Efficient Design of Remote Field Eddy Current Array Probe for Imaging of Defects in Small Diameter Ferromagnetic Tube

被引:0
|
作者
Vijayachandrika, T. [1 ]
Thirunavukkarasu, S. [1 ]
Kumar, Anish [1 ]
机构
[1] A CI Homi Bhabha Natl Inst, Indira Gandhi Ctr Atom Res, Met & Mat Grp, Nondestruct Evaluat Div, Kalpakkam 603102, Tamil Nadu, India
关键词
RFEC; array probe; imaging; finite element model; optimization; INSPECTION;
D O I
10.3233/SAEM230010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Array probe design is challenging in remote field eddy current (RFEC) technique due to the exciter and receiver separation. This paper presents the design of a multi-element RFECarray probe for imaging of defects in ferromagnetic steam generator tubes. Systematic investigations of the axial and radial magnetic field distribution at the remote zone are performed to understand their detection sensitivity. The radial magnetic field, showed higher perturbation near defect and hence higher sensitivity. Hence, receiver coiloriented in the radial direction is chosen for the array probe. Further optimization of the number of radial type receiver coils,diameter, height, and angular distance between the coils are carried out after systematic investigations with experimental studies and verified with model results. An array probe with eightnumbers of 4 mm x 4 mm (diameter and height) radial receiver coils placed at 45 degrees apart in the circumferential direction is found to be optimum to detect a1.2 mm diameter through hole. The performance of the radial receiver coil is encouraging for enhanced detection of defects and design of array probe.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [21] A new array eddy current testing probe for inspection of small-diameter tubes in Tokamak fusion devices
    Zhao, Yingsong
    Qi, Pan
    Xie, Zheng
    Bai, Peigen
    Chen, Hong-En
    Xie, Shejuan
    Liao, Shusheng
    Chen, Zhenmao
    FUSION ENGINEERING AND DESIGN, 2020, 157
  • [22] REMOTE-FIELD EDDY-CURRENT SIGNAL ANALYSIS IN SMALL-BORE FERROMAGNETIC TUBES
    MACKINTOSH, DD
    ATHERTON, DL
    SULLIVAN, SP
    MATERIALS EVALUATION, 1993, 51 (04) : 492 - 495
  • [24] Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars
    Han, Lei
    Jiang, Yi
    Yuan, Ming
    Sensors, 2024, 24 (24)
  • [25] Eddy Current Probe With Integrated Tunnel Magnetoresistance Array Sensors for Tube Inspection
    Tao, Yu
    Peng, Lei
    Li, Xiaoguang
    Ye, Chaofeng
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (05)
  • [26] A remote field eddy current NDT probe for the inspection of metallic plates
    Sun, Y.S.
    Udpa, S.
    Lord, William
    Cooley, D.
    1996, American Society for Nondestructive Testing (54)
  • [27] A remote field eddy current NDT probe for the inspection of metallic plates
    Sun, YS
    Udpa, S
    Lord, W
    Cooley, D
    MATERIALS EVALUATION, 1996, 54 (04) : 510 - 512
  • [28] IMPROVEMENT IN REMOTE-FIELD EDDY-CURRENT PROBE STRUCTURE
    SUN, YS
    QU, MX
    SI, JT
    LU, CT
    ZHOU, XY
    ATHERTON, DL
    MATERIALS EVALUATION, 1992, 50 (05) : 600 - &
  • [29] Application of a superconductor to the shield of a remote field eddy current testing probe
    Yusa, N
    Demachi, K
    Chen, ZM
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2004, 19 (1-4) : 41 - 46
  • [30] THE EFFECT OF AN EXTERNAL TUBE ON THE REMOTE FIELD EDDY-CURRENT EFFECT
    SULLIVAN, S
    ATHERTON, DL
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1989, 31 (10): : 547 - 550