Experiment and performance evaluation of an integrated low-temperature proton exchange membrane fuel cell system with an absorption chiller

被引:4
|
作者
Wang, Hanbin [1 ,2 ]
Luo, Chunhuan [1 ,2 ]
Zhang, Rudan [1 ,2 ]
Li, Yongsheng [1 ,2 ]
Yang, Changchang [1 ,2 ]
Li, Zexiang [1 ,2 ]
Li, Jianhao [1 ,2 ]
Li, Na [3 ]
Li, Yiqun [4 ]
Su, Qingquan [1 ,2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Energy & Environm Engn, 30 Xueyuan Rd, Beijing 100083, Peoples R China
[2] Beijing Key Lab Energy Conservat & Emiss Reduct Me, Beijing 100083, Peoples R China
[3] State Grid Corp China, Beijing 100083, Peoples R China
[4] Anhui Polytech Univ, Sch Elect Engn, 8 Beijing Middle Rd, Wuhu 241000, Anhui, Peoples R China
关键词
Low-temperature proton exchange membrane; fuel cell; Absorption chiller; Integrated system; Waste heat recovery; Performance evaluation; HEAT-PUMP CYCLE; THERMODYNAMIC PROPERTIES; POWER-SYSTEM; ENERGY; REFRIGERATION; OPTIMIZATION; CATALYST; DESIGN; PEMFC;
D O I
10.1016/j.renene.2023.118937
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When the typical operation temperature of the Proton Exchange Membrane Fuel Cell (PEMFC) reaches 333.15-363.15 K, the ratio of electrical energy to waste heat generated by the PEMFC is about 1. In this paper, an absorption chiller with LiBr/[BMIM]Cl/CH3OH as the working pair is proposed to convert the waste heat into cooling capacity. The PEMFC and absorption chiller (AC) systems have been studied from the energy and effi-ciency point of view. The COP of the integrated system can reach a maximum of 0.85, which is remarkably 0.35 higher than that of the individual PEMFCs. The electrochemical process of the PEMFC and the thermodynamic process of the AC systems are calculated using MATLAB. The results show that the PEMFC operation temperature of 353.15-358.15K is sufficient to drive the AC and meet the requirement of 273.15-283.15K evaporation temperature and 308.15-313.15K condensation temperature. Meanwhile, when the electric power output from the PEMFC is 100 kW, the AC can output approximately 60 kW cooling capacity, which is sufficient to meet the cooling demand of the commercial bus.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Thermal analysis of high-temperature proton exchange membrane fuel cell integrated compression-assisted absorption heat pump system
    Liang, Yu
    Zhang, Xiao
    Cai, Liang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 147 : 91 - 105
  • [32] Performance of a proton exchange membrane fuel cell stack
    Johnson, R
    Morgan, C
    Witmer, D
    Johnson, T
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2001, 26 (08) : 879 - 887
  • [33] Ecological Performance Analysis of an Integrated Proton Exchange Membrane Fuel Cell and Thermoelectric Devices
    Huang, Yuewu
    Ding, Hui
    Zou, Yufei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (03): : 2581 - 2593
  • [34] Performance of a proton exchange membrane fuel cell stack
    Johnson, R.
    Morgan, C.
    Witmer, D.
    Johnson, T.
    International Journal of Non-Linear Mechanics, 2001, 36 (08) : 879 - 887
  • [35] Analysis of proton exchange membrane fuel cell performance with a new generation of proton exchange membrane
    Hu, J
    Zhou, LR
    Zhu, Y
    Li, W
    Li, Z
    Niu, SP
    Lu, L
    Zhang, WX
    He, Y
    HYDROGEN ENERGY PROGRESS XIII, VOLS 1 AND 2, PROCEEDINGS, 2000, : 821 - 825
  • [36] Design and performance evaluation of power system for unmanned ship based on proton exchange membrane fuel cell
    Wu, Jiawen
    Cai, Shanshan
    Guan, Yin
    Li, Song
    Tu, Zhengkai
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 59 : 730 - 741
  • [37] Performance investigation on the bypass ejector for a proton exchange membrane fuel cell system
    Han, Jiquan
    Besagni, Giorgio
    Mereu, Riccardo
    Inzoli, Fabio
    Feng, Jianmei
    Peng, Xueyuan
    APPLIED THERMAL ENGINEERING, 2024, 241
  • [38] Effect of carbon black concentration in carbon fiber paper on the performance of low-temperature proton exchange membrane fuel cells
    Liu, Ching-Han
    Ko, Tse-Hao
    Liao, Yuan-Kai
    JOURNAL OF POWER SOURCES, 2008, 178 (01) : 80 - 85
  • [39] Proton exchange membrane fuel cell from low temperature to high temperature: Material challenges
    Shao, Yuyan
    Yin, Geping
    Wang, Zhenbo
    Gao, Yunzhi
    JOURNAL OF POWER SOURCES, 2007, 167 (02) : 235 - 242
  • [40] Integrated Energy System Based on Reversible Proton Exchange Membrane Fuel Cell and Expander
    He L.
    Wang K.
    Cao G.
    Zhai B.
    Li G.
    Zhang X.
    Zhang, Xiongwen, 1600, Xi'an Jiaotong University (54): : 97 - 105