Power consumption of model houses with and without PCM plaster lining using different heating methods

被引:5
|
作者
Nemeth, Bence [1 ]
Ujhidy, Aurel [1 ]
Toth, Judit [1 ]
Ferencz, Monika [1 ,2 ]
Kurdi, Robert [2 ]
Gyenis, Janos [1 ]
Feczko, Tivadar [1 ,2 ]
机构
[1] Res Ctr Nat Sci, Inst Mat & Environm Chem, Magyar tudosok korutja 2, H-1117 Budapest, Hungary
[2] Univ Pannonia, Fac Engn, Egyet u 10, H-8200 Veszprem, Hungary
关键词
Thermal energy storage; Phase change material; Microencapsulation; Building envelope; Heating efficiency; PHASE-CHANGE MATERIALS; THERMAL PERFORMANCE; STORAGE TANK; PUMP SYSTEM; ENERGY; PARAMETERS; REDUCTION; DEMAND; DESIGN; GYPSUM;
D O I
10.1016/j.enbuild.2023.112845
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal behaviour and power demand of two container model houses were studied. One of them was equipped with plaster lining with incorporated PCM microcapsules, and the second one served as refer-ence during two successive winter periods. In the first winter period of 2019/20, an electric radiator was applied for heating the houses during the daytime, and then they were let cool down from evening to the next morning. The dynamic thermal behaviour and power demand of the model houses were investi-gated during the heating up periods, then in a quasi-thermal equilibrium, as well as along their sponta-neous cooling down process at changing environmental temperatures. The indoor and environmental air temperatures, internal and external wall surface temperatures were collected by data logger during the whole winter periods for both model houses. Through the second winter period of 2020/21 the same methodology was used; nevertheless, the model houses were heated by air-air heat pumps. The perfor-mance coefficient (COP) of heat pumps was compared to the electric radiators. The estimated COP showed significant correlation with the temperature differences between the outdoor and indoor air tem-peratures, considerable worsening from COP = 3.1-3.4 to COP = 2.0-2.1 with increasing temperature drop to be overcome by the applied air-air heat pumps. However, there was no considerable dependence observed between the reference and PCM plaster lined houses. Equations were suggested to estimate the power demand in quasi-thermal equilibrium for both model houses and both heating methods as a function of the temperature differences between indoor and outdoor air. The power demand of PCM plaster lined model house compared to the reference house was lower by 10.3 % and 7.0 % using electric radiators or heat pumps, respectively, throughout the whole winter period, considering a medium tem-perature drop of 20 degrees C through the walls.(c) 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Thermal effects of a novel phase change material (PCM) plaster under different insulation and heating scenarios
    Kusama, Yuka
    Ishidoya, Yuji
    ENERGY AND BUILDINGS, 2017, 141 : 226 - 237
  • [2] Indoor Air Quality Evaluation in Rural Houses Using Different Heating Methods in Northern Shanxi, China
    Zhang, Mengying
    Dong, Xujuan
    Feng, Jing
    SUSTAINABILITY, 2024, 16 (14)
  • [3] Thermal management of using crystallization-controllable supercooled PCM in space heating applications for different heating profiles in the UK
    Kutlu, Cagri
    Su, Yuehong
    Lyu, Qinghua
    Riffat, Saffa
    RENEWABLE ENERGY, 2023, 206 : 848 - 857
  • [4] Wear of truck brake lining materials using three different test methods
    Blau, PJ
    Jolly, BC
    WEAR, 2005, 259 : 1022 - 1030
  • [5] Black-Box Model for Predicting HVAC Energy Consumption and PCM State with Different Melting Temperatures of PCM for Small Office Buildings
    Al Jebaei, Hussein
    Aryal, Ashrant
    CONSTRUCTION RESEARCH CONGRESS 2024: ADVANCED TECHNOLOGIES, AUTOMATION, AND COMPUTER APPLICATIONS IN CONSTRUCTION, 2024, : 1327 - 1336
  • [6] Power System Consumption Model using SPICE
    Sanchis-Kilders, E.
    Ferreres, A.
    Gasent-Blesa, J. L.
    Osorno, D.
    Gilabert, D.
    Maset, E.
    Ejea, J. B.
    Esteve, V.
    Jordan, J.
    2014 IEEE 15TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2014,
  • [7] Solubilization of bovine gelatin using power ultrasound: gelation without heating
    Farahnaky, Asgar
    Zendeboodi, Fatemeh
    Azizi, Rezvan
    Mesbahi, Gholamreza
    Majzoobi, Mahsa
    JOURNAL OF TEXTURE STUDIES, 2017, 48 (02) : 87 - 94
  • [8] Experimental investigation on power consumption of an industrial fan with different flow control methods
    Jena, Madhab C.
    Mishra, Sarat K.
    Moharana, Himanshu S.
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2020, 39 (01)
  • [9] Applying Classification Methods to Model Standby Power Consumption in the Internet of Things
    Andrade, Leandro
    Rios, Ricardo
    Nogueira, Tatiane
    Prazeres, Cassio
    PROCEEDINGS OF THE 2017 IEEE 14TH INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL (ICNSC 2017), 2017, : 537 - 542
  • [10] Comparing the energy performance of Australian houses using NatHERS modelling against measured household energy consumption for heating and cooling
    O'Leary, Timothy
    Belusko, M.
    Whaley, D.
    Bruno, F.
    ENERGY AND BUILDINGS, 2016, 119 : 173 - 182