Refrigerant Selection for Heat Pumps: The Compressor Makes the Difference

被引:2
|
作者
Neumaier, Lisa [1 ]
Roskosch, Dennis [1 ]
Schilling, Johannes [1 ]
Bauer, Gernot [2 ]
Gross, Joachim [2 ]
Bardow, Andre [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Energy & Proc Syst Engn, Tannenstr 3, CH-8092 Zurich, Switzerland
[2] Univ Stuttgart, Inst Tech Thermodynam & Thermal Proc Engn, Pfaffenwaldring 9, D-70569 Stuttgart, Germany
关键词
compressor model; computer-aided molecular designs; heat pumps; PC-SAFT equation of state; piston compressor; refrigerant screening; RECIPROCATING-COMPRESSORS; THERMODYNAMIC EVALUATION; FLUID SELECTION; PERFORMANCE; EQUATION; DESIGN; STATE;
D O I
10.1002/ente.202201403
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Increasingly stringent regulations and new applications require selecting improved refrigerants for heat pumps. The selected refrigerants should be environmentally friendly and maximize the performance of the heat pump process. Systematic refrigerant selection methods usually model the compressor with one fixed isentropic efficiency identical for all refrigerants. However, compressor studies indicate that the isentropic efficiency may be highly refrigerant-dependent. Herein, the need for a refrigerant-dependent compressor model for refrigerant selection is investigated. For this purpose, a refrigerant-dependent compressor model is combined with an integrated design of refrigerant and heat pump process. To guarantee a comparable nominal heating power among refrigerants, the compressor design is tailored to the refrigerant by expanding the refrigerant-dependent compressor model toward compressor sizing. Integrating compressor design into systematic refrigerant selection is enabled by a computationally efficient model implementation. Accounting for refrigerant-dependent compression substantially changes the resulting refrigerant ranking compared to the widely used assumption of identical isentropic efficiencies for all refrigerants: The best-performing refrigerant is not even identified among the best ten refrigerants when assuming identical isentropic efficiencies. Consequently, compression is identified as the main driver for differences in refrigerant performance. Therefore, integrating refrigerant-dependent compressor models is crucial for systematic refrigerant selection.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Investigation of the Interactions between Refrigerant, Flowsheet, and Compressor in Residential Heat Pumps
    Hoeges, Christoph
    Roskosch, Dennis
    Brach, Jona
    Vering, Christian
    Venzik, Valerius
    Mueller, Dirk
    ENERGY TECHNOLOGY, 2023, 11 (02)
  • [2] Refrigerant Selection for District Heating's Large-scale Heat Pumps
    Balyaligil, Görkem
    Euroheat and Power (English Edition), 2024, 2024 (03): : 14 - 18
  • [3] COMPRESSOR EFFICIENCY - DEFINITION MAKES A DIFFERENCE
    LADY, ER
    CHEMICAL ENGINEERING, 1970, 77 (17) : 113 - &
  • [4] Towards an integral decision-making process applied to the refrigerant selection in heat pumps
    Vering, Christian
    Kroppa, Hendrik
    Venzik, Valerius
    Streblow, Rita
    Mueller, Dirk
    RENEWABLE ENERGY, 2022, 192 : 815 - 827
  • [5] Testing of refrigerant mixtures in residential heat pumps
    Electric Power Research Institute, (Report) EPRI TR, 1996, (105394s):
  • [6] A NEW CONCEPT OF REFRIGERANT CONTROL FOR HEAT PUMPS
    HARNISH, JR
    IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1966, IGA2 (06): : 485 - &
  • [7] Material selection makes a difference
    Goodrich, BF
    CHEMICAL ENGINEERING, 1997, 104 (10) : 221 - 221
  • [8] BINARY REFRIGERANT MIXTURES FOR COMPRESSION HEAT-PUMPS
    SCHNITZER, H
    BERNTSSON, T
    BRENNSTOFF-WARME-KRAFT, 1985, 37 (1-2): : 55 - 59
  • [9] Binary Refrigerant Mixtures for Compression Heat Pumps.
    Schnitzer, H.
    Berntsson, Th.
    Brennstoff-Waerme-Kraft, 1985, 37 (1-2): : 55 - 59
  • [10] Test of a reciprocating compressor for ammonia heat pumps
    Hivet, B
    Arzano, C
    Ducruet, C
    Braendgaard, T
    APPLICATIONS FOR NATURAL REFRIGERANTS, 1996, : 233 - 240