Enhancement in the limit of detection of lab-on-chip microfluidic devices using functional nanomaterials

被引:14
|
作者
Vaishampayan, Vijay [1 ]
Kapoor, Ashish [2 ]
Gumfekar, Sarang P. [1 ,3 ]
机构
[1] Indian Inst Technol Ropar, Dept Chem Engn, Rupnagar, India
[2] Harcourt Butler Tech Univ, Dept Chem Engn, Kanpur, India
[3] Indian Inst Technol Ropar, Dept Chem Engn, Rupnagar 140001, Punjab, India
来源
CANADIAN JOURNAL OF CHEMICAL ENGINEERING | 2023年 / 101卷 / 09期
关键词
lab-on-chip; limit of detection; microfluidics; nanomaterials; sensing; PAPER-BASED MICROFLUIDICS; GOLD NANOPARTICLES; POINT; ASSAY; FABRICATION; TIME; ELECTRONICS; DIAGNOSTICS; SEPARATION; DISEASES;
D O I
10.1002/cjce.24915
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Technological developments in recent years have witnessed a paradigm shift towards lab-on-chip devices for various diagnostic applications. Lab-on-chip technology integrates several functions typically performed in a large-scale analytical laboratory on a small-scale platform. These devices are more than the miniaturized versions of conventional analytical and diagnostic techniques. The advances in fabrication techniques, material sciences, surface modification strategies, and their integration with microfluidics and chemical and biological-based detection mechanisms have enormously enhanced the capabilities of these devices. The minuscule sample and reagent requirements, capillary-driven pump-free flows, faster transport phenomena, and ease of integration with various signal readout mechanisms make these platforms apt for use in resource-limited settings, especially in developing and underdeveloped parts of the world. The microfluidic lab-on-a-chip technology offers a promising approach to developing cost-effective and sustainable point-of-care testing applications. Numerous merits of this technology have attracted the attention of researchers to develop low-cost and rapid diagnostic platforms in human healthcare, veterinary medicine, food quality testing, and environmental monitoring. However, one of the major challenges associated with these devices is their limited sensitivity or the limit of detection. The use of functional nanomaterials in lab-on-chip microfluidic devices can improve the limit of detection by enhancing the signal-to-noise ratio, increasing the capture efficiency, and providing capabilities for devising novel detection schemes. This review presents an overview of state-of-the-art techniques for integrating functional nanomaterials with microfluidic devices and discusses the potential applications of these devices in various fields.
引用
收藏
页码:5208 / 5221
页数:14
相关论文
共 50 条
  • [31] Organic optoelectronics for lab-on-chip fluorescence detection
    Jahns, Sabrina
    Balke, Jan
    Iwers, Andre F. K.
    Gerken, Martina
    TM-TECHNISCHES MESSEN, 2017, 84 : S48 - S51
  • [32] Lab-on-chip detection of biomolecules with integrated sensors
    Conde, J.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2013, 42 : S108 - S108
  • [33] Is a real-time quantifiable liquid biopsy achievable using a microfluidic lab-on-chip ?
    Casali, Veronica
    Guithon, Ingrid Clerc
    Sanden, Boudewijn van der
    Stephan, Olivier
    Gredy, Laetitia
    Vilgrain, Isabelle
    Martin, Donald K.
    EUROBIOTECH JOURNAL, 2023, 7 (04): : 189 - 195
  • [34] On-Line Testing of Lab-on-Chip Using Reconfigurable Digital-Microfluidic Compactors
    Zhao, Yang
    Chakrabarty, Krishnendu
    INTERNATIONAL JOURNAL OF PARALLEL PROGRAMMING, 2009, 37 (04) : 370 - 388
  • [35] On-Line Testing of Lab-on-Chip Using Reconfigurable Digital-Microfluidic Compactors
    Yang Zhao
    Krishnendu Chakrabarty
    International Journal of Parallel Programming, 2009, 37 : 370 - 388
  • [36] Rapid prototyping Lab-on-Chip devices for the future: A numerical optimisation of bulk optical parameters in microfluidic systems
    Lu, Sarah E.
    Morris, Andrew
    Clinton-Bailey, Geraldine
    Namiq, Medya
    Gow, Paul C.
    Birchill, Antony
    Steigenberger, Sebastian
    Wyatt, James
    Forrester, Reuben
    Mowlem, Matthew C.
    Warwick, Phillip E.
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 359
  • [37] Integratable Capacitive Sensor for Identification of Microfluidic Two-Phase Flow Patterns in Lab-on-Chip Devices
    Yang, Zhaochu
    Dong, Tao
    Jensen, Atle
    Halvorsen, Einar
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2016, 25 (01) : 197 - 206
  • [38] A New Lab-on-Chip Transmitter for the Detection of Proteins Using RNA Aptamers
    Tasdemir, Ferhat
    Zihir, Samet
    Ozeren, Emre
    Niazi, Javed H.
    Qureshi, Anjum
    Kallempudi, S. Saravan
    Kaynak, Mehmet
    Scholz, Rene
    Gurbuz, Yasar
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 489 - 492
  • [39] High-voltage contactless conductivity-detection for lab-on-chip devices using external electrodes on the holder
    Tanyanyiwa, J
    Abad-Villar, EM
    Fernández-Abedul, MT
    Costa-García, A
    Hoffmann, W
    Guber, AE
    Herrmann, D
    Gerlach, A
    Gottschlich, N
    Hauser, PC
    ANALYST, 2003, 128 (08) : 1019 - 1022
  • [40] Microfluidic chip system model (Lab-on-chip) in research on quality of mammalian oocytes and embryos
    Kempisty, Bartosz
    Walczak, Rafal
    Sniadek, Patrycja
    Pootrowska, Hanna
    Wozna, Magdalena
    Jackowska, Marta
    Bukowska, Dorota
    Antosik, Pawel
    Dzouban, Jan
    Jaskowski, Jedrzej M.
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2011, 67 (08): : 522 - 526