Overall cooling characteristics of double-wall effusion system considering material selections and hole arrangements

被引:7
|
作者
Gu, Huaduo [1 ]
Zhou, Deli [1 ]
Du, Kun [2 ]
Li, Weihong [1 ,3 ]
机构
[1] City Univ Hong Kong, Dept Mech Engn, Hong Kong 999077, Peoples R China
[2] Northwestern Polytech Univ, Sch Power & Energy, Xian, Peoples R China
[3] City Univ Hong Kong, Shenzhen Res Inst, Ctr Adv Struct Mat, Shenzhen 518057, Peoples R China
基金
中国国家自然科学基金;
关键词
Gas turbine cooling; Double-wall effusion system; Conjugate heat transfer; Material thermal conductivity; Backward film injection; LOCAL HEAT/MASS TRANSFER; CONJUGATE HEAT-TRANSFER; SPENT FLUID REMOVAL; IMPINGING JETS; TARGET SURFACE; VENT HOLES; ARRAYS; PLATE;
D O I
10.1016/j.ijheatmasstransfer.2023.124599
中图分类号
O414.1 [热力学];
学科分类号
摘要
Enhancing thermal protection of hot components in gas turbines can be accomplished using advanced materials with various thermal conductivities and optimized cooling structures that exhibit high internal-external cooling efficiency. The double-wall effusion system (DWES) stands out as a promising solution for effectively cooling gas turbine hot components. However, its thermal response to new materials remains inadequately explored, and the combined effect of hole arrangement and thermal conductivity within the DWES system has not been thoroughly investigated. In this study, the impacts of material selection and hole arrangement on the overall cooling characteristics of the impingement-pinfin-effusion based DWES were thoroughly investigated. Three different materials with varying thermal conductivities were selected to control Biot number, and various hole arrangements, including effusion-only or impingement-effusion, as well as forward or backward film injection, were compared to quantify the contributions of internal and film cooling on the overall cooling performance. The results showed that the stainless-steel scheme achieves the highest overall cooling effectiveness due to its superior thermal conductivity, while the polycarbonate scheme obtains the lowest overall cooling effectiveness. Compared to the corresponding effusion-only schemes, the area-averaged overall cooling effectiveness of the stainless-steel impingement-effusion scheme demonstrates a remarkable increase of up to 29%. Notably, employing backward film injection yields remarkable improvements in overall cooling effectiveness, with the stainless-steel impingement-effusion scheme exhibiting an increment of up to 16% compared to the forward film injection configuration. Furthermore, the correlations that establish the relationship between the overall cooling effectiveness, Biot number, and blowing ratio were developed for various configurations. These correlations can serve as valuable design tools for the development of next-generation gas turbines that incorporate the DWES technology.
引用
收藏
页数:12
相关论文
共 48 条
  • [41] Numerical Investigation of the Effects of the Hole Inclination Angle and Blowing Ratio on the Characteristics of Cooling and Stress in an Impingement/Effusion Cooling System
    Li, Haiwang
    Zhang, Dawei
    You, Ruquan
    Zou, Yifan
    Liu, Song
    ENERGIES, 2023, 16 (02)
  • [42] Effects of Area Ratio of Film Hole to Impingement Hole and Momentum Flux Ratio on Overall Cooling Effectiveness of Afterburner Double Wall Heat Shield
    Niu J.-J.
    Liu C.-L.
    Liu H.-Y.
    Xiao X.
    Lin J.-F.
    Tuijin Jishu/Journal of Propulsion Technology, 2021, 42 (03): : 601 - 611
  • [43] Study on the flow and heat transfer characteristics of a double-wall structure with multiple-jet impingement cooling under rotating conditions
    You, Ruquan
    Liu, Zexuan
    Wang, Qinqin
    Li, Haiwang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 161
  • [44] EFFECTS OF EFFUSION COOLING PATTERN NEAR THE DILUTION HOLE FOR A DOUBLE-WALLED COMBUSTOR LINER-PART 1: OVERALL EFFECTIVENESS MEASUREMENTS
    Shrager, Adam C.
    Thole, Karen A.
    Mongillo, Dominic
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2018, VOL 5C, 2018, : 133 - 144
  • [45] Effects of Effusion Cooling Pattern Near the Dilution Hole for a Double-Walled Combustor Liner-Part 1: Overall Effectiveness Measurements
    Shrager, Adam C.
    Thole, Karen A.
    Mongillo, Dominic
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2019, 141 (01):
  • [46] Thermal characteristics of a double-glazed external wall system with roll screen in cooling season
    Tanaka, Hiroaki
    Okumiya, Masaya
    Tanaka, Hideki
    Yoon, Gyu Young
    Watanabe, Kenji
    BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1509 - 1516
  • [47] Experimental and numerical studies on the enhanced heat transfer performance and the flow resistance characteristics of the double-wall cooling structure with jet impingement holes and pin fins
    Wei, Hong
    Zu, Yingqing
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 186
  • [48] Numerical simulation of composite swirl/film double-wall cooling structures and chamber designs for enhanced overall cooling effectiveness: II. Improvement with serpentine chamber and application in C3X vane
    Han, Shaohua
    Xiang, Zhen
    Qi, Shizhen
    Jia, Yibin
    Guo, Tairan
    An, Na
    Liu, Qilong
    Huo, Tianyi
    Xing, Jiangjiang
    Zhang, Runsheng
    Zhou, Leping
    Li, Li
    Zhang, Hui
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 234