Experimental and numerical study of thermal coupling on catalyst-coated membrane for proton exchange membrane water electrolyzer

被引:5
|
作者
Su, Chao [1 ]
Chen, Zhidong [1 ]
Wu, Zexuan [1 ]
Zhang, Jing [1 ]
Li, Kaiyang [1 ]
Hao, Junhong [1 ]
Kong, Yanqiang [1 ]
Zhang, Naiqiang [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Minist Educ, Key Lab Power Stn Energy Transfer Convers & Syst, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane water electrolyzer; Catalyst-coated membrane; Thermal coupling characteristic; Experimental analysis; Multiphysics field; FLEXIBLE MICRO-SENSORS; PEM FUEL-CELL; TEMPERATURE DISTRIBUTION; SIMULATION; FLOW; PERFORMANCE; HEAT; MASS; MEA;
D O I
10.1016/j.apenergy.2023.122442
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
During the long-term operation of proton exchange membrane water electrolyzers (PEMWEs), Formation of localized hotspots in the catalyst-coated membrane (CCM) will seriously threaten the safe and efficient operation of the electrolyzer. This paper adopts a combination of dynamic experiments and numerical simulation analysis, aiming to develop the in-situ characterization technology of the thermal characteristics as well as the theoretical analysis of the multiphysics field for the & sdot;PEMWE. Based on both experimental and theoretical results, it is concluded that: (1) The high current density leads to an extremely uneven temperature distribution on the surface of the CCM. High temperature difference (as high as 34.04 degrees C) and high local temperature (up to 98.08 degrees C) are observed; (2) 30-50% of the electrical energy during the electrolyzer is converted into heat, of which the polarization heat accounts for the major part, followed by proton-conductive Joule heat; (3) The accumulation of gas phase during the transfer process of gas-liquid two phases is the primary cause of the deterioration of heat transfer, which further leads to local overheating. This study provides an experimental and theoretical basis for the safe and efficient operation of proton exchange membrane water electrolysis technology.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Single cell performance of catalyst coated membrane based on superthin proton exchange membrane
    Mu, Shichun
    Cheng, Niancai
    Zhao, Pei
    Cheng, Lei
    Pan, Mu
    Yuan, Runzhang
    Proceedings of the 4th International Conference on Fuel Cell Science, Engineering, and Technology, Pts A and B, 2006, : 329 - 331
  • [42] Enabling low-IrO2 2 proton exchange membrane water electrolysis via microporous layer-supported catalyst-coated membranes
    Hansen, Kentaro U.
    Lee, Ahryeon
    Jiao, Feng
    CHEM CATALYSIS, 2024, 4 (07):
  • [43] A cocrystallized catalyst-coated membrane with high performance for solid polymer electrolyte water electrolysis
    Wang, Xunying
    Shao, Zhi-Gang
    Li, Guangfu
    Zhang, Linsong
    Zhao, Yun
    Lu, Wangting
    Yi, Baolian
    JOURNAL OF POWER SOURCES, 2013, 240 : 525 - 529
  • [44] Directly coated membrane electrode assemblies for proton exchange membrane water electrolysis
    Holzapfel, Peter
    Buehler, Melanie
    Chuyen Van Pham
    Hegge, Friedemann
    Boehm, Thomas
    McLaughlin, David
    Breitwieser, Matthias
    Thiele, Simon
    ELECTROCHEMISTRY COMMUNICATIONS, 2020, 110
  • [45] Recent progress in understanding the dispersion stability of catalyst ink for proton exchange membrane fuel cell and water electrolyzer
    Murugaiah, Dhinesh Kumar
    Shahgaldi, Samaneh
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 66 : 156 - 169
  • [46] Effect of Catalyst Ink Properties on the Performance of Proton Exchange Membrane Fuel Cell and Water Electrolyzer: A Mini Review
    Choi, Won-Jong
    Kang, Inku
    Yu, Duk Man
    Yoon, Sang Jun
    So, Soonyong
    Oh, Keun-Hwan
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [47] A bibliometric study on the research trends and hotspots of proton exchange membrane electrolyzer
    Zou, Long
    Xu, Lingyi
    Jiang, Ziheng
    Liao, Jiadong
    Gao, Pengyun
    Yang, Guogang
    Li, Shian
    Shen, Qiuwan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (03):
  • [48] Experimental Validation of an Equivalent Dynamic Electrical Model for a Proton Exchange Membrane Electrolyzer
    Guilbert, Damien
    Vitale, Gianpaolo
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [49] Integrated ultra-low PtIr catalyst coated membrane toward efficient proton exchange membrane water electrolyzers
    Qin, Jiaqi
    Lv, Yang
    Han, Guangqi
    Liu, Huiyuan
    Li, Yongpeng
    Zhang, Hongyan
    Zhou, Xiaoyu
    Xing, Keran
    Li, Tiantian
    Sun, Chongyun
    Wang, Chunxiao
    Zhou, Qiang
    Wu, Ren'an
    Wang, Dongqi
    Song, Yujiang
    CHEMICAL ENGINEERING JOURNAL, 2024, 479
  • [50] Direct kinetic loss analysis with hierarchy configuration of catalyst coated membrane in proton exchange membrane water electrolysis cell
    He, Yunlong
    Feng, Suyang
    Chen, Hui
    Liu, Yun
    Shi, Xiaodong
    Rao, Peng
    Li, Jing
    Wu, Xiao
    Huang, Shuyi
    Li, Ke
    Wang, Hao
    Tian, Xinlong
    Kang, Zhenye
    Fuel, 2025, 379