Experimental investigation on the seismic performance of prefabricated fiber-reinforced concrete beam-column joints using grouted sleeve connections

被引:5
|
作者
Sun, Chuanzhi [1 ]
Zhuang, Mei-Ling [2 ,6 ]
Wang, Zhenbo [3 ]
Chen, Baodong [3 ]
Gao, Li [1 ]
Qiao, Yan [1 ]
Zhu, Hanbo [1 ]
Zhang, Weihua [4 ]
Yang, Jun [5 ]
Yu, Changrong [2 ]
机构
[1] Suqian Coll, Sch Civil Engn & Architecture, Suqian, Peoples R China
[2] Nantong Univ, Sch Transportat & Civil Engn, Nantong, Peoples R China
[3] Nanjing Tech Univ, Coll Civil Engn, Nanjing, Peoples R China
[4] Yigongju Bridge & Tunnel Engn Co Ltd, Changsha, Peoples R China
[5] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou, Peoples R China
[6] Nantong Univ, Sch Transportat & Civil Engn, Nantong 226019, Peoples R China
关键词
beam-column joint; fiber-reinforced concrete; prefabricated reinforced concrete structure; seismic performance; sleeve connection; wet joint; FLEXURAL MEMBERS; BEHAVIOR; ECC; DUCTILITY; FRAMES;
D O I
10.1002/suco.202200823
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve the seismic performance of prefabricated reinforced conventional concrete (PRC) beam-column joints, fiber-reinforced concrete (FRC) was used instead of concrete in the core zone of the joint in this article. The optimum volume contents of polyvinyl alcohol (PVA) fibers and steel fibers were first determined to be 0.3% and 1%, respectively, through the material properties tests. Then, four PRC beam-column joint specimens using grouted sleeve connections and one cast-in-place reinforced concrete beam-column joint specimen were designed considering the factors of PVA fibers, steel fibers, with or without stirrups. The test phenomena and failure mode of the five specimens under low-cycle cyclic loads were obtained. Finally, the effects of PVA fibers, steel fibers, with or without stirrups on the seismic performance of specimens were analyzed and discussed. The test phenomena indicated that the failure mode of specimens was anchorage damage of steel bars. The prefabricated FRC specimens showed relatively little damage in the core zone of the joint. FRC had a significant improvement on the seismic performance of prefabricated beam-column joints. The use of FRC in the core zone of the joint can reduce or even eliminate the use of stirrups.
引用
收藏
页码:4702 / 4718
页数:17
相关论文
共 50 条
  • [41] Seismic Behavior and Shear Bearing Capacity of Ultra-High Performance Fiber-Reinforced Concrete (UHPFRC) Beam-Column Joints
    Wang, Dehong
    Ju, Yanzhong
    Zheng, Wenzhong
    Shen, Hao
    APPLIED SCIENCES-BASEL, 2018, 8 (05):
  • [42] Experimental study on seismic behaviour of precast recycled fine aggregate concrete beam-column joints with pressed sleeve connections
    Yuan, Chang-Min
    Cai, Jian
    Chen, Qing-Jun
    Liu, Xinpei
    Huang, Houjun
    Zuo, Zhiliang
    He, An
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [43] The seismic design and performance of reinforced concrete beam-column knee joints in buildings
    Megget, LM
    EARTHQUAKE SPECTRA, 2003, 19 (04) : 863 - 895
  • [44] Experimental investigation and database construction of seismic performance of beam-column connections
    Lee, Hung-Jen
    Chang, You-Ren
    Hwang, Shyh-Jiann
    Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2014, 26 (03): : 257 - 263
  • [45] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M. J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI JOURNAL, 2015, : 80 - 103
  • [46] Seismic resistant design methods for steel fiber reinforced concrete beam-column connections
    Ji, Tao
    Zheng, Jian-Lan
    Lin, Xu-Jian
    Gongcheng Lixue/Engineering Mechanics, 2006, 23 (05): : 94 - 98
  • [47] Seismic behavior of beam-column joints strengthened with ultra-high performance fiber reinforced concrete
    Khan, Muhammad Irfan
    Al-Osta, Mohammed Ali
    Ahmad, Shamsad
    Rahman, Muhammad Kalimur
    COMPOSITE STRUCTURES, 2018, 200 : 103 - 119
  • [48] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Gamble, Bill
    PCI JOURNAL, 2015, : 97 - 98
  • [49] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M.J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI Journal, 2015, 60 (02): : 80 - 103
  • [50] REINFORCED CONCRETE BEAM-COLUMN JOINTS FOR SEISMIC LOADING.
    Fenwick, R.C.
    Irvine, H.M.
    Bulletin of the New Zealand Society for Earthquake Engineering, 1977, 10 (04): : 174 - 185