Orientation of capture antibodies on gold nanoparticles to improve the sensitivity of ELISA-based medical devices

被引:0
|
作者
Susini, Vanessa [1 ]
Ferraro, Giovanni [2 ,3 ]
Fierabracci, Vanna [1 ]
Ursino, Silvia [1 ]
Sanguinetti, Chiara [1 ]
Caponi, Laura [1 ]
Romiti, Nadia [1 ]
Rossi, Veronica Lucia [4 ]
Sanesi, Antonio [4 ]
Paolicchi, Aldo [1 ]
Franzini, Maria [1 ]
Fratini, Emiliano [2 ,3 ]
机构
[1] Univ Pisa, Dept Translat Res & New Surg & Med Technol, Via Savi 10, I-56126 Pisa, Italy
[2] Univ Florence, Dept Chem Ugo Schiff, Via Lastruccia 3, I-50019 Florence, Italy
[3] Univ Florence, Ctr Colloid & Surface Sci CSGI, Via Lastruccia 3, I-50019 Florence, Italy
[4] BioMerieux Italia Spa, Via Campigliano 58, I-50012 Florence, Italy
关键词
Gold nanoparticles; Controlled plastic decoration; Oriented capture antibodies; Medical device; Analytical sensitivity; PROSTATE-SPECIFIC ANTIGEN; DIAGNOSIS; FEMALE; ASSAY;
D O I
10.1016/j.talanta.2023.124650
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity of ELISA-based devices strongly depends on the right orientation of antibodies on the sensor surface. The aim of this work was to increase the analytical performance of a commercial ELISA-based medical device (VIDAS (R)), thanks to the specific orientation of antibodies on gold nanostructured disposables. For this purpose, fPSA VIDAS (R) assay was used as model and the disposable providing the antigen binding surface (SPR (R)) was functionalized with gold nanostructures coated with monovalent half-fragment antibodies (reduced IgG, rIgG). The functionalization of polystyrene SPRs (R) with gold nanostructures was achieved through a one-step incubation of gold dispersions in a mixture of non-toxic solvents. Five different concentrations of gold nanoparticles (NPs) were tested with a maximum fluorescence enhancement for NPs density around 3-8 *103 NPs/ mu m2 (752 +/- 11 RFV vs 316 +/- 5 RFV of bare SPRs (R)). The comparison of the dose-response curve obtained with commercial and gold coated-SPRs (R) revealed a significant improvement (p < 0.0001) of the analytical sensitivity of the VIDAS (R) system using nanostructured disposables. This improved version of SPRs (R) allows to distinguish small variations of fPSA concentrations opening the way to the application of this biomarker to other kinds of cancer as recently described in the literature.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Medical bio sensing of collagen gold nanoparticles conjugated to improve the dermis and joints
    Draghiciu, L.
    Ignat, T.
    Romanitan, C.
    Gavrila, R.
    Mihalache, I
    Parvulescu, C.
    CAS 2020 PROCEEDINGS: 2020 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 2020, : 187 - 190
  • [22] An ELISA-based procedure for assaying proteins in digests of human leukocytes and cell lines, using specifically selected peptides and appropriate antibodies
    Ori Braitbard
    Janette Bishara-Shieban
    Hava Glickstein
    Miriam Kott-Gutkowski
    Umberto Pace
    Deborah G Rund
    Wilfred D Stein
    Proteome Science, 4
  • [23] Evaluation of ELISA-Based Multiplex Peptides for the Detection of Human Serum Antibodies Induced by Zika Virus Infection across Various Countries
    Viedma, Maria del Pilar Martinez
    Panossian, Stephen
    Gifford, Kennedy
    Garcia, Kimberly
    Figueroa, Isis
    Parham, Leda
    de Moraes, Laise
    Gomes, Lillian Nunes
    Garcia-Salum, Tamara
    Perret, Cecilia
    Weiskopf, Daniela
    Tan, Gene S.
    Silva, Antonio Augusto
    Boaventura, Viviane
    Ruiz-Palacios, Guillermo M.
    Sette, Alessandro
    De Silva, Aruna Dharshan
    Medina, Rafael A.
    Lorenzana, Ivette
    Akrami, Kevan M.
    Khouri, Ricardo
    Olson, Daniel
    Pickett, Brett E.
    VIRUSES-BASEL, 2021, 13 (07):
  • [24] Establishment of an indirect ELISA-based method involving the use of a multiepitope recombinant S protein to detect antibodies against canine coronavirus
    Yun-Feng Hao
    Shao-Han Li
    Guang-Zhi Zhang
    Yi Xu
    Guang-zong Long
    Xiao-xiong Lu
    Shang-Jin Cui
    Tong Qin
    Archives of Virology, 2021, 166 : 1877 - 1883
  • [25] An ELISA-based procedure for assaying proteins in digests of human leukocytes and cell lines, using specifically selected peptides and appropriate antibodies
    Braitbard, Ori
    Bishara-Shieban, Janette
    Glickstein, Hava
    Kott-Gutkowski, Miriam
    Pace, Umberto
    Rund, Deborah G.
    Stein, Wilfred D.
    PROTEOME SCIENCE, 2006, 4 (1)
  • [26] Determination of anti-endomysium XgA antibodies in the diagnosis of celiac disease: Comparison of a novel ELISA-based assay with conventional immunofluorescence
    Poland, Dennis C. W.
    Ceelie, Huib
    Dinkelaar, Rob B.
    Beijer, Cornelis
    WORLD JOURNAL OF GASTROENTEROLOGY, 2006, 12 (17) : 2779 - 2780
  • [27] False-positive results in ELISA-based anti FVIII antibody assay may occur with lupus anticoagulant and phospholipid antibodies
    Sahud, M.
    Zhukov, O.
    Mo, K.
    Popov, J.
    Dlott, J.
    HAEMOPHILIA, 2012, 18 (05) : 777 - 781
  • [28] Determination of anti-endomysium IgA antibodies in the diagnosis of celiac disease:Comparison of a novel ELISA-based assay with conventional immunofluorescence
    Dennis CW Poland
    Huib Ceelie
    Rob B Dinkelaar
    Cornelis Beijer
    World Journal of Gastroenterology, 2006, (17) : 2779 - 2780
  • [29] Evaluation of commercially available fully automated and ELISA-based assays for detecting anti-SARS-CoV-2 neutralizing antibodies
    Zedan, Hadeel T.
    Yassine, Hadi M.
    Al-Sadeq, Duaa W.
    Liu, Na
    Qotba, Hamda
    Nicolai, Eleonora
    Pieri, Massimo
    Bernardini, Sergio
    Abu-Raddad, Laith J.
    Nasrallah, Gheyath K.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Establishment of an indirect ELISA-based method involving the use of a multiepitope recombinant S protein to detect antibodies against canine coronavirus
    Hao, Yun-Feng
    Li, Shao-Han
    Zhang, Guang-Zhi
    Xu, Yi
    Long, Guang-zong
    Lu, Xiao-xiong
    Cui, Shang-Jin
    Qin, Tong
    ARCHIVES OF VIROLOGY, 2021, 166 (07) : 1877 - 1883