Speed Conditions

被引:0
|
作者
Du, Chengmao [1 ]
Du, Xiong [1 ]
Tong, Chenghui [1 ]
Li, Ying [2 ]
Zhou, Peipeng [2 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] China Elect Power Re search Inst, State Key Lab Power Grid Safety & Energy Convers, Beijing 100192, Peoples R China
关键词
Doubly-fed induction generator; two-variable admittance; wake effect; wind farm; wind speed; TURBINE; MODEL; SSR;
D O I
10.1109/TIA.2022.3232468
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The stable operation capability of the doubly-fed induction generation-based wind farm grid-connected system (DFIG-WFGS) is closely related to wind speed, and the windward velocity of wind turbine unit at different locations may be discrepant due to wake effect. However, the existing mathematical models of DFIG is limited to some specific wind speed points, which may not be directly applied to stability analysis in all wind speed operating conditions. The wind speed is used to characterize the steady state operating point in this paper, meanwhile considering the wake effect and single-input and dual-output (SIDO) characteristics, the two-variable admittance models of wind farm based on DFIG are proposed. Further, the improved analysis method based on two-variable open-loop transfer function is proposed to investigate the stable wind speed interval with different series compensation level for a 50MW DFIG-WFGS in Qinghai, China. In addition, a design guideline of wind farm for oscillation suppression is studied to enhance the performance of DFIG-WFGS and avoid unstable operations. Theoretical analysis and simulation results show that the wake effect may discontinuous the stable wind speed interval, and the damping variation is not positively correlated with the wind speed, which provides basis for accurate analysis and effective improvement of the stability for wind power generation system.
引用
收藏
页码:2430 / 2445
页数:16
相关论文
共 50 条
  • [31] Multiple machine representation of DFIG-based grid-connected wind farms for SSR studies.
    Atayde, S.
    Chandra, A.
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 1468 - 1473
  • [32] Resonance Analysis of DFIG-Based Offshore Wind Farm
    Zhao, Weiguo
    Xie, Caike
    Liu, Yutian
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [33] Coupling DFIG-Based Wind Turbines with the Grid under Voltage Imbalance Conditions
    Sobhy, Ahmed
    Abo-Khalil, Ahmed G.
    Lei, Dong
    Salameh, Tareq
    Merabet, Adel
    Alkasrawi, Malek
    SUSTAINABILITY, 2022, 14 (09)
  • [34] Transient Stability Analysis of DFIG-based Wind Farm Integrated Power System With Distributed Loads
    Wankhede, Sumeet K.
    Mitra, Arghya
    2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, : 182 - 187
  • [35] DFIG with Grid-Connected Rotor for Wind Energy Conversion System
    David, Nicholas
    Aliprantis, Dionysios C.
    2013 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2013, : 125 - 130
  • [36] Application of SFCL to Improve the Transient Voltage Stability of Grid-Connected Wind Farm with DFIG during Grid Faults
    Ou, Ran
    Xiao, Xian Yong
    Zou, Zhi Ce
    Li, Chang Song
    Wu, Dan Yue
    2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 240 - 241
  • [37] Cooperative Rotor-Side SMES and Transient Control for Improving the LVRT Capability of Grid-Connected DFIG-Based Wind Farm
    Xiao, Xian-Yong
    Yang, Ruo-Huan
    Zheng, Zi-Xuan
    Wang, Ying
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [38] Analysis of influencing factors of subsynchronous oscillation caused by a DFIG-based wind farm via the VSC-HVDC grid-connected system based on a data driven method
    Xu X.
    Bian X.
    Zhang Q.
    Chang X.
    Huang R.
    Sun K.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (21): : 80 - 87
  • [39] Stability Assessment of DFIG-Based Wind Turbines Equipped with Modified Virtual Inertial Controller under Variable Wind Speed Conditions
    Ravanji, Mohammad Hasan
    Parniani, Mostafa
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 2695 - 2700
  • [40] Contribution of DFIG-Based Wind Farm to System Frequency Control
    Aktarujjaman, M.
    Haque, M. E.
    Negnevitsky, M.
    2012 7TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2012,