Study of Heat Recovery Equipment for Building Applications

被引:0
|
作者
Popescu, Lelia Letitia [1 ]
Popescu, Razvan Stefan [1 ]
Catalina, Tiberiu [1 ,2 ]
机构
[1] Tech Univ Civil Engn Bucharest, Bldg Serv Fac, Bucharest 020396, Romania
[2] Natl Res & Dev Inst URBAN INCERC, Bucharest 021652, Romania
关键词
heat transfer; plate heat exchanger; tank in tank" method; finite volumes; dynamical simulation; Matlab/Simulink; EXCHANGER; SIMULATION; MODEL;
D O I
10.3390/buildings13123125
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, heat exchangers find widespread use across various applications in different fields, particularly in the field of heat recovery. This paper provides a detailed explanation of a plate heat exchanger counter-flow model developed in Simulink/Matlab. Water was employed in simulations for both circuits, although the thermal properties of other fluids can be investigated by modifying them. The "Tanks in series" method was used for simulation purposes. The developed model enables users to explore the impact of various parameters on heat exchanger functionality, such as altering the number of plates, the material or thickness of the plates, and the nature of thermal agents (gaseous or liquid). These models play a crucial role not only in simulating and sizing heat exchangers but also in achieving parametric optimization. Parameter variations can be employed to examine the operation of existing equipment under conditions different from their design specifications. The Simulink/Matlab proposed model, featuring a variable number of finite volumes to ensure high accuracy, was compared to the classical design method for plate heat exchangers. The results revealed good accuracy, with relative errors for heat transfer rate remaining below 2.6%. This research also considered the study of the number of finite volumes necessary for achieving accurate results. For the 40 finite volumes model, the relative error for heat transfer rate is less than 10%. Dividing the mesh into 50 finite volumes along the fluid flow direction resulted in relative errors ranging from 1.6% to 1.7%, indicating that a finer mesh was not necessary. To validate the conceived model, experimental data from the literature were compared. The relative errors for heat transfer rate between the Matlab/Simulink model's results and experimental data ranged from 1.58% to 11.92%, demonstrating a strong agreement between the conceived model and the experimental values.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Heat transfer study of external convective and radiative coefficients for building applications
    Evangelisti, L.
    Guattari, C.
    Gori, P.
    Bianchi, F.
    ENERGY AND BUILDINGS, 2017, 151 : 429 - 438
  • [22] HEAT RECOVERY-SYSTEM FOR A NEWSPAPER BUILDING
    不详
    REFRIGERATION AND AIR CONDITIONING, 1974, 77 (912): : 24 - &
  • [23] A review of the applications of heat pipe heat exchangers for heat recovery
    Srimuang, W.
    Amatachaya, P.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (06): : 4303 - 4315
  • [24] Analysis of heat gain decrease achieved by ventilation heat recovery in solar cooling building: case study
    Gil, Bartosz
    Rosiek, Sabina
    Kasperski, Jacek
    Nems, Magdalena
    Nems, Artur
    Batlles, Francisco J.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 2521 - 2528
  • [25] Advanced Heat Exchangers for Waste Heat Recovery Applications
    Jouhara, Hussam
    CHEMENGINEERING, 2023, 7 (01)
  • [26] WASTE HEAT RECOVERY FOR OFFSHORE APPLICATIONS
    Pierobon, Leonardo
    Kandepu, Rambabu
    Haglind, Fredrik
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 503 - 512
  • [27] Waste heat recovery technologies and applications
    Jouhara, Hussam
    Khordehgah, Navid
    Almahmoud, Sulaiman
    Delpech, Bertrand
    Chauhan, Amisha
    Tassou, Savvas A.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 6 : 268 - 289
  • [28] Numerical investigation of the performance of a PCM-based renewable and exhaust heat recovery system for building applications
    Shahsavar, Amin
    ENERGY, 2024, 286
  • [29] SELECTION OF WASTE HEAT RECOVERY EQUIPMENT IN PETROLEUM REFINING.
    Miller, Roy W.
    1978,
  • [30] BASIC CONSIDERATIONS IN SELECTING WASTE-HEAT-RECOVERY EQUIPMENT
    HOLZHAUER, R
    PLANT ENGINEERING, 1978, 32 (17) : 108 - 114