Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer?

被引:0
|
作者
Frohlich, Georgina [1 ,2 ]
Vizkeleti, Julia [1 ]
Nguyen, Anhhong Nhung [1 ]
Polgar, Csaba [1 ,3 ]
Takacsi-Nagy, Zoltan [1 ,3 ]
Major, Tibor [1 ,3 ]
机构
[1] Natl Inst Oncol, Ctr Radiotherapy, Budapest, Hungary
[2] Eotvos Lorand Univ, Dept Biophys, Fac Nat Sci, Budapest, Hungary
[3] Semmelweis Univ, Dept Oncol, Fac Med, Budapest, Hungary
关键词
cervical cancer; ring activation; ring applicator; Venezia applicator; interstitial brachytherapy; GUIDED ADAPTIVE BRACHYTHERAPY; SOCIETY CONSENSUS GUIDELINES; LOCALLY ADVANCED-CARCINOMA; RADIATION-THERAPY; AMERICAN BRACHYTHERAPY; MRI; RADIOTHERAPY; POINT; RECOMMENDATIONS; FEASIBILITY;
D O I
10.5114/jcb.2023.124399
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients. Material and methods: Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints. EQD2 total doses from external beam and BT of target volumes and organs at risk (OARs) between the competing plans were compared. Results: There was no significant difference in the dose of high-risk clinical target volume (HR-CTV) and gross tumor volume (GTV) between the plans with inactive vs. active R/O. The mean D98 of intermediate-risk clinical target volume (IR-CTV) was significantly lower with inactive R/O; however, the GEC-ESTRO (EMBRACE II study) and ABS criteria were fulfilled in 96% in both plans. There was no difference in dose homogeneity, but conformity of the plans with inactive R/O was higher. Doses to all OARs were significantly lower in plans without R/O activation. While all the plans without R/O activation fulfilled the recommended dose criteria for OARs, it was less achievable with R/O activation. Conclusions: Inactivation of R/O applicator results in similar dose coverage of the target volumes with lower doses to all OARs, as activation of R/O in cervix cancer patients when HR-CTV does not extend to R/O applicator. The use of active source positions in R/O shows worse performance regarding the fulfilment of the recommended criteria for OARs.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 50 条
  • [31] Interstitial round needles should not be used for cervical cancer patient treated with intracavitary/ interstitial brachytherapy using a Venezia applicator : a case report
    Takagawa, Yoshiaki
    Izumi, Sachiko
    Takahashi, Eiichi
    Kita, Midori
    BMC WOMENS HEALTH, 2024, 24 (01)
  • [32] Combined intracavitary and interstitial brachytherapy of cervical cancer using the novel hybrid applicator Venezia: Clinical feasibility and initial results
    Walter, Franziska
    Maihoefer, Cornelius
    Schuettrumpf, Lars
    Well, Justus
    Burges, Alexander
    Ertl-Wagner, Birgit
    Mahner, Sven
    Belka, Claus
    Gallwas, Julia
    Corradini, Stefanie
    BRACHYTHERAPY, 2018, 17 (05) : 775 - 781
  • [33] Applicator-guided SBRT boost combined with intracavitary brachytherapy for advanced cervical cancer
    Constantinescu, C.
    Jastaniyah, N.
    Ramahi, S. Wadi
    Nobah, A.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S156 - S158
  • [34] Analysis of clinical utilization of ring applicator for combined intracavitary/interstitial image-guided brachytherapy treatment in Chinese patients with locally advanced cervical cancer
    Zhao, Zhipeng
    Zhang, Ning
    Liu, Ying
    Wu, Ning
    Mao, Zhuang
    Yang, Wei
    Chong, Guanghui
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (03) : 252 - 259
  • [35] Split-Ring Applicator with Interstitial Needle for Improved Volumetric Coverage in HDR Brachytherapy for Cervical Cancer
    Sherertz, T.
    Ellis, R.
    Colussi, V.
    Mislmani, M.
    Traughber, B.
    Herrmann, K.
    Podder, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 390 - 391
  • [36] Expected benefit of a combined intracavitary and interstitial tandem ovoid applicator for 3D MR based brachytherapy of cervical cancer
    Van der Wal, E.
    de Leeuw, A.
    Jurgenliemk-Schulz, I.
    Moerland, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S35 - S35
  • [37] Image-guided intracavitary and interstitial brachytherapy in locally advanced cervical cancer
    Chitmanee, P.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1929 - S1930
  • [38] Inverse planning for combination of intracavitary and interstitial brachytherapy for locally advanced cervical cancer
    Yoshio, Kotaro
    Murakami, Naoya
    Morota, Madoka
    Harada, Ken
    Kitaguchi, Mayuka
    Yamagishi, Kentaro
    Sekii, Shuhei
    Takahashi, Kana
    Inaba, Koji
    Mayahara, Hiroshi
    Ito, Yoshinori
    Sumi, Minako
    Kanazawa, Susumu
    Itami, Jun
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (06) : 1146 - 1152
  • [39] Combined Interstitial and Intracavitary High-Dose Rate Brachytherapy of Cervical Cancer
    Itami, Jun
    Murakami, Naoya
    Watanabe, Miho
    Sekii, Shuhei
    Kasamatsu, Takahiro
    Kato, Shingo
    Hirowatari, Hisako
    Ikushima, Hitoshi
    Ando, Ken
    Ohno, Tatsuya
    Okamoto, Hiroyuki
    Okuma, Kae
    Igaki, Hiroshi
    FRONTIERS IN ONCOLOGY, 2022, 11
  • [40] PLANNING ASPECTS OF COMBINED INTRACAVITARY/INTERSTITIAL (IC/IS) BRACHYTHERAPY FOR PATIENTS WITH CERVICAL CANCER
    Nomden, C.
    Jurgenliemk-Schulz, I. M.
    Moerland, M.
    de Leeuw, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S89 - S90