Midterm follow-up after embolization of intracranial aneurysms proximal to the circle of Willis with the Silk Vista flow diverter: the I-MAMA registry

被引:0
|
作者
Da Ros, Valerio [1 ]
Sabuzi, Federico [1 ]
D'Argento, Francesco [2 ]
Pedicelli, Alessandro [2 ]
Gavrilovic, Vladimir [3 ]
Sponza, Massimo [3 ]
Di Giuliano, Francesca [1 ]
Biraschi, Francesco [4 ]
Iacobucci, Marta [4 ]
Grillea, Giovanni [5 ]
Bartolo, Andrea [5 ]
Patassini, Mirko [6 ]
Remida, Paolo [6 ]
Quilici, Luca [7 ]
Farago, Giuseppe [7 ]
Varrassi, Marco [8 ]
Cavasin, Nicola [9 ]
Arpesani, Roberto [10 ]
Giordano, Aldo Victor [8 ]
Umana, Giuseppe [11 ]
Garaci, Francesco [1 ]
Floris, Roberto [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Biomed & Prevent, Diagnost Imaging Unit, Rome, Italy
[2] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOSD Neuroradiol Interventist, Largo A Gemelli 8, I-00168 Rome, Italy
[3] Udine Univ Hosp, Div Vasc & Intervent Radiol, I-33100 Udine, Italy
[4] Sapienza Univ Rome, Dept Human Neurosci, Intervent Neuroradiol, Policlin Umberto 1, Rome, Italy
[5] Ist Ricovero & Cura Carattere Sci IRCCS Neuromed, UOC Neuroradiol Diagnost & Terapeut, Pozzilli, IS, Italy
[6] Osped San Gerardo, Struttura Complessa Neuroradiol, ASST, Monza, Italy
[7] AAST Osped Papa Giovanni XXIII, Dept Neuroradiol, Bergamo, Italy
[8] S Salvatore Hosp, Radiol Dept, Laquila, Italy
[9] Osped Dell Angelo Mestre, Neuroradiol, Venice, Italy
[10] Spedali Riuniti Livorno, Intervent Radiol Unit, Livorno, Italy
[11] Cannizzaro Hosp, Dept Neurosurg, Catania, Italy
关键词
Aneurysm; Embolization; Flow diverter; Subarachnoid haemorrhage; EMPHASIS;
D O I
10.1007/s00234-024-03336-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aim of this registry was to assess technical success, procedural safety and mid- to long-term follow-up results of the Silk Vista "Mama" (SVM) flow diverter (BALT, Montmorency, France) for the treatment of proximal intracranial aneurysms. Methods Between August 2020 and March 2022, data from nine Italian neurovascular centres were collected. Data included patients' clinical presentation, aneurysms' size, location and status, technical details, overall complications and mid- to long-term angiographic follow-up. Results Forty-eight aneurysms in 48 patients were treated using the SVM. Most aneurysms were small (<= 10 mm: no. 29, 60%) and unruptured (no. 31, 65%); 13 aneurysms were recurrent after coiling or clipping. 37/48 aneurysms involved the internal carotid artery (77%). Optimal opening and complete wall apposition of the device were achieved in 46 out of 48 cases (96%). Four intra- or periprocedural complications occurred (two thrombotic complications successfully resolved, one cerebellar ischemia, one perirenal hematoma), without new neurological deficit. No significant intra-stent stenosis or stent displacement was observed during follow-up. No FD-related morbidity nor mortality was reported. At midterm (6-12 months) to long-term (> 12 months) follow-up, complete aneurysm occlusion (OKM D) was achieved in 76% of cases. Eighty-eight percent of patients had complete aneurysm occlusion or entry remnant (OKM D + C). Conclusions Our experience suggests that the new generation of low-profile SVM flow diverter for the treatment of proximal intracranial aneurysms is safe and effective, with low rates of intraprocedural complications and acceptable mid- to long-term occlusion rate.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 39 条
  • [1] Treatment of Intracranial Aneurysms Using the New Silk Vista Flow Diverter: Safety Outcomes at Short-Term Follow-Up
    Pumar, Jose M.
    Mosqueira, Antonio
    Olier, Jorge
    Rodriguez-Fernandez, Claudio
    Vega, Pedro
    Gonzalez-Diaz, Eva
    [J]. FRONTIERS IN NEUROLOGY, 2021, 12
  • [2] Early experience and midterm follow-up results of Spanish registry for embolization of intracranial aneurysms with cerecyte coils (SPAREC study)
    Castro, Enrique
    Fortea, Fernando
    Castano, Carlos
    Villoria, Francisco
    [J]. STROKE, 2007, 38 (02) : 594 - 594
  • [3] Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study
    Berge, J.
    Biondi, A.
    Machi, P.
    Brunel, H.
    Pierot, L.
    Gabrillargues, J.
    Kadziolka, K.
    Barreau, X.
    Dousset, V.
    Bonafe, A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1150 - 1155
  • [4] Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study
    Foa Torres, G.
    Roca, F.
    Noguera, A.
    Godes, J.
    Petrocelli, S.
    Aznar, I.
    Ales, S.
    Muszynski, P.
    Maehara, R.
    Vicente, M.
    Pumar, J. M.
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (04) : 357 - 362
  • [5] Endovascular Treatment of Intracranial Aneurysms in Small Peripheral Vessel Segments-Efficacy and Intermediate Follow-Up Results of Flow Diversion With the Silk Vista Baby Low-Profile Flow Diverter
    Schuengel, Marie-Sophie
    Quaeschling, Ulf
    Weber, Erik
    Struck, Manuel Florian
    Maybaum, Jens
    Bailis, Nikolaos
    Arlt, Felix
    Richter, Cindy
    Hoffmann, Karl-Titus
    Scherlach, Cordula
    Schob, Stefan
    [J]. FRONTIERS IN NEUROLOGY, 2021, 12
  • [6] Morphologic and Clinical Outcome of Intracranial Aneurysms after Treatment Using Flow Diverter Devices: Mid-Term Follow-Up
    Breu, Anna-Katharina
    Hauser, Till-Karsten
    Ebner, Florian H.
    Bischof, Felix
    Ernemann, Ulrike
    Seeger, Achim
    [J]. RADIOLOGY RESEARCH AND PRACTICE, 2016, 2016
  • [7] 3-Year Follow-Up after Endovascular Aneurysm Treatment with Silk® Flow Diverter
    Ringelstein, A.
    Schlamann, M.
    Goericke, S. L.
    Moenninghoff, C.
    Sandalcioglu, I. E.
    El Hindy, N.
    Forsting, M.
    Wanke, I.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (04): : 328 - 332
  • [8] Predictors for ophthalmic segment aneurysms recanalization after coiling and flow diverter embolization in 6-and 12-month follow-up
    Wisniewski, Karol
    Tomasik, Bartlomiej
    Bobeff, Ernest J.
    Stefanczyk, Ludomir
    Hupalo, Marlena
    Jaskolski, Dariusz J.
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 68 : 151 - 157
  • [9] Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience
    Piano, Mariangela
    Valvassori, Luca
    Quilici, Luca
    Pero, Guglielmo
    Boccardi, Edoardo
    [J]. JOURNAL OF NEUROSURGERY, 2013, 118 (02) : 408 - 416
  • [10] Long-term follow-up of the DERIVO® Embolization Device (DED®) for intracranial aneurysms: the Italian Multicentric Registry
    Piano, Mariangela
    Lozupone, Emilio
    Sgoifo, Annalisa
    Nuzzi, Nunzio P.
    Asteggiano, Francesco
    Pero, Guglielmo
    Quilici, Luca
    Iannucci, Giuseppe
    Cerini, Paolo
    Comelli, Chiara
    Peschillo, Simone
    Princiotta, Ciro
    Pedicelli, Alessandro
    Limbucci, Nicola
    Ganci, Giuseppe
    Trasimeni, Guido
    Ciceri, Elisa
    Farago, Giuseppe
    Giorgianni, Andrea
    De Nicola, Maurizio
    Remida, Paolo
    Lafe, Elvis
    Mardighian, Dikran
    Ruggiero, Maria
    Lazzarotti, Guido A.
    Cavasin, Nicola
    Castellan, Lucio
    Chiumarulo, Luigi
    Burdi, Nicola
    Paolucci, Aldo
    Briganti, Francesco
    Natrella, Massimiliano
    Florio, Francesco P.
    Pavia, Marco
    Gallesio, Ivan
    Lucente, Giuseppe
    Gozzoli, Luigi
    Caputo, Nevia
    Vagnarelli, Simone
    Boccardi, Edoardo
    Valvassori, Luca
    [J]. JOURNAL OF NEUROSURGICAL SCIENCES, 2021, 65 (03) : 361 - 368