Coupling Effect on Unbalanced Voltages and Power Under Faulty Condition in Triple Three-Phase Wind Power Generators

被引:3
|
作者
Wu, Lijian [1 ]
Wang, Wenting [1 ]
Lyu, Zekai [1 ]
Zhong, Yunlong [2 ]
Liu, Jiaming [2 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
[2] Shanghai Elect Wind Power Grp Co Ltd, Hangzhou 310027, Peoples R China
关键词
Magnetic coupling; permanent magnet (PM) wind power generator; transformer; triple three-phase; DIRECT-DRIVE;
D O I
10.1109/TIE.2023.3262881
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In wind power generation, generators with multiple independent three-phase winding sets grow in popularity owing to their fault-tolerant capability. Nevertheless, when one three-phase channel malfunctions and is disconnected, it is found in this article that unbalanced voltages and output power occur under such a faulty condition in triple three-phase (TTP) generators. The reason is revealed to be the magnetic coupling between winding sets (WSs). By analogy with the transformer effect, an equivalent circuit model is built to investigate the coupling effect. Furthermore, the influence of factors such as the current angle, electric loading, and mutual inductances are discussed. When all three WSs operate, the currents of each WS can be regarded as shifted by a leading and lagging angle, respectively. Due to symmetry, these two effects cancel out in healthy operation. However, under faulty condition, only the leading effect still exists for one WS and the lagging effect for the other WS, resulting in the stated imbalance. Finally, experiments on a TTP machine validate the theoretical analysis.
引用
收藏
页码:1308 / 1318
页数:11
相关论文
共 50 条
  • [1] Three-phase active power filter under unbalanced condition
    Lin, BR
    Huang, CH
    Yang, ZZ
    [J]. 2005 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), VOLS 1-6, CONFERENCE PROCEEDINGS, 2005, : 3647 - 3650
  • [2] Dynamic Power Decoupling Strategy for Three-Phase PV Power Systems Under Unbalanced Grid Voltages
    Tang, Cheng-Yu
    Kao, Li-Huan
    Chen, Yaow-Ming
    Ou, Sheng-Yuan
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (02) : 540 - 548
  • [3] Stationary frame deadbeat power control of three-phase PWM rectifiers under unbalanced grid voltages
    Chen, Wei
    Geng, Xiujie
    Liu, Tao
    Xia, Changliang
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 : 223 - 233
  • [4] Implementation of a three-phase capacitor-clamped active power filter under unbalanced condition
    Lin, Bor-Ren
    Huang, Chun-Hao
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1621 - 1630
  • [5] Direct Power Control for Three-Phase Power Converters under Distorted Input Voltages
    Vazquez, S.
    Sanchez, J. A.
    Carrasco, J. M.
    Galvan, E.
    Leon, J. I.
    Dominguez, E.
    Martinez, O.
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 1256 - +
  • [6] Reconstructed Phase Voltages Based Power Following Control for Three-Phase Buck Rectifier Under Unbalanced Phase Voltages and Wide AC Input Frequency
    Huang, Rui
    Xu, Jianping
    Chen, Qiang
    Guo, Xia
    Cao, Haibin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2022 - 2031
  • [7] Control of Three-phase Cascaded Multilevel Converter Based Power Electronic Transformer under Unbalanced Input Voltages
    Li, Houzhi
    Wang, Yubin
    Yu, Chenghao
    [J]. PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 3299 - 3304
  • [8] Power Supply Capability Evaluation for Unbalanced Three-phase Distribution Network With Distributed Generators
    Zhao, Jinquan
    Huang, Bing
    Zhu, Bin
    Su, Dawei
    Wu, Haiwei
    [J]. 2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [9] An Intelligent Wind Farm Model for Three-phase Unbalanced Power Flow Studies
    Opathella, C.
    Cheng, D.
    Venkatesh, B.
    [J]. 2014 4TH INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGY AND TECHNOPRENEURSHIP (ICE2T), 2014, : 99 - 104
  • [10] A novel three-phase active power filter control algorithm with unbalanced and distorted supply voltages
    Mishra, Mahesh K.
    Karthikeyan, K.
    [J]. TENCON 2005 - 2005 IEEE REGION 10 CONFERENCE, VOLS 1-5, 2006, : 2533 - +