Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis

被引:2
|
作者
Vaz, Gilvan Ferreira [1 ,2 ]
Freire, Felipe Florencio [2 ]
Goncalves, Henrique Mansur M. [3 ]
de Aviz, Marcus Alexandre Brito M. [4 ]
Martins, Wagner Rodrigues M. [1 ]
Durigan, Joao Luiz Quagliotti M. [1 ,5 ]
机构
[1] Univ Brasilia, Fac Ceilandia, Rehabil Sci Program, Brasilia, DF, Brazil
[2] Hosp Forcas Armadas HFA, Dept Orthopaed, Med Div, Brasilia, DF, Brazil
[3] Santa Helena Hosp, Orthoped Dept, Brasilia, DF, Brazil
[4] Inst Hosp Base, Anesthesiol Dept, Brasilia, DF, Brazil
[5] Univ Brasilia, Fac Ceilandia, Rehabil Sci Program, Lab Muscle & Tendon Plast, Brasilia, DF, Brazil
来源
PLOS ONE | 2023年 / 18卷 / 06期
关键词
EXTREMITY MUSCLE STRENGTH; KNEE; ARTHRITIS; OUTCOMES; HEALTHY; WOMAC;
D O I
10.1371/journal.pone.0278086
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
IntroductionThe handheld dynamometer has been validated to measure muscle strength in different muscle groups. However, to date, it has not been tested in individuals who experience pain induced by hip osteoarthritis. The current study aimed to evaluate the intra- and inter-rater reliability, agreement, and minimal detectable change of the Lafayette handheld dynamometer, model 1165, to assess the peak force (Pk) and average peak force (Af) of hip muscles in individuals with symptomatic hip osteoarthritis. MethodsTwenty participants with hip osteoarthritis (mean +/- SD age: 58.7 +/- 15.3 years; body mass index: 28.8 +/- 4.2 kg/m(2)) and pain intensity on the Visual Analogue Scale >= 4 (8.05 +/- 1.2) were recruited to participate in this study. Pk and Af of hip flexors (seated position), abductors and adductors (supine position), and extensors (prone position) were collected in a single day by two independent raters, each one obtaining test and retest in randomly ordered separate sessions. ResultsThe intra-rater intraclass correlation coefficient (ICC) was classified as good (>0.75) or excellent (>= 0.90) for all muscle groups and all inter-rater ICCs were classified as excellent. Rater A had a lower standard error of measurement compared to rater B, ranging from 0.15 to 0.58 kilogram-force (Kgf) compared with 0.34 to 1.25 kg, respectively. However, the inter-rater comparison showed a minimal detectable change (MDC) of < 10% for all Pk and Af measures for hip adductors and extensors. Finally, the inter-rater Bland-Altman analysis demonstrated good agreement for abductors, adductors, and extensors. ConclusionDespite pain and dysfunction related to hip osteoarthritis, the mean of two measures using a handheld dynamometer was shown to be a reliable tool to assess hip muscle strength, with good to excellent intra- and inter-rater ICCs, satisfactory agreement, and small values for MDC.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Intra- and inter-rater reliability of the manual method of measuring respiratory muscle coordination
    Rodrigues, Antenor
    Xiong, Yijun
    Telias, Irene
    Goligher, Ewan
    Brochard, Laurent
    Reid, W. Darlene
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [42] Intra- and inter-rater reliability for judgement of cough following citric acid inhalation
    Miles, Anna
    Huckabee, Maggie-Lee
    INTERNATIONAL JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2013, 15 (02) : 209 - 215
  • [43] Development, intra- and inter-rater reliability of the New Zealand Secretion Scale (NZSS)
    Miles, Anna
    Hunting, Alexandra
    INTERNATIONAL JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2019, 21 (04) : 377 - 384
  • [44] Intra- and Inter-Rater Reliability of Three Measurements for Assessing Tactile Acuity in Individuals with Chronic Low Back Pain
    Wang, Juan
    Chen, Changcheng
    Peng, Mengsi
    Wang, Yizu
    Wu, Bao
    Zheng, Yili
    Wang, Xueqiang
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2020, 2020
  • [45] Measurement of lumbar lordosis: Inter-rater reliability, minimum detectable change and longitudinal variation
    Hicks, Gregory E.
    George, Steven Z.
    Nevitt, Michael A.
    Cauley, Jane A.
    Vogt, Molly T.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (07): : 501 - 506
  • [46] Using standardized scales to assess fear at veterinary visits: Intra- and inter-rater reliability
    Mercier, Pierrette
    Honeckman, Lynn
    Jokela, Fiia
    Dunham, Arthur E.
    Overall, Karen L.
    JOURNAL OF VETERINARY BEHAVIOR-CLINICAL APPLICATIONS AND RESEARCH, 2023, 62 : 12 - 17
  • [47] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA) IN HEALTHY PARTICIPANTS
    Stanek, Justin M.
    Smith, Joshua
    Petrie, Jake
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2019, 14 (01): : 107 - 116
  • [48] Intra- and Inter-Rater Reliability of the Infant Motor Profile in Infants in Primary Health Care
    Tveten, Kine Melfald
    Hadders-Algra, Mijna
    Strand, Liv Inger
    Van Iersel, Patricia Anna Maria
    Rieber, Jannike
    Dragesund, Tove
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2020, 40 (05) : 571 - 581
  • [49] Intra- and inter-rater reliability of goniometric finger range of motion using a written protocol
    Nakai, Takuya
    Amano, Satoru
    Murao, Chikako
    Taguchi, Haruki
    Takahashi, Kayoko
    ARCHIVES OF PHYSIOTHERAPY, 2024, 14 (01) : 83 - 88
  • [50] Intra- and inter-rater reliability of post-void residual bladder volume with ultrasound
    Juliana Falcão Padilha
    Jordana Barbosa da Silva
    Enio Júnior Seidel
    Patricia Driusso
    International Urogynecology Journal, 2020, 31 : 973 - 979