Cooling performance of radiant air conditioning with an infrared-transparent membrane

被引:3
|
作者
Wang, Fang [1 ]
Zhao, Xinke [1 ]
Pang, Dongqing [1 ]
Li, Zhiqiang [1 ]
Liu, Mengwei [1 ]
Du, Weifeng [1 ]
Zhang, Yichi [1 ]
Guo, Wenliang [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
关键词
Dew-point temperature; Radiative heat transfer; Convective heat transfer; Radiant heat-transfer ratio; Surface temperature; Infrared-transparent membrane; VENTILATION; SYSTEMS; ROOM;
D O I
10.1016/j.enbuild.2023.113124
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In view of the problems that the surface of radiant air conditioning is prone to condensation and the cooling capacity is limited by the dew-point temperature, a model for radiant air conditioning with an infrared -transparent membrane has been developed which installs an infrared-transparent membrane vertically below the radiant cooling plate of a radiant air conditioner to form a closed gas interlayer between them. On the basis of this, the effects of the gas type (vacuum, nitrogen, air, argon, and carbon dioxide) and relative air humidity in the interlayer on the radiative heat transfer, convective heat transfer, and radiative heat-transfer ratio of the radiant cooling plate, and the surface temperature of the infrared-transparent membrane were investigated by CFD (Computational Fluid Dynamics) numerical simulation. When the thickness and gas type of the interlayer were 20 mm and vacuum, respectively, the radiant cooling plate showed the most radiative heat transfer, the least convective heat transfer, the largest radiative heat-transfer ratio, and the highest surface temperature of the membrane, followed by when the gas type was argon. There was no risk of condensation in the air conditioning when the relative air humidity in the interlayer did not exceed 80%. The results of the study provide a theoretical basis for the optimal design of radiant air conditioners.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Membrane-assisted radiant cooling for expanding thermal comfort zones globally without air conditioning
    Teitelbaum, Eric
    Chen, Kian Wee
    Aviv, Dorit
    Bradford, Kipp
    Ruefenacht, Lea
    Sheppard, Denon
    Teitelbaum, Megan
    Meggers, Forrest
    Pantelic, Jovan
    Rysanek, Adam
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (35) : 21162 - 21169
  • [22] INFRARED-TRANSPARENT CONVECTION SHIELDS FOR RADIATIVE COOLING - INITIAL RESULTS ON CORRUGATED POLYETHYLENE FOILS
    NILSSON, NA
    ERIKSSON, TS
    GRANQVIST, CG
    SOLAR ENERGY MATERIALS, 1985, 12 (05): : 327 - 333
  • [23] Infrared-transparent glass ceramics: An exploratory study
    McCloy, John S.
    Riley, Brian J.
    Pierce, David A.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2015, 410 : 160 - 173
  • [24] Cooling performance test and analysis of a radiant-convective air conditioning terminal device with parallel pipes
    Shu Hiawen
    Shi Jing
    Wang Tingyu
    Wang Hongbin
    Lin, Duanmu
    8TH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2016, 146 : 127 - 132
  • [25] Refractive index of infrared-transparent polycrystalline alumina
    Harris, Daniel C.
    Johnson, Linda F.
    Cambrea, Lee
    Baldwin, Lawrence
    Baronowski, Meghan
    Zelmon, David E.
    Poston, William B.
    Kunkel, John D.
    Parish, Mark
    Pascucci, Marina R.
    Gannon, John J., Jr.
    Wen, Tzu-Chien
    OPTICAL ENGINEERING, 2017, 56 (07)
  • [26] Refractive Index of Infrared-Transparent Polycrystalline Alumina
    Harris, Daniel C.
    Johnson, Linda F.
    Cambrea, Lee R.
    Baldwin, Lawrence
    Baronowski, Meghan
    Zelmon, David E.
    Poston, William B.
    Kunkel, John D.
    Parish, Mark
    Pascucci, Marina R.
    Gannon, John J., Jr.
    Wen, Tzu-Chien
    WINDOW AND DOME TECHNOLOGIES AND MATERIALS XV, 2017, 10179
  • [27] Temperature Regulation in Colored Infrared-Transparent Polyethylene Textiles
    Cai, Lili
    Peng, Yucan
    Xu, Jinwei
    Zhou, Chenyu
    Zhou, Chenxing
    Wu, Peilin
    Lin, Dingchang
    Fan, Shanhui
    Cui, Yi
    JOULE, 2019, 3 (06) : 1478 - 1486
  • [28] Cooling performance test and analysis of a radiant-convective air-conditioning terminal device with parallel pipes
    Shu Haiwen
    Wang Tingyu
    Shi Jing
    Wang Hongbin
    Duanmu Lin
    Zhu Mingrui
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (03) : 405 - 412
  • [29] Decoupling Control on Air-conditioning System with Combined Radiant Cooling and Independent Fresh air
    Tan, Yongguang
    Yue, Shihong
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 337 - +
  • [30] Research on thermodynamic performance of a novel building cooling system integrating dew point evaporative cooling, air-carrying energy radiant air conditioning and vacuum membrane-based dehumidification (DAV-cooling system)
    Chun, Liang
    Gong, Guangcai
    Peng, Pei
    Wan, Yangda
    Chua, Kian Jon
    Fang, Xi
    Li, Wenqiang
    ENERGY CONVERSION AND MANAGEMENT, 2021, 245