Dual-interrogation method for suppressing light shift in Rb 778 nm two-photon transition optical frequency standard

被引:3
|
作者
Li, Dou [1 ]
Liu, Kangqi [1 ,2 ]
Wang, Pengfei [1 ]
Kang, Songbai [1 ]
机构
[1] Chinese Acad Sci, Innovat Acad Precis Measurement Sci & Technol, Key Lab Atom Frequency Stand, Wuhan 430071, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
CLOCKS; LASER;
D O I
10.1364/OE.512205
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, a dual -interrogation (DI) method was used to suppress the light shift in the Rb 778 nm 5S1/2 -*5D5/2 two -photon transition optical frequency standard (2hv-OFS). The approach used an auxiliary system to calibrate the light shift of the primary system in real time to mitigate the absolute light shift and suppress the sensitivity of the system to the light power. Results show that after using the DI method, the absolute light shift and light -power sensitivity of the system were reduced by a factor of 10. The proposed method will improve the accuracy of the Rb 778 nm 2hv-OFS and increase the mid- and long-term stability. The method can also be applied to other vapor -cell atomic frequency standards that experience light shifts. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:2766 / 2773
页数:8
相关论文
共 50 条
  • [21] An absolute frequency reference at 192.6 THz (1556 nm) based on a two-photon absorption line of rubidium at 778 nm for WDM communication systems
    Poulin, M
    Latrasse, C
    Cyr, N
    Tetu, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1997, 9 (12) : 1631 - 1633
  • [22] Progress in the development of an optical frequency standard at 192.6 THz based on a two-photon transition of rubidium atoms at Laval University
    Universite Laval, Ste-Foy, Canada
    Proc Annu IEEE Int Freq Control Symp, (726-729):
  • [23] Light shift compensation in a Rb gas cell frequency standard with two-laser pumping
    Deng, JQ
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (06) : 1657 - 1661
  • [24] Light shift compensation in a Rb gas cell frequency standard with two-laser-pumping
    Deng, JQ
    PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, : 659 - 663
  • [25] Light shift mitigation for the 5S-5D two-photon transition in rubidium
    Blum, Roman
    Kundermann, Stefan
    Ruelle, Thibaud
    Lecomte, Steve
    Karlen, Sylvain
    QUANTUM TECHNOLOGIES 2024, 2024, 12993
  • [26] ATOMIC TRANSITION FREQUENCY-SHIFT IN RB87 DUE TO OPTICAL-PUMPING IN A PASSIVE FREQUENCY STANDARD
    BESPALOVA, MP
    MISHAKOV, GA
    PIKHTELE.AI
    RADIOTEKHNIKA I ELEKTRONIKA, 1973, 18 (11): : 2356 - 2363
  • [27] A stable frequency standard based on the one-color two-photon 5S-7S transition of rubidium at 760 nm
    Wang, Sandan
    Yuan, Jinpeng
    Wang, Lirong
    Xiao, Liantuan
    Jia, Suotang
    LASER PHYSICS LETTERS, 2019, 16 (12)
  • [28] Absolute hyperfine energy levels and isotope shift of Rb 5S-6S two-photon transition
    Orson, S. T.
    McLaughlin, C. D.
    Lindsay, M. D.
    Knize, R. J.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2021, 54 (17)
  • [29] Impact of the frequency error of direct digital synthesizers on the evaluation of two-photon light shift in atom gravimeters
    Zhu, Dong
    Liu, Naike
    Cheng, Bing
    Cao, Pengfei
    Wu, Bin
    Wang, Kainan
    Wu, Liming
    Weng, Kanxing
    Zhou, Yin
    Bian, Jinglong
    Wang, Xiaolong
    Lin, Qiang
    OPTICS EXPRESS, 2024, 32 (23): : 40554 - 40566
  • [30] High-Resolution Rb Two-Photon Transition Spectroscopy by a Femtosecond Frequency Comb via Pulses Control
    张一驰
    范鹏瑞
    元晋鹏
    汪丽蓉
    肖连团
    贾锁堂
    Chinese Physics Letters, 2016, (11) : 40 - 42