A Spherical Coil Array for the Calibration of Whole-Head Magnetoencephalograph Systems

被引:4
|
作者
Adachi, Yoshiaki [1 ]
Oyama, Daisuke [1 ]
Higuchi, Masanori [1 ]
Uehara, Gen [1 ]
机构
[1] Kanazawa Inst Technol, Appl Elect Lab, Nonoichi, Ishikawa 9218811, Japan
关键词
Sensor arrays; Calibration; Sensors; Magnetic sensors; Magnetic fields; Sensor systems; SQUIDs; magnetoencephalography; magnetometers; superconducting quantum interference devices (SQUIDs); uncertainty estimation;
D O I
10.1109/TIM.2023.3265750
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We proposed a spherical coil array for determining the positions, orientations, and sensitivities of the magnetometers for whole-head magnetoencephalograph (MEG) systems. The coil array comprises 16 concentric and symmetrically oriented circular coils with a diameter of 150 mm, which is larger than those of conventional calibration coil arrays, such as 5 or 60 mm. The accuracy of the calibration was expected to improve because the relative mechanical errors in machining and assembly could be reduced when the coil diameter was increased. Moreover, we also proposed a method to estimate the uncertainties in calibration, and it was demonstrated that the sensor parameters of each sensor were successfully obtained with uncertainties using a spherical calibration coil array. Additionally, the accuracy of the calibration was evaluated using a dry-type MEG phantom, and as expected, it was found that the accuracy was improved from that of a conventional calibration coil array composed of an assembly of multiple three-axis bobbins.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Nonlinear synchronization in EEG and whole-head MEG recordings of healthy subjects
    Stam, CJ
    Breakspear, M
    van Walsum, AMV
    van Dijk, BW
    HUMAN BRAIN MAPPING, 2003, 19 (02) : 63 - 78
  • [22] Measurement of brain function in pre-school children using a custom sized whole-head MEG sensor array
    Johnson, Blake W.
    Crain, Stephen
    Thornton, Rosalind
    Tesan, Graciela
    Reid, Melanie
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (03) : 340 - 349
  • [23] Dynamical properties of whole-head EEG synchronization: Spontaneous and evoked activity
    van Leeuwen, Cees
    NEUROSCIENCE RESEARCH, 2007, 58 : S31 - S31
  • [24] Analysis and design of whole-head magnetic brain stimulators: A simulation study
    School of Electrical Engineering and Computer Science, Seoul National University, San 56-1, Sillim-dong, Kwanak-gu, Seoul 151-744, Korea, Republic of
    不详
    Int. J. Control Autom. Syst., 2007, 3 (337-342):
  • [25] Whole-head recording of chemosensory activity in the marine annelid Platynereis dumerilii
    Chartier, Thomas F.
    Deschamps, Joran
    Duerichen, Wiebke
    Jekely, Gaspar
    Arendt, Detlev
    OPEN BIOLOGY, 2018, 8 (10)
  • [26] Vector-type magnetometers improve the localization of equivalent current dipoles below the edge of a whole-head MEG sensor array
    Adachi Y.
    Transactions of Japanese Society for Medical and Biological Engineering, 2021, Annual 59 (Proc): : 726 - 728
  • [27] Transformation of whole-head MEG recordings between different sensor positions
    Knösche, TR
    BIOMEDIZINISCHE TECHNIK, 2002, 47 (03): : 59 - 62
  • [28] Cortical activity reduction with stimulus repetition: a whole-head MEG analysis
    Penney, TB
    Maess, B
    Busch, N
    Derrfuss, J
    Mecklinger, A
    COGNITIVE BRAIN RESEARCH, 2003, 16 (02): : 226 - 231
  • [29] Analysis and design of whole-head magnetic brain stimulators: A simulation study
    Lee, Chany
    Im, Chang-Hwan
    Jung, Hyun-Kyo
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2007, 5 (03) : 337 - 342
  • [30] Global brain metabolic quantification with whole-head proton MRS at 3 T
    Kirov, Ivan I.
    Wu, William E.
    Soher, Brian J.
    Davitz, Matthew S.
    Huang, Jeffrey H.
    Babb, James S.
    Lazar, Mariana
    Fatterpekar, Girish
    Gonen, Oded
    NMR IN BIOMEDICINE, 2017, 30 (10)