A capacitor clamped voltage source inverter for active power filter operation under the balance and unbalance conditions is proposed to suppress current harmonics and compensate the reactive power generated from the nonlinear loads. Two control loops are used in the control scheme to achieve harmonic and reactive currents compensation and to regulate the inverter dc side voltage. In the adopted inverter, the neutral point voltage is compensated by a voltage compensator to obtain the balanced capacitor voltages on the de side. The balanced and sinusoidal line currents are drawn from the ac source under the balanced and unbalanced conditions. The feasibility of the proposed scheme is confirmed through experimental results.
引用
收藏
页码:3647 / 3650
页数:4
相关论文
共 50 条
  • [1] Implementation of a three-phase capacitor-clamped active power filter under unbalanced condition
    Lin, Bor-Ren
    Huang, Chun-Hao
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1621 - 1630
  • [2] Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
    Chelli, Z.
    Toufouti, R.
    Omeiri, A.
    Saad, S.
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2015, 2015
  • [3] Research on control strategy for three-phase three-wire shunt active power filter under unbalanced loads
    Wei, Xue-liang
    Dai, Ke
    Peng, Hua-liang
    Kang, Yong
    Chen, Jian
    EUROCON 2007: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOLS 1-6, 2007, : 372 - 376
  • [4] Control scheme for three-phase three-wire shunt active power filter with unbalanced loads
    Wei, Xue-Liang
    Dai, Ke
    Xie, Bin
    Kang, Yong
    Peng, Hua-Liang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (24): : 64 - 69
  • [5] Three-Phase Shunt Active Power Filter Control with Line Current Sensing Only, Under Unbalanced Loading Conditions
    Hekimoglu, B.
    Cakir, M.
    Abut, N.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (04): : 1398 - 1404
  • [6] A novel three-phase active power filter control algorithm with unbalanced and distorted supply voltages
    Mishra, Mahesh K.
    Karthikeyan, K.
    TENCON 2005 - 2005 IEEE REGION 10 CONFERENCE, VOLS 1-5, 2006, : 2533 - +
  • [7] Three-Phase For-Wire Shunt Active Filter With Unbalanced loads
    Mahni, T.
    Benchouia, M. T.
    Srairi, K.
    Ghamri, A.
    Golea, A.
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 528 - 535
  • [8] Performance analysis of three-phase three-wire shunt active power filter compensating for unbalanced loads
    Wei, XueLiang
    Dai, Ke
    Lei, Qin
    Xiang, Dong
    Kang, Yong
    Luo, Fang
    Zhu, Guorong
    IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, : 1875 - +
  • [9] A Novel Shunt Active Power Filter Under Condition of Unbalanced Voltage
    Xi, Ziqiang
    Xin, Zhanqiang
    Zhou, Shiping
    Huang, Wencong
    Qi, Lei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [10] Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads
    Dixon, JW
    Garcia, JJ
    Moran, L
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1995, 42 (06) : 636 - 641