Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials

被引:0
|
作者
Tariq, Muhammad A. [1 ,3 ]
Ali, Uzair [1 ]
Uddin, Qazi S. [2 ]
Altaf, Zahabia [2 ]
Mohiuddin, Ashar [1 ]
机构
[1] Dow Univ Hlth Sci, Dow Univ Hosp, Dept Surg, Karachi, Pakistan
[2] Dow Univ Hlth Sci, Dow Med Coll, Dept Surg, Karachi, Pakistan
[3] Dow Univ Hosp, Dept Surg, Gulzar e Hijri Scheme 33,Suparco Rd, Karachi 74200, Pakistan
关键词
distal radius fracture; Kirschner wire; meta-analysis; volar locking plating; DORSALLY DISPLACED FRACTURE; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; FUNCTIONAL OUTCOMES; SURGICAL-TREATMENT; EXTERNAL FIXATION; OPEN REDUCTION; HAND; REHABILITATION; COMPLICATIONS;
D O I
10.1055/s-0043-1768235
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective This study aims to compare the outcomes of volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of unstable distal radius fractures. Methods We systematically searched multiple databases, including MEDLINE, EMBASE, Cochrane Central till January 2022 for randomized controlled trials (RCTs) that met eligibility criteria. Following outcomes were evaluated at 6-week, 3-, 6-, and 12-month follow-up period: Disabilities of the Arm, Shoulder, and Hand (DASH) score, Patient Rated Wrist Evaluation (PRWE) score, grip strength, range of motion, and complication incidence. Meta-analysis was performed using random effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval. Results Fourteen RCTs with 1,450 participants met the inclusion criteria. DASH scores were significantly better for VLP fixation at 6th week (MD = 19.02; p < 0.001), 3rd (MD = 10.79; p < 0.001), 6th (MD= 7.78; p < 0.001), and 12th month (MD = 2.94; p < 0.001) postoperation. At 3-month follow-up period, VLP treatment exhibited better grip strength (MD = - 10.32; p < 0.001) and PRWE scores (MD = 8.78; p < 0.001). There was a statistically significant early advantage in flexion, extension, pronation, supination, radial deviation, and ulnar deviation in the VLP group at 6-week follow-up, but at 1-year follow-up only significantly better extension was observed. At 1 year, radiographic outcomes were similar except for volar tilt favoring VLP fixation (p < 0.001). Superficial infections were more common in patients treated with K-wire (RR = 2.89; p = 0.001), but there was no difference in total complications or reoperation rates (p > 0.05). Conclusion This meta-analysis suggests that VLP fixation and K-wire fixation are both effective procedures, but existing literature does not provide sufficient evidence to demonstrate the superiority of either method. Although VLP fixation improves DASH score, extension and volar tilt at 12-month follow-up, the difference is small and unlikely to be noticeable to the patients.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 50 条
  • [21] Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
    Erhart, S.
    Toth, S.
    Kaiser, P.
    Kastenberger, T.
    Deml, C.
    Arora, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (06) : 879 - 885
  • [22] Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
    S. Erhart
    S. Toth
    P. Kaiser
    T. Kastenberger
    C. Deml
    R. Arora
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 879 - 885
  • [23] Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius
    Khan, Naveed Ullah
    Khan, Abdul Qadir
    Jameel, Muhammad
    Yaqoob, Hafiz Muhammad
    Khan, Zeeshan
    Bajwa, Mubashar Ahmad
    RAWAL MEDICAL JOURNAL, 2020, 45 (01): : 107 - 110
  • [24] Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis
    Wei, Jie
    Yang, Tu-Bao
    Luo, Wei
    Qin, Jia-Bi
    Kong, Fan-Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (02) : 265 - 275
  • [25] Efficacy and safety of volar locking plate versus cast immobilization for distal radius fractures: a systematic review and meta-analysis of randomized controlled trials
    Li, Faxiang
    Tan, Yuzhong
    Cui, Liuchao
    Tian, Lin
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2024, 59 : 108 - 116
  • [26] Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
    Shinohara, Takaaki
    Hirata, Hitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04): : 551 - 557
  • [27] Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients
    Wang, Minghui
    Wang, Bin
    Wang, Xiuhui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 1185 - 1191
  • [28] Risk Factors for Complications following Volar Locking Plate (VLP) Fixation of Unstable Distal Radius Fracture (DRF)
    Zhu, Yanbin
    Liu, Song
    Li, Yansen
    Yang, Qianru
    Miao, Ruoxiang
    Zhang, Yingze
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [29] Comparison of internal and external fixation of distal radius fractures A meta-analysis of randomized controlled trials
    Xie, Xuetao
    Xie, Xiaoxing
    Qin, Hui
    Shen, Longxiang
    Zhang, Changqing
    ACTA ORTHOPAEDICA, 2013, 84 (03) : 286 - 291
  • [30] A Comparative Study of Displaced Distal Radius Fracture Treated With K Wire Vs Volar Locking Plate Fixation
    Manzoor, Imran
    Sarwar, Muhammad Usman
    Saleem, Muhammad
    Ali, Muhammad
    Rabbani, Shaukat
    Ishtiaq, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 323 - 326