An ultrasensitive dual-signal ratio electrochemical aptamer biosensor for the detection of HER2

被引:6
|
作者
Zhang, Ya [1 ]
Xu, Ying [1 ]
Li, Ning [1 ]
Qi, Na [1 ]
Peng, Lan [2 ]
Yang, Mei [1 ]
Hou, Changjun [1 ,4 ]
Huo, Danqun [1 ,3 ]
机构
[1] Chongqing Univ, Bioengn Coll, Key Lab Biorheol Sci & Technol, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Med & Pharmaceut Coll, Basic Dept, Chongqing 401331, Peoples R China
[3] Chongqing Univ, Sch Microelect & Commun Engn, Chongqing Key Lab Biopercept & Intelligent Informa, Chongqing 400044, Peoples R China
[4] Shanghai Jiao Tong Univ, Natl Facil Translat Med, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
HER2; Ratiometric strategy; Electrochemical aptasensor; Cu; UiO-66 @TMB; ZIF-67 @PDA; BREAST-CANCER; LIQUID BIOPSY;
D O I
10.1016/j.colsurfb.2022.113118
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrochemical ratiometric biosensors have received attention from researchers because of their self-calibration capability, which can improve the accuracy of detection. In the present study, a ratiometric dual signal electrochemical aptamer biosensor based on ZIF-67 @polydopamine (PDA) nanocomposite and Cu/UiO-66 @ 3, 3 ', 5, 5 '-tetramethylbenzidine (TMB) nanocomposite was fabricated for the detection of breast cancer biomarkerhuman epidermal growth factor receptor 2 (HER2). PDA was chosen as the electroactive material with electrochemical redox activity and ZIF-67 with a high specific surface area, forming the ZIF-67 @PDA+Apt as the nanoprobe for capturing HER2 in this paper. Cu/UiO-66 is a bimetallic compound with high stability, specific surface area, and strong adsorption onto aptamer chains, and the Cu/UiO-66 @TMB+Apt nanocomposite was used as a probe for signal labeling. In the presence of HER2, the capture of HER2 by the ZIF-67 @PDA+Apt probe results in a weakening of the conductivity of the electrode, however, by attenuating the electrochemical signal from the PDA, altering the probe-Cu/UiO-66 @TMB+Apt signaling will result in the enhancement of the TMB electrochemical signal. With a sensitive detection of HER2 biomarkers in as little as 30 min with the detection range of 0.75-40 pg/mL and a limit of detection as low as 44.8 fg/mL. Dual signal ratio biosensors have a low limit of detection, short detection time, which can accurately detect targets in complex biological samples, which has important theoretical importance.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Rolling Circle Amplification/G-Quadruplex-Based Dual-Signal Ratiometric Electrochemical Aptasensor for Ultrasensitive Detection of Pathogenic Bacteria
    Ding, Zishan
    Yang, Sha
    Wang, Jue
    Zhao, Zhuyang
    Xu, Hanqing
    Chen, Zhiguo
    Liu, Zhiyong
    Wang, Yunxia
    Bao, Jing
    Chang, Kai
    Chen, Ming
    CHEMELECTROCHEM, 2023, 10 (17)
  • [22] Dual-Signal Amplification Strategy for Ultrasensitive Photoelectrochemical Immunosensing of α-Fetoprotein
    Li, Yong-Jie
    Ma, Meng-Jie
    Zhu, Jun-Jie
    ANALYTICAL CHEMISTRY, 2012, 84 (23) : 10492 - 10499
  • [23] A sensitive determination of albumin in urine by molecularly imprinted electrochemical biosensor based on dual-signal strategy
    Zhang, Guihua
    Yu, Ying
    Guo, Manli
    Lin, Bixia
    Zhang, Li
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 564 - 570
  • [24] A dual signal amplification-assisted DNAzyme biosensor for ultrasensitive detection of Argonaute 2 activity
    Zhang, Dandan
    Ma, Fei
    Leng, Junhong
    Zhang, Chun-yang
    CHEMICAL COMMUNICATIONS, 2018, 54 (97) : 13678 - 13681
  • [25] Ultrasensitive Biomimetic Skin with Multimodal and Photoelectric Dual-Signal Sensing
    Gao, Han
    Cai, Wenshan
    Li, Aotian
    Du, Yike
    Zhu, Ji-Liang
    Ye, Zhicheng
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (16) : 21073 - 21083
  • [26] Ultrasensitive direct impedimetric immunosensor for detection of serum HER2
    Sharma, Shikha
    Zapatero-Rodriguez, Julia
    Saxena, Rahul
    O'Kennedy, Richard
    Srivastava, Sudha
    BIOSENSORS & BIOELECTRONICS, 2018, 106 : 78 - 85
  • [27] A dual-signal aptasensor based on cascade amplification for ultrasensitive detection of aflatoxin B1
    Zhu, Fang
    Zhang, Hu
    Wu, Ruoxi
    Lu, Yanyan
    Wang, Jin
    Ravikumar, A.
    Selvan, G. Tamil
    Zhu, Nuanfei
    Zhang, Zhen
    Tang, Jun
    BIOSENSORS & BIOELECTRONICS, 2024, 250
  • [28] Ultrasensitive Detection of DNA via SI-eRAFT and in Situ Metalization Dual-Signal Amplification
    Sun, Haobo
    Xu, Wen
    Liu, Bang
    Liu, Qianrui
    Wang, Qangwei
    Li, Lianzhi
    Kong, Jinming
    Zhang, Xueji
    ANALYTICAL CHEMISTRY, 2019, 91 (14) : 9198 - 9205
  • [29] Mechanochromic Optical/Electrical Skin for Ultrasensitive Dual-Signal Sensing
    Zhang, Heng
    Chen, Haomin
    Lee, Jeng-Hun
    Kim, Eunyoung
    Chan, Kit-Ying
    Venkatesan, Harun
    Shen, Xi
    Yang, Jinglei
    Kim, Jang-Kyo
    ACS NANO, 2023, 17 (06) : 5921 - 5934
  • [30] An aptamer biosensor based dual signal amplification system for the detection of salmonella typhimurium
    Li, Ao
    Zuo, Peng
    Ye, Bang-Ce
    ANALYTICAL BIOCHEMISTRY, 2021, 615