Experimental and numerical study of thermal coupling on catalyst-coated membrane for proton exchange membrane water electrolyzer

被引:5
|
作者
Su, Chao [1 ]
Chen, Zhidong [1 ]
Wu, Zexuan [1 ]
Zhang, Jing [1 ]
Li, Kaiyang [1 ]
Hao, Junhong [1 ]
Kong, Yanqiang [1 ]
Zhang, Naiqiang [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Minist Educ, Key Lab Power Stn Energy Transfer Convers & Syst, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane water electrolyzer; Catalyst-coated membrane; Thermal coupling characteristic; Experimental analysis; Multiphysics field; FLEXIBLE MICRO-SENSORS; PEM FUEL-CELL; TEMPERATURE DISTRIBUTION; SIMULATION; FLOW; PERFORMANCE; HEAT; MASS; MEA;
D O I
10.1016/j.apenergy.2023.122442
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
During the long-term operation of proton exchange membrane water electrolyzers (PEMWEs), Formation of localized hotspots in the catalyst-coated membrane (CCM) will seriously threaten the safe and efficient operation of the electrolyzer. This paper adopts a combination of dynamic experiments and numerical simulation analysis, aiming to develop the in-situ characterization technology of the thermal characteristics as well as the theoretical analysis of the multiphysics field for the & sdot;PEMWE. Based on both experimental and theoretical results, it is concluded that: (1) The high current density leads to an extremely uneven temperature distribution on the surface of the CCM. High temperature difference (as high as 34.04 degrees C) and high local temperature (up to 98.08 degrees C) are observed; (2) 30-50% of the electrical energy during the electrolyzer is converted into heat, of which the polarization heat accounts for the major part, followed by proton-conductive Joule heat; (3) The accumulation of gas phase during the transfer process of gas-liquid two phases is the primary cause of the deterioration of heat transfer, which further leads to local overheating. This study provides an experimental and theoretical basis for the safe and efficient operation of proton exchange membrane water electrolysis technology.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Experimental Study on the Catalyst-Coated Membrane of a Proton Exchange Membrane Electrolyzer
    Rocha, Amadeu Gomes
    Ferreira, Rui
    Falcao, Daniela
    Pinto, Alexandra M. F. R.
    ENERGIES, 2022, 15 (21)
  • [2] Study on corrosion migrations within catalyst-coated membranes of proton exchange membrane electrolyzer cells
    Mo, Jingke
    Steen, Stuart
    Kang, Zhenye
    Yang, Gaoqiang
    Taylor, Derrick A.
    Li, Yifan
    Toops, Todd J.
    Brady, Michael P.
    Retterer, Scott T.
    Cullen, David A.
    Green, Johney B., Jr.
    Zhang, Feng-Yuan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (44) : 27343 - 27349
  • [3] Optimization of catalyst-coated membranes for enhancing performance in proton exchange membrane electrolyzer cells
    Xie, Zhiqiang
    Yu, Shule
    Yang, Gaoqiang
    Li, Kui
    Ding, Lei
    Wang, Weitian
    Zhang, Feng-Yuan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (01) : 1155 - 1162
  • [4] An improved catalyst-coated membrane structure for PEM water electrolyzer
    Song, Shidong
    Zhang, Huamin
    Liu, Bo
    Zhao, Ping
    Zhang, Yining
    Yi, Baolian
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2007, 10 (08) : B122 - B125
  • [5] Catalyst-coated proton exchange membrane for hydrogen production with high pressure water electrolysis
    Zhang, Xinrong
    Zhang, Wei
    Yang, Weijing
    Liu, Wen
    Min, Fanqi
    Mao, Samuel S.
    Xie, Jingying
    APPLIED PHYSICS LETTERS, 2021, 119 (12) : 1ENG
  • [6] Numerical study of proton exchange membrane water electrolyzer performance based on catalyst layer agglomerate model
    Xu, Mingyi
    Li, Jingde
    Qin, Yanzhou
    Wang, Yanji
    Du, Xiaohang
    Liu, Guihua
    Chemical Engineering Journal, 2024, 499
  • [7] Experimental and Numerical Study on Thermal Conductivity of Proton Exchange Membrane
    Chen, Lei
    Zhang, Hu
    Li, Zhong-Zhen
    He, Ya-Ling
    Tao, Wen-Quan
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2015, 15 (04) : 3087 - 3091
  • [8] Numerical simulation of gradient catalyst layer design in proton exchange membrane water electrolyzer with enhanced performance
    Li, Guangze
    Xu, Mingyi
    Qin, Yanzhou
    Zhang, Yongguang
    Wang, Yanji
    Yu, Xiong
    Li, Jingde
    FUEL, 2024, 368
  • [9] Investigation on the proton exchange membrane water electrolyzer using supported anode catalyst
    Sui, Sheng
    Ma, Lirong
    Zhai, Yuchun
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2009, 4 (01): : 8 - 11
  • [10] Progress in the proton exchange membrane for PEM water electrolyzer
    Yu, Jun (yujun@whut.edu.cn), 1600, Materials China (36):