The performance of 68Ga-FAPI-04 PET/CT in head and neck squamous cell carcinoma: a prospective comparison with 18F-FDG PET/CT

被引:13
|
作者
Jiang, Yaqun [1 ]
Wen, Bing [1 ]
Li, Chongjiao [1 ]
Tian, Yueli [1 ]
Xiao, Zhiwei [1 ]
Xu, Kui [1 ]
Xing, Diankui [1 ]
Yu, Zili [2 ]
Huang, Jing [3 ]
Jia, Jun [2 ]
He, Yong [1 ]
机构
[1] Wuhan Univ, Zhongnan Hosp, Dept Nucl Med, Wuhan 430071, Peoples R China
[2] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Surg, Wuhan 430079, Peoples R China
[3] Wuhan Univ, Zhongnan Hosp, Dept Otorhinolaryngol Head & Neck Surg, Wuhan 430071, Peoples R China
基金
中国国家自然科学基金;
关键词
HNSCC; Ga-68-FAPI-04; PET/CT; F-18-FDG; Staging; LYMPH-NODE METASTASES; FDG-PET/CT; CANCER; CT; ACCURACY; RECIST; TUMORS;
D O I
10.1007/s00259-023-06138-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study was designed to compare the performance of Ga-68-FAPI-04 and F-18-FDG PET/CT for initial staging and recurrence detection of head and neck squamous cell carcinoma (HNSCC). Methods Prospectively, 77 patients with histologically proven or highly suspected HNSCC underwent paired F-18-FDG and Ga-68-FAPI-04 PET/CT in a week for either initial staging (n = 67) or restaging (n = 10). The diagnostic performance was compared for the two imaging approaches, especially for N staging. SUVmax, SUVmean, and target-to-background ratio (TBR) were assessed for paired positive lesions. Furthermore, change in management by Ga-68-FAPI-04 PET/CT and histopathologic FAP expression of some lesions were explored. Results F-18-FDG and Ga-68-FAPI-04 PET/CT exhibited a comparable detection efficiency for primary tumor (100%) and recurrence (62.5%). In the twenty-nine patients receiving neck dissection, Ga-68-FAPI-04 PET/CT showed greater specificity and accuracy in evaluating preoperative N staging than F-18-FDG based on patient (p = 0.031 and p = 0.070), neck side (p = 0.002 and p = 0.006), and neck level (p < 0.001 and p < 0.001). As for distant metastasis, Ga-68-FAPI-04 PET/CT detected more positive lesions than F-18-FDG (25 vs 23) and with higher SUVmax (7.99 +/- 9.04 vs 3.62 +/- 2.68, p = 0.002) by lesion-based analysis. The type of neck dissection in 9 cases (9/33) was altered by Ga-68-FAPI-04. Overall, clinical management was significantly changed in 10 patients (10/61). Three patients had a follow-up Ga-68-FAPI-04 PET/CT post neoadjuvant therapy: One showed complete remission, and the others showed progression. The Ga-68-FAPI-04 uptake intensity was confirmed to be consistent with FAP expression. Conclusion Ga-68-FAPI-04 outperforms F-18-FDG PET/CT in evaluating preoperative N staging in patients with HNSCC. Furthermore, Ga-68-FAPI-04 PET/CT also shows the potential in clinical management and monitoring response to treatment.
引用
收藏
页码:2114 / 2126
页数:13
相关论文
共 50 条
  • [41] Head-to-head comparison of 68Ga-FAPI-04 PET/CT and 18F-FDG PET/CT in the evaluation of primary digestive system cancer: a systematic review and meta-analysis
    Ouyang, Jiqi
    Ding, Peiwen
    Zhang, Runshun
    Lu, Yuexia
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [42] 68Ga-DOTA-FAPI-04 PET/CT in Neuroendocrine Carcinoma of the Liver With Elevated AFP Level Comparison With 18F-FDG PET/CT
    Ergul, Nurhan
    Yilmaz, Burcak
    Cin, Merve
    Cermik, Tevfik Fikret
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (01) : E29 - E31
  • [43] Head-to-head Comparison of 68Ga-FAPI PET/CT and 18F-FDG PET/CT in Fumarate Hydratase-Deficient Renal Cell Carcinoma
    Huang, Shuhui
    Huang, Rui
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [44] 68Ga-FAPI-04 PET/CT in Renal Cell Carcinoma: A Preliminary Study
    Civan, C.
    Kuyumcu, S.
    Simsek, D. Has
    Sanli, O.
    Ozkan, Z.
    Hurdogan, O.
    Sanli, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S581 - S581
  • [45] Head-to-head comparison of the detection performance and tumor uptake of 68Ga-FAPI-04 and 18F-FDG PET/CT in liver metastases from cancers of different type
    Ma, G.
    Song, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S340 - S340
  • [46] Comparison of 18F-FDG PET/CT and 68Ga-FAPI in Spindle Cell Rhabdomyosarcoma
    Shen, Zhihui
    Wang, Ruimin
    DIAGNOSTICS, 2023, 13 (18)
  • [47] 68Ga-DOTA-FAPI-04 PET/MR in the Evaluation of Gastric Carcinomas: Comparison with 18F-FDG PET/CT
    Qin, Chunxia
    Shao, Fuqiang
    Gai, Yongkang
    Liu, Qingyao
    Ruan, Weiwei
    Liu, Fang
    Hu, Fan
    Lan, Xiaoli
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (01) : 81 - 88
  • [48] Comparison of [68 Ga]Ga-DOTA-FAPI-04 PET/CT and [18F]FDG PET/CT in colorectal cancer
    Komek, Halil
    Can, Canan
    Kaplan, Ihsan
    Gundogan, Cihan
    Kepenek, Ferat
    Karaoglan, Huseyin
    Demirkiran, Aykut
    Ebinc, Senar
    Guzel, Yunus
    Gundes, Ebubekir
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (11) : 3898 - 3909
  • [49] Comparison of [68 Ga]Ga-DOTA-FAPI-04 PET/CT and [18F]FDG PET/CT in colorectal cancer
    Halil Kömek
    Canan Can
    İhsan Kaplan
    Cihan Gündoğan
    Ferat Kepenek
    Hüseyin Karaoglan
    Aykut Demirkıran
    Senar Ebinç
    Yunus Güzel
    Ebubekir Gündeş
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3898 - 3909
  • [50] Comparison of 68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT in Patients With SAPHO Syndrome
    Wang, Peipei
    Li, Chen
    Hou, Guozhu
    Li, Zhaohui
    Jing, Hongli
    Zhang, Wen
    Li, Fang
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (09) : 781 - 784