Correction of axial length measurement error by IOLMaster 700 could improve refractive prediction accuracy in silicone oil-filled eyes

被引:0
|
作者
Zhang, Jiaqing [1 ,2 ]
Han, Xiaotong [1 ,2 ]
Jin, Aixia [1 ,2 ]
Zhang, Yifan [1 ,2 ]
Chen, Xiaoyun [1 ,2 ]
Liu, Zhenzhen [1 ,2 ]
Qiu, Xiaozhang [1 ,2 ]
Tan, Xuhua [1 ,2 ,3 ]
Luo, Lixia [1 ,2 ,3 ]
Liu, Yizhi [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
关键词
axial length; cataract; intraocular lens calculation; prediction accuracy; silicone oil-filled eyes; INTRAOCULAR-LENS CALCULATION; REMOVAL; CATARACT; FORMULA; BIOMETRY;
D O I
10.1111/aos.16627
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine whether correcting the axial length (AL) measurement error of the IOLMaster 700 could improve the refractive prediction accuracy in silicone oil-filled eyes.Methods This study included 265 cataract patients (265 eyes) with silicone oil tamponade who were scheduled for phacoemulsification with intraocular lens (IOL) implantation. The performances of various formulas, including Barrett Universal II, Emmetropia Verifying Optical, Hoffer-QST, Kane, Ladas Super Formula, Pearl-DGS, Radial Basis Function and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T), were evaluated. The refractive prediction errors (PE) calculated with measured AL (AL(meas)) and corrected AL with silicone oil adjustment (SOAL) were compared. Subgroup analysis was performed based on the AL(meas) (<23 mm; 23-26 mm; >= 26 mm).Results Using SOAL significantly reduced the hyperopic PE of formulas when compared to AL(meas) (-0.05 to 0.17 D vs 0.15 to 0.38 D, p < 0.001). After applying AL correction, all formulas showed a lower mean absolute PE (0.47-0.57 D vs 0.50-0.69 D). The percentage of eyes within +/- 1.0 D of PE increased from 84.91%-88.68% to 89.81%-91.32% for new formulas and from 78.11%-83.40% to 85.66%-88.68% for traditional formulas, with the use of SOAL. Subgroup analysis showed that the majority of formulas with SOAL in prediction accuracy for eyes with an AL >= 26 mm (p < 0.05).Conclusions The refractive prediction accuracy in silicone oil-filled eyes was improved by correcting the AL measurement error of the IOLMaster 700, especially for long eyes.
引用
收藏
页码:e718 / e726
页数:9
相关论文
共 28 条
  • [21] Axial length measurements before and after removal of silicone oil: a new method to correct the axial length of silicone-filled eyes for optical biometry
    Wang, Kai
    Yuan, Meng-Ke
    Jiang, Yan-Rong
    Bao, Yong-Zhen
    Li, Xiao-Xin
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (04) : 449 - 457
  • [22] Validation of axial length optimization as a way to improve refractive prediction error after cataract surgery
    Mayer, Jason R.
    Landis, Zachary
    Patel, Ravi
    Weller, Christopher
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [23] Accuracy of segmented measurement of axial length in ultra-high myopia filled with silicone oil using immersion B-scan ultrasonography
    Qing-Hua Yang
    Hong-Tao Zhang
    Xiao-Qi Li
    Bing Chen
    Zhao-Hui Li
    Yi-Fei Huang
    Xin Jin
    Ying Zhang
    Li-Qiang Wang
    International Journal of Ophthalmology, 2022, (05) : 793 - 799
  • [24] Accuracy of segmented measurement of axial length in ultra-high myopia filled with silicone oil using immersion B-scan ultrasonography
    Yang, Qing-Hua
    Zhang, Hong-Tao
    Li, Xiao-Qi
    Chen, Bing
    Li, Zhao-Hui
    Huang, Yi-Fei
    Jin, Xin
    Zhang, Ying
    Wang, Li-Qiang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (05) : 793 - 799
  • [25] Accuracy of using the axial length of the fellow eye for IOL calculation in retinal detachment eyes undergoing silicone oil removal
    Lwowski, Christoph
    Kaiser, Klemens Paul
    Bucur, Julian
    Schicho, Philipp
    Kohnen, Thomas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (07) : 921 - 926
  • [26] Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using X ray computed tomography
    Takei, K
    Sekine, Y
    Okamoto, F
    Hommura, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (01) : 47 - 50
  • [27] Comments on “Effects of refractive accommodation on subfoveal choroidal thickness in silicone oil-filled eyes” BMC Ophthalmology (2022) 22:107 https://doi.org/10.1186/s12886-022-02332-y
    Lei Gao
    Yang Zhou
    Guangsen Liu
    BMC Ophthalmology, 22
  • [28] Comments on "Effects of refractive accommodation on subfoveal choroidal thickness in silicone oil-filled eyes" BMC Ophthalmology (2022) 22:107 https://doi.org/10.1186/s12886-022-02332-y
    Gao, Lei
    Zhou, Yang
    Liu, Guangsen
    BMC OPHTHALMOLOGY, 2022, 22 (01)