Analytical Validation of a Spiral Microfluidic Chip with Hydrofoil-Shaped Pillars for the Enrichment of Circulating Tumor Cells

被引:3
|
作者
Sen-Dogan, Begum [1 ]
Demir, Mehmet Alper [1 ]
Sahin, Buket [1 ]
Yildirim, Ender [1 ,2 ,3 ]
Karayalcin, Gizem [1 ]
Sahin, Sebnem [1 ]
Mutlu, Ege [1 ]
Toral, Taylan Berkin [1 ]
Ozgur, Ebru [1 ]
Zorlu, Ozge [1 ]
Kulah, Haluk [1 ,3 ,4 ]
机构
[1] Mikro Biyosistemler AS, TR-06530 Ankara, Turkiye
[2] Middle East Tech Univ, Dept Mech Engn, TR-06800 Ankara, Turkiye
[3] METU MEMS Ctr, TR-06530 Ankara, Turkiye
[4] Middle East Tech Univ, Dept Elect & Elect Engn, TR-06800 Ankara, Turkiye
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 10期
关键词
microfluidic channel; computational fluid dynamics; circulating tumor cell (CTC) separation; inertial hydrodynamics; LABEL-FREE ISOLATION; ULTRA-FAST; SEPARATION; PARTICLES;
D O I
10.3390/bios13100938
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The isolation of circulating tumor cells (CTCs) from peripheral blood with high efficiency remains a challenge hindering the utilization of CTC enrichment methods in clinical practice. Here, we propose a microfluidic channel design for the size-based hydrodynamic enrichment of CTCs from blood in an epitope-independent and high-throughput manner. The microfluidic channel comprises a spiral-shaped part followed by a widening part, incorporating successive streamlined pillars, that improves the enrichment efficiency. The design was tested against two benchmark designs, a spiral microfluidic channel and a spiral microfluidic channel followed by a widening channel without the hydrofoils, by processing 5 mL of healthy blood samples spiked with 100 MCF-7 cells. The results proved that the design with hydrofoil-shaped pillars perform significantly better in terms of recovery (recovery rate of 67.9% compared to 23.6% in spiral and 56.7% in spiral with widening section), at a cost of slightly lower white blood cell (WBC) depletion (depletion rate of 94.2% compared to 98.6% in spiral and 94.2% in spiral with widening section), at 1500 mu L/min flow rate. For analytical validation, the design was further tested with A549, SKOV-3, and BT-474 cell lines, yielding recovery rates of 62.3 +/- 8.4%, 71.0 +/- 6.5%, and 82.9 +/- 9.9%, respectively. The results are consistent with the size and deformability variation in the respective cell lines, where the increasing size and decreasing deformability affect the recovery rate in a positive manner. The analysis before and after the microfluidic chip process showed that the process does not affect cell viability.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Wedge-shaped microfluidic chip for circulating tumor cells isolation and its clinical significance in gastric cancer
    Chaogang Yang
    Nangang Zhang
    Shuyi Wang
    Dongdong Shi
    Chunxiao Zhang
    Kan Liu
    Bin Xiong
    Journal of Translational Medicine, 16
  • [22] Wedge-shaped microfluidic chip for circulating tumor cells isolation and its clinical significance in gastric cancer
    Yang, Chaogang
    Zhang, Nangang
    Wang, Shuyi
    Shi, Dongdong
    Zhang, Chunxiao
    Liu, Kan
    Xiong, Bin
    JOURNAL OF TRANSLATIONAL MEDICINE, 2018, 16
  • [23] Microfluidic capillary-array filter for enrichment of circulating tumor cells
    Szelig, A. G.
    Ivan, K.
    Kosa, B.
    Kurdi, C.
    Koszegi, T.
    Laki, A. J.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 13 - 13
  • [24] Clinical Validation of an Ultra High-Throughput Spiral Microfluidics for the Detection and Enrichment of Viable Circulating Tumor Cells
    Khoo, Bee Luan
    Warkiani, Majid Ebrahimi
    Tan, Daniel Shao-Weng
    Bhagat, Ali Asgar S.
    Irwin, Darryl
    Lau, Dawn Pingxi
    Lim, Alvin S. T.
    Lim, Kiat Hon
    Krisna, Sai Sakktee
    Lim, Wan-Teck
    Yap, Yoon Sim
    Lee, Soo Chin
    Soo, Ross A.
    Han, Jongyoon
    Lim, Chwee Teck
    PLOS ONE, 2014, 9 (07):
  • [25] A Simple Fabricated Microfluidic Chip for Rapid Capture of Circulating Tumor Cells
    Gao Juyi
    Du Jinghui
    Zhang Wang
    Zhang Baoyue
    Liu Zongbin
    Chen Yan
    Xu Xiaoping
    ACTA CHIMICA SINICA, 2014, 72 (01) : 69 - 74
  • [26] Capturing and Clinical Applications of Circulating Tumor Cells with Wave Microfluidic Chip
    Chen, Hongmei
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 190 (04) : 1470 - 1483
  • [27] Capturing and Clinical Applications of Circulating Tumor Cells with Wave Microfluidic Chip
    Hongmei Chen
    Applied Biochemistry and Biotechnology, 2020, 190 : 1470 - 1483
  • [28] 3D-Stacked Multistage Inertial Microfluidic Chip for High-Throughput Enrichment of Circulating Tumor Cells
    Xu, X.
    Huang, X.
    Sun, J.
    Chen, J.
    Wu, G.
    Yao, Y.
    Zhou, N.
    Wang, S.
    Sun, L.
    CYBORG AND BIONIC SYSTEMS, 2022, 2022
  • [29] Clinical Microfluidic Chip Platform for the Isolation of Versatile Circulating Tumor Cells
    Chen, Hongmei
    Han, Yufeng
    Li, Qingli
    Zou, Yong
    Wang, Shuangshou
    Jiao, Xiaodong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):
  • [30] Spiral shape microfluidic channel for selective isolating of heterogenic circulating tumor cells
    Kwak, Bongseop
    Lee, Jeonghun
    Lee, Jaehun
    Kim, Hyun Soo
    Kang, Shinwon
    Lee, Yongkoo
    BIOSENSORS & BIOELECTRONICS, 2018, 101 : 311 - 316