Development and validation of a clinical tool to semi-automatic measure three-dimensional TAR alignment on two-dimensional radiographs

被引:1
|
作者
van Hoogstraten, Sanne W. G. [1 ,2 ]
Hermus, Joris [1 ]
Verbiest, Vera [2 ]
van Rietbergen, Bert [1 ,2 ]
Arts, Jacobus J. C. [1 ,2 ]
机构
[1] Maastricht Univ Med Ctr, Dept Orthoped Surg, Lab Expt Orthoped, Maastricht, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn Orthoped Biomech, Eindhoven, Netherlands
关键词
Total Ankle Replacement; Malalignment; Radiographic measurements; Subsidence; Migration; TOTAL ANKLE REPLACEMENT; RADIOSTEREOMETRIC ANALYSIS; FOLLOW-UP; DEFORMITY; ARTHROPLASTIES; PROSTHESIS; MIGRATION; REGISTER; TERM;
D O I
10.1186/s13047-023-00640-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Malalignment is often postulated as an important reason for the high failure rate of total ankle replacements (TARs). The correlation between TAR malalignment and clinical outcome, however, is not fully understood. Improving and expanding radiographic TAR alignment measurements in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurements on radiographs in the clinic. Methods A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed in MATLAB. Using the principle of edge contouring and the perpendicular relationship between the anteroposterior and lateral radiographs, the exact configuration of the TAR components can be found. Two observers validated the tool by measuring TAR alignment of ten patients using the tool. The Intraclass Coefficient (ICC) was calculated to assess the reliability of the developed method. The results obtained by the tool were compared to clinical results during radiographic follow-up in the past, and the accuracy of both methods was calculated using three-dimensional CT data. Results The tool showed an accuracy of 76% compared to 71% for the method used during follow-up. ICC values were 0.94 (p < 0.01) and higher for both inter-and intra-observer reliability. Conclusions The tool presents a reproducible method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to most TAR designs, it offers a valuable addition in the clinic and for research purposes.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Advances in two-dimensional and three-dimensional computer vision
    Sutton, MA
    McNeill, SR
    Helm, JD
    Chao, YJ
    [J]. PHOTO-MECHANICS, 2000, 77 : 323 - 372
  • [32] A comparison between the two-dimensional and three-dimensional lattices
    Dolocan, A
    Dolocan, VO
    Dolocan, V
    [J]. MODERN PHYSICS LETTERS B, 2004, 18 (25): : 1301 - 1309
  • [33] Three-dimensional diffraction tomography by two-dimensional sectioning
    Halse, OR
    Stammes, JJ
    Devaney, AJ
    [J]. OPTICS COMMUNICATIONS, 2003, 224 (4-6) : 185 - 195
  • [34] Two-Dimensional and Three-Dimensional Evaluation of the Deformation Relief
    Alfyorova, E. A.
    Lychagin, D. V.
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS WITH HIERARCHICAL STRUCTURE FOR NEW TECHNOLOGIES AND RELIABLE STRUCTURES 2017 (AMHS'17), 2017, 1909
  • [35] Synthetic opal as two-dimensional and three-dimensional nanotemplates
    White, PA
    Heales, L
    Barber, RL
    Pham, KN
    Turney, TW
    [J]. AUSTRALIAN JOURNAL OF CHEMISTRY, 2001, 54 (9-10) : 629 - 631
  • [36] Three-dimensional object recognition in the absence of two-dimensional
    Phinney, RE
    Noguiera, CAM
    Siegel, RM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 848 - 848
  • [37] Two-dimensional versus three-dimensional cell counting
    Selemon, LD
    Rajkowska, G
    [J]. BIOLOGICAL PSYCHIATRY, 2002, 51 (10) : 838 - 840
  • [38] From two-dimensional to three-dimensional quantum dots
    Lindemann, S
    Ihn, T
    Heinzel, T
    Ensslin, K
    Maranowski, K
    Gossard, AC
    [J]. PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2002, 13 (2-4): : 638 - 641
  • [39] Two-dimensional and three-dimensional sonography of conjoined twins
    Bonilla-Musoles, F
    Machado, LE
    Osborne, NG
    Blanes, J
    Bonilla, F
    Raga, F
    Machado, F
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (02) : 68 - 75
  • [40] Two-Dimensional and Three-Dimensional Ultrasound of Artificial Skin
    Wortsman, Ximena
    Navarrete, Nelson
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (01) : 225 - 230