Midterm follow-up after embolization of intracranial aneurysms proximal to the circle of Willis with the Silk Vista flow diverter: the I-MAMA registry

被引:0
|
作者
Da Ros, Valerio [1 ]
Sabuzi, Federico [1 ]
D'Argento, Francesco [2 ]
Pedicelli, Alessandro [2 ]
Gavrilovic, Vladimir [3 ]
Sponza, Massimo [3 ]
Di Giuliano, Francesca [1 ]
Biraschi, Francesco [4 ]
Iacobucci, Marta [4 ]
Grillea, Giovanni [5 ]
Bartolo, Andrea [5 ]
Patassini, Mirko [6 ]
Remida, Paolo [6 ]
Quilici, Luca [7 ]
Farago, Giuseppe [7 ]
Varrassi, Marco [8 ]
Cavasin, Nicola [9 ]
Arpesani, Roberto [10 ]
Giordano, Aldo Victor [8 ]
Umana, Giuseppe [11 ]
Garaci, Francesco [1 ]
Floris, Roberto [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Biomed & Prevent, Diagnost Imaging Unit, Rome, Italy
[2] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOSD Neuroradiol Interventist, Largo A Gemelli 8, I-00168 Rome, Italy
[3] Udine Univ Hosp, Div Vasc & Intervent Radiol, I-33100 Udine, Italy
[4] Sapienza Univ Rome, Dept Human Neurosci, Intervent Neuroradiol, Policlin Umberto 1, Rome, Italy
[5] Ist Ricovero & Cura Carattere Sci IRCCS Neuromed, UOC Neuroradiol Diagnost & Terapeut, Pozzilli, IS, Italy
[6] Osped San Gerardo, Struttura Complessa Neuroradiol, ASST, Monza, Italy
[7] AAST Osped Papa Giovanni XXIII, Dept Neuroradiol, Bergamo, Italy
[8] S Salvatore Hosp, Radiol Dept, Laquila, Italy
[9] Osped Dell Angelo Mestre, Neuroradiol, Venice, Italy
[10] Spedali Riuniti Livorno, Intervent Radiol Unit, Livorno, Italy
[11] Cannizzaro Hosp, Dept Neurosurg, Catania, Italy
关键词
Aneurysm; Embolization; Flow diverter; Subarachnoid haemorrhage; EMPHASIS;
D O I
10.1007/s00234-024-03336-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this registry was to assess technical success, procedural safety and mid- to long-term follow-up results of the Silk Vista "Mama" (SVM) flow diverter (BALT, Montmorency, France) for the treatment of proximal intracranial aneurysms. Methods Between August 2020 and March 2022, data from nine Italian neurovascular centres were collected. Data included patients' clinical presentation, aneurysms' size, location and status, technical details, overall complications and mid- to long-term angiographic follow-up. Results Forty-eight aneurysms in 48 patients were treated using the SVM. Most aneurysms were small (<= 10 mm: no. 29, 60%) and unruptured (no. 31, 65%); 13 aneurysms were recurrent after coiling or clipping. 37/48 aneurysms involved the internal carotid artery (77%). Optimal opening and complete wall apposition of the device were achieved in 46 out of 48 cases (96%). Four intra- or periprocedural complications occurred (two thrombotic complications successfully resolved, one cerebellar ischemia, one perirenal hematoma), without new neurological deficit. No significant intra-stent stenosis or stent displacement was observed during follow-up. No FD-related morbidity nor mortality was reported. At midterm (6-12 months) to long-term (> 12 months) follow-up, complete aneurysm occlusion (OKM D) was achieved in 76% of cases. Eighty-eight percent of patients had complete aneurysm occlusion or entry remnant (OKM D + C). Conclusions Our experience suggests that the new generation of low-profile SVM flow diverter for the treatment of proximal intracranial aneurysms is safe and effective, with low rates of intraprocedural complications and acceptable mid- to long-term occlusion rate.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 39 条
  • [21] Cost-Effectiveness Analytic Comparison of Follow-up Strategies after Pipeline Embolization Device Treatment of Intracranial Aneurysms
    Salem, Mohamed
    Salem, Mohamed
    Salih, Mira
    Nwajei, Felix
    Gomez-Paz, Santiago
    Thomas, Ajith
    Ogilvy, Christopher
    Moore, Justin
    [J]. JOURNAL OF NEUROSURGERY, 2021, 135 (02) : 11 - 11
  • [22] Long-term follow-up in the endovascular treatment of intracranial aneurysms with flow-diverter stents: update of a single-centre experience
    Giuseppe Guzzardi
    Carmelo Stanca
    Paolo Cerini
    Bruno Del Sette
    Ignazio Divenuto
    Emanuele Malatesta
    Alessandro Carriero
    Alessandro Stecco
    [J]. La radiologia medica, 2018, 123 : 449 - 455
  • [23] Long-term follow-up in the endovascular treatment of intracranial aneurysms with flow-diverter stents: update of a single-centre experience
    Guzzardi, Giuseppe
    Stanca, Carmelo
    Cerini, Paolo
    Del Sette, Bruno
    Divenuto, Ignazio
    Malatesta, Emanuele
    Carriero, Alessandro
    Stecco, Alessandro
    [J]. RADIOLOGIA MEDICA, 2018, 123 (06): : 449 - 455
  • [24] Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single Center
    Deutschmann, H. A.
    Wehrschuetz, M.
    Augustin, M.
    Niederkorn, K.
    Klein, G. E.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (03) : 481 - 486
  • [25] Spanish Registry for Embolization of Small Intracranial Aneurysms with Cerecyte Coils (SPAREC) Study Early Experience and Mid-Term Follow-up Results
    Castro, E.
    Villoria, F.
    Castano, C.
    Romance, A.
    Mendez, J. C.
    Barrena, R.
    Fortea, F.
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2008, 14 (04): : 375 - 384
  • [26] Cost-Effectiveness Analytic Comparison of Neuroimaging Follow-Up Strategies After Pipeline Embolization Device Treatment of Unruptured Intracranial Aneurysms
    Salem, Mohamed M.
    Salih, Mira
    Nwajei, Felix
    Gomez-Paz, Santiago
    Thomas, Ajith J.
    Ogilvy, Christopher S.
    Moore, Justin M.
    [J]. WORLD NEUROSURGERY, 2022, 158 : E206 - E213
  • [27] Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study
    Dinc, Hasan
    Saatci, Isil
    Oguz, Sukru
    Baltacioglu, Feyyaz
    Yildiz, Altan
    Donmez, Halil
    Belet, Umit
    Onal, Baran
    Andic, Cagatay
    Koc, Osman
    Kocak, Omer
    Koroglu, Mert
    Cetin, Mustafa
    Cekirge, H. Saruhan
    [J]. NEURORADIOLOGY, 2021, 63 (06) : 943 - 952
  • [28] Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study
    Hasan Dinc
    Isil Saatci
    Sukru Oguz
    Feyyaz Baltacioglu
    Altan Yildiz
    Halil Donmez
    Umit Belet
    Baran Onal
    Cagatay Andic
    Osman Koc
    Omer Kocak
    Mert Koroglu
    Mustafa Cetin
    H.Saruhan Cekirge
    [J]. Neuroradiology, 2021, 63 : 943 - 952
  • [29] Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms
    John, Seby
    Bain, Mark D.
    Hui, Ferdinand K.
    Hussain, M. Shazam
    Masaryk, Thomas J.
    Rasmussen, Peter A.
    Toth, Gabor
    [J]. NEUROSURGERY, 2016, 78 (06) : 862 - 867
  • [30] Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: complications, aneurysm sac occlusion, reabsorption, recurrence, and jailed branch modification at follow-up
    Michelozzi, Caterina
    Darcourt, Jean
    Guenego, Adrien
    Januel, Anne-Christine
    Tall, Philippe
    Gawlitza, Matthias
    Bonneville, Fabrice
    Cognard, Christophe
    [J]. JOURNAL OF NEUROSURGERY, 2019, 131 (06) : 1751 - 1762