Experiment and performance evaluation of an integrated low-temperature proton exchange membrane fuel cell system with an absorption chiller

被引:4
|
作者
Wang, Hanbin [1 ,2 ]
Luo, Chunhuan [1 ,2 ]
Zhang, Rudan [1 ,2 ]
Li, Yongsheng [1 ,2 ]
Yang, Changchang [1 ,2 ]
Li, Zexiang [1 ,2 ]
Li, Jianhao [1 ,2 ]
Li, Na [3 ]
Li, Yiqun [4 ]
Su, Qingquan [1 ,2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Energy & Environm Engn, 30 Xueyuan Rd, Beijing 100083, Peoples R China
[2] Beijing Key Lab Energy Conservat & Emiss Reduct Me, Beijing 100083, Peoples R China
[3] State Grid Corp China, Beijing 100083, Peoples R China
[4] Anhui Polytech Univ, Sch Elect Engn, 8 Beijing Middle Rd, Wuhu 241000, Anhui, Peoples R China
关键词
Low-temperature proton exchange membrane; fuel cell; Absorption chiller; Integrated system; Waste heat recovery; Performance evaluation; HEAT-PUMP CYCLE; THERMODYNAMIC PROPERTIES; POWER-SYSTEM; ENERGY; REFRIGERATION; OPTIMIZATION; CATALYST; DESIGN; PEMFC;
D O I
10.1016/j.renene.2023.118937
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When the typical operation temperature of the Proton Exchange Membrane Fuel Cell (PEMFC) reaches 333.15-363.15 K, the ratio of electrical energy to waste heat generated by the PEMFC is about 1. In this paper, an absorption chiller with LiBr/[BMIM]Cl/CH3OH as the working pair is proposed to convert the waste heat into cooling capacity. The PEMFC and absorption chiller (AC) systems have been studied from the energy and effi-ciency point of view. The COP of the integrated system can reach a maximum of 0.85, which is remarkably 0.35 higher than that of the individual PEMFCs. The electrochemical process of the PEMFC and the thermodynamic process of the AC systems are calculated using MATLAB. The results show that the PEMFC operation temperature of 353.15-358.15K is sufficient to drive the AC and meet the requirement of 273.15-283.15K evaporation temperature and 308.15-313.15K condensation temperature. Meanwhile, when the electric power output from the PEMFC is 100 kW, the AC can output approximately 60 kW cooling capacity, which is sufficient to meet the cooling demand of the commercial bus.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Thermodynamic performance analysis of a low-temperature absorption refrigeration system in a proton exchange membrane fuel cell refrigerated vehicle
    Li, Zexiang
    Luo, Chunhuan
    Li, Jianhao
    Wang, Hanbin
    Zhang, Rudan
    Li, Na
    Pan, Chongchao
    Wang, Yanan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 154 : 378 - 385
  • [2] Performance evaluation of an integrated proton exchange membrane fuel cell system with ejector absorption refrigeration cycle
    Toghyani, S.
    Afshari, E.
    Baniasadi, E.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 185 : 666 - 677
  • [3] Performance evaluation of an integrated high-temperature proton exchange membrane fuel cell and absorption cycle system for power and heating/cooling cogeneration
    Guo, Xinru
    Zhang, Houcheng
    Zhao, Jiapei
    Wang, Fu
    Wang, Jiatang
    Miao, He
    Yuan, Jinliang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 181 : 292 - 301
  • [4] Cell performance distribution in a low-temperature proton exchange membrane fuel cell stack during propene contamination
    Jean St-Pierre
    Maheboob B. V. Virji
    Journal of Applied Electrochemistry, 2016, 46 : 169 - 181
  • [5] Comprehensive performance evaluation and advanced exergy analysis of the low-temperature proton exchange membrane fuel cell and spray flash desalination coupled system
    Cai, Benan
    Gao, Ruihang
    Zhao, Yuqi
    Wang, Rong
    Che, Xunjian
    Tian, Jiameng
    Cai, Weihua
    Energy, 2024, 313
  • [6] Cell performance distribution in a low-temperature proton exchange membrane fuel cell stack during propene contamination
    St-Pierre, Jean
    Virji, Maheboob B. V.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2016, 46 (02) : 169 - 181
  • [7] Cell performance distribution in a low-temperature proton exchange membrane fuel cell stack during propene contamination
    St-Pierre, Jean (jsp7@hawaii.edu), 1600, Springer Science and Business Media B.V. (46):
  • [8] Study on Low-temperature Startup of Proton Exchange Membrane Fuel Cell by Auxiliary Preheating
    Zhao, Hailan
    IAENG International Journal of Applied Mathematics, 2024, 54 (12) : 2702 - 2710
  • [9] Evaluation of an integrated methane autothermal reforming and high-temperature proton exchange membrane fuel cell system
    Authayanun, Suthida
    Saebea, Dang
    Patcharavorachot, Yaneeporn
    Arpornwichanop, Amornchai
    ENERGY, 2015, 80 : 331 - 339
  • [10] Thermodynamic and exergoeconomic analysis of a proton exchange membrane fuel cell/absorption chiller CCHP system based on biomass gasification
    Xie, Nan
    Xiao, Zhenyu
    Du, Wei
    Deng, Chengwei
    Liu, Zhiqiang
    Yang, Sheng
    ENERGY, 2023, 262