Impact of intra- and extramedullary alignment on blood loss in total knee arthroplasty: a retrospective study

被引:0
|
作者
Meissner, Nils [1 ]
Frenzel, Alexander [2 ]
Halder, Andreas M. [1 ]
Preis, Alexander [1 ]
Sina, Jonas P. [1 ]
Schrednitzki, Daniel [1 ]
机构
[1] Sana Kliniken Sommerfeld, Dept Orthopaed Surg, Waldhausstr 44, D-16766 Kremmen, Germany
[2] Carl Thiem Klinikum Cottbus, Dept Orthopaed, Thiemstr 111, D-03046 Cottbus, Germany
关键词
Total knee arthroplasty; Extramedullary tibial alignment; Intramedullary tibial alignment; Blood loss; Patient blood management; TOTAL HIP-ARTHROPLASTY; MANAGEMENT STRATEGIES; TRANSFUSION RATE; OUTCOMES; SURGERY; ANEMIA;
D O I
10.1007/s00402-024-05232-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background There is a scarcity of scientific data regarding the correlation between alignment techniques during total knee arthroplasty (TKA) and blood loss as well as transfusion rates. This study's hypothesis posited that intramedullary-aligned (IM) TKA exhibits higher blood loss and transfusion rates when contrasted with extramedullary-aligned (EM) TKA. Methods We conducted a retrospective examination of 883 patients who underwent total knee arthroplasty (TKA) in 2021 at a solitary orthopedic center in Germany. These patients were divided into two groups based on their tibial alignment technique: extramedullary alignment and intramedullary tibial alignment. Results In the intramedullary tibial alignment (IM) group, we observed a blood loss of 0.91 L, while in the extramedullary tibial alignment (EM) group, the blood loss was 0.89 L. These values did not demonstrate a significant difference (p = 0.69). Transfusion rates were 0.99% in the IM group and 0.21% in the EM group, and there was no significant distinction between them (Chi-squared test: p > 0.05). Conclusion We observed no statistically significant variance in blood loss between the IM and EM groups. Likewise, there was no substantial disparity in transfusion rates between these groups. It can be concluded that the selection of a knee arthroplasty system incorporating either intramedullary tibial alignment or extramedullary alignment does not significantly impact blood loss.
引用
收藏
页码:1901 / 1905
页数:5
相关论文
共 50 条
  • [21] Alignment in total knee arthroplasty
    Becker, Roland
    Tandogan, Reha
    Violante, Bruno
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2393 - 2394
  • [22] Alignment in total knee arthroplasty
    Roland Becker
    Reha Tandogan
    Bruno Violante
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2393 - 2394
  • [23] A COMPARISON OF INTRAMEDULLARY AND EXTRAMEDULLARY ALIGNMENT SYSTEMS FOR TIBIAL COMPONENT PLACEMENT IN TOTAL KNEE ARTHROPLASTY
    BRYS, DA
    LOMBARDI, AV
    MALLORY, TH
    VAUGHN, BK
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (263) : 175 - 179
  • [24] Intramedullary versus extramedullary alignment guides on total knee arthroplasty: a meta-analysis
    Qin, Ya-fei
    Li, Na
    Shi, Yong-xin
    Sun, Kai
    Li, Zhi-jun
    Li, Hui
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2018, 7 (12) : 1181 - 1193
  • [25] Accuracy of a novel extramedullary femoral alignment guide system in primary total knee arthroplasty
    Matsumoto, Kazu
    Mori, Nobuyuki
    Ogawa, Hiroyasu
    Akiyama, Haruhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (12) : 1743 - 1748
  • [26] ACCURACY OF INTRAMEDULLARY VERSUS EXTRAMEDULLARY TIBIAL ALIGNMENT CUTTING SYSTEMS IN TOTAL KNEE ARTHROPLASTY
    TETER, KE
    BREGMAN, D
    COLWELL, CW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (321) : 106 - 110
  • [27] Accuracy of a novel extramedullary femoral alignment guide system in primary total knee arthroplasty
    Kazu Matsumoto
    Nobuyuki Mori
    Hiroyasu Ogawa
    Haruhiko Akiyama
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1743 - 1748
  • [28] Intra- and inter-operator reliability assessment of a novel extramedullary accelerometer-based smart cutting guide for total knee arthroplasty: an in vivo study
    Giulio Maria Marcheggiani Muccioli
    Domenico Alesi
    Arcangelo Russo
    Mirco Lo Presti
    Iacopo Sassoli
    Matteo La Verde
    Stefano Zaffagnini
    International Orthopaedics, 2023, 47 : 83 - 87
  • [29] Intra- and inter-operator reliability assessment of a novel extramedullary accelerometer-based smart cutting guide for total knee arthroplasty: an in vivo study
    Muccioli, Giulio Maria Marcheggiani
    Alesi, Domenico
    Russo, Arcangelo
    Lo Presti, Mirco
    Sassoli, Iacopo
    La Verde, Matteo
    Zaffagnini, Stefano
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (01) : 83 - 87
  • [30] The Effect of Intra-articular Epinephrine Lavage on Blood Loss Following Total Knee Arthroplasty
    Malone, Kevin J.
    Matuszak, Sean
    Mayo, David
    Greene, Perry
    ORTHOPEDICS, 2009, 32 (02) : 100 - 103