Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study

被引:2
|
作者
Deffet, Sylvain [1 ,5 ]
Hamaide, Valentin [2 ]
Sterpin, Edmond [1 ,3 ,4 ]
机构
[1] Catholic Univ Louvain, Inst Rech Expt & Clin IREC, Ctr Mol Imaging Radiotherapy & Oncol MIRO, Louvain La Neuve, Belgium
[2] Ion Beam Applicat SA, Louvain La Neuve, Belgium
[3] Katholieke Univ Leuven, Dept Oncol, Lab Expt Radiotherapy, Leuven, Belgium
[4] Particle Therapy Interuniv Ctr Leuven PARTICLE, Leuven, Belgium
[5] Catholic Univ Louvain, Ctr Mol Imaging Radiotherapy & Oncol MIRO, Inst Rech Expt & Clin IREC, B-1348 Louvain La Neuve, Belgium
关键词
dose rate; FLASH; flash proton therapy;
D O I
10.1002/mp.16607
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundFLASH proton therapy has the potential to reduce side effects of conventional proton therapy by delivering a high dose of radiation in a very short period of time. However, significant progress is needed in the development of FLASH proton therapy. Increasing the dose rate while maintaining dose conformality may involve the use of advanced beam-shaping technologies and specialized equipment such as 3D patient-specific range modulators, to take advantage of the higher transmission efficiency at the highest energy available. The dose rate is an important factor in FLASH proton therapy, but its definition can vary because of the uneven distribution of the dose over time in pencil-beam scanning (PBS). PurposeHighlight the distinctions, both in terms of concept and numerical values, of the various definitions that can be established for the dose rate in PBS proton therapy. MethodsIn an in silico study, five definitions of the dose rate, namely the PBS dose rate, the percentile dose rate, the maximum percentile dose rate, the average dose rate, and the dose averaged dose rate (DADR) were analyzed first through theoretical comparison, and then applied to a head and neck case. To carry out this study, a treatment plan utilizing a single energy level and requiring the use of a patient-specific range modulator was employed. The dose rate values were compared both locally and by means of dose rate volume histograms (DRVHs). ResultsThe PBS dose rate, the percentile dose rate, and the maximum percentile dose are definitions that are specifically designed to take into account the time structure of the delivery of a PBS treatment plan. Although they may appear similar, our study shows that they can vary locally by up to 10%. On the other hand, the DADR values were approximately twice as high as those of the PBS, percentile, and maximum percentile dose rates, since the DADR disregards the periods when a voxel does not receive any dose. Finally, the average dose rate can be defined in various ways, as discussed in this paper. The average dose rate is found to be lower by a factor of approximately 1/2 than the PBS, percentile, and maximum percentile dose rates. ConclusionsWe have shown that using different definitions for the dose rate in FLASH proton therapy can lead to variations in calculated values ranging from a few percent to a factor of two. Since the dose rate is a critical parameter in FLASH radiation therapy, it is essential to carefully consider the choice of definition. However, to make an informed decision, additional biological data and models are needed.
引用
收藏
页码:5784 / 5792
页数:9
相关论文
共 50 条
  • [21] REDUCING DOSE TO DENTOFACIAL STRUCTURES: A PENCIL-BEAM SCANNING PROTON THERAPY AND VOLUMETRIC-ARC THERAPY PHOTON TREATMENT PLANNING COMPARISON STUDY
    Davies, Lucy Siew Chen
    Charlwood, Frances
    Hol, Marinka
    Aznar, Marianne C.
    Davey, Angela
    Eccles, Cynthia
    Foster-Thomas, Emma
    Gaito, Simona
    Gaze, Mark
    Indelicato, Danny
    Mandeville, Henry
    Slater, Olga
    Sitch, Peter
    Tang, Vivian
    Whitfield, Gillian
    Pan, Shermaine
    [J]. PEDIATRIC BLOOD & CANCER, 2023, 70 : S68 - S69
  • [22] Successful Implementation of Image-Guided Pencil-Beam Scanning Proton Therapy in Medulloblastomas
    Das, Anindita
    Gaikwad, Utpal
    Krishnan, Ganapathy
    Rajendran, Adhithyan
    Patil, Sushama
    Subramaniam, Preethi
    Krishna, Uday
    Wakde, Manoj
    Chilukuri, Srinivas
    Jalali, Rakesh
    [J]. DIAGNOSTICS, 2023, 13 (21)
  • [23] Interplay Effect of Target Motion and Pencil-Beam Scanning in Proton Therapy for Pediatric Patients
    Boria, Andrew J.
    Uh, Jinsoo
    Pirlepesov, Fakhriddin
    Stuckey, James C.
    Axente, Marian
    Gargone, Melissa A.
    Hua, Chia-ho
    [J]. INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2018, 5 (02) : 1 - 10
  • [24] Increased Efficiency of Range Verification in Routine QA for Pencil-Beam Scanning Proton Therapy
    Jeong, Seonghoon
    Yoon, Myonggeun
    Son, Jaeman
    Chung, Kwangzoo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (07) : 983 - 989
  • [25] Increased Efficiency of Range Verification in Routine QA for Pencil-Beam Scanning Proton Therapy
    Seonghoon Jeong
    Myonggeun Yoon
    Jaeman Son
    Kwangzoo Chung
    [J]. Journal of the Korean Physical Society, 2018, 73 : 983 - 989
  • [26] Towards FLASH proton therapy: achievable dose rates in geometrical and clinical fields for pencil beam scanning
    Safai, Sairos
    Safai, Sairos
    van de Water, Steven
    Weber, Damien C.
    Lomax, Antony J.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1135 - 1135
  • [27] Optimal minimum MU for intensity-modulated proton therapy with pencil-beam scanning proton beams
    Yi, Byongyong
    Mossahebi, Sina
    Jatczak, Jenna
    Mundis, Michelle
    Houser, Thomas
    Alicia, David
    Han, Dong
    Gonzalez, Rosette
    Olis, Stephen
    Zakhary, Mark
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [28] SDDRO-PBS: Simultaneous Dose and Dose Rate Optimization for FLASH Proton SBRT Based on Pencil Beam Scanning Dose Rate Modeling
    Gao, H.
    Folkerts, M. M.
    Lin, Y.
    Abel, E.
    Bradley, J. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E553 - E553
  • [29] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [30] Incorporation of the aperture thickness in proton pencil-beam dose calculations
    Slopsema, Roelf L.
    Kooy, Hanne M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5441 - 5453