Role of Near-Infrared Spectroscopy in Monitoring the Clinical Course of Asphyxiated Neonates Treated with Hypothermia

被引:5
|
作者
Farag, Marwa Mohamed [1 ]
Khedr, Ahmed Abd El-Halim Abd El-Raziq [1 ]
Attia, MennattAllah Hassan [2 ]
Ghazal, Hesham Abd EL-Rahim [1 ]
机构
[1] Alexandria Univ Hosp, Pediat Dept, Alexandria, Egypt
[2] Alexandria Univ, Fac Med, Dept Forens Med & Clin Toxicol, Alexandria, Egypt
关键词
hypoxic-ischemia; therapeutic hypothermia; clinical seizures; near-infrared spectroscopy; cRSO (2); FTOE; AMPLITUDE-INTEGRATED ELECTROENCEPHALOGRAPHY; HYPOXIC-ISCHEMIC ENCEPHALOPATHY; CEREBRAL OXYGENATION; BRAIN PERFUSION; NEWBORNS; SEIZURES; BURDEN; MRI;
D O I
10.1055/s-0041-1740513
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Hypoxic-ischemic encephalopathy (HIE) affects millions of newborns annually, especially in low-resource settings. Real-time monitoring of hypoxic-ischemic brain damage is urgently needed for assessment of severity and management of neonates with birth asphyxia. Aim of the work is monitoring of near-infrared spectroscopy (NIRS)-measured cerebral regional oxygen saturation (cRSO (2)) and cerebral fractional tissue oxygen extraction (FTOE) in neonates after birth asphyxia in relation to their clinical course. Study Design Forty asphyxiated-term and near-term neonates with mild to severe HIE admitted at neonatal intensive care unit of Alexandria University Maternity Hospital from March to October 2019, received therapeutic hypothermia (TH) and had continuous NIRS monitoring of cRSO (2) for 72 hours. Infants were categorized into HIE with seizing and nonseizing groups, and abnormal and normal magnetic resonance imaging (MRI) groups. Results Clinical seizures (CS) occurred in 15 (37.5%) of HIE neonates and 13.3% of them died ( n = 2). In the current study, significantly higher cRSO (2) and lower FTOE values were found in the seizing infants as compared with nonseizing group ( p < 0.001). NIRS-measured day 2-cRSO (2) and day 1-FTOE were associated with CS in newborns with HIE and day 1-cRSO (2) and FTOE were associated with abnormal MRI at 1 month of age. cRSO (2) values were found to correlate positively with initial Thompson score especially in days 1 and 2. Further, neonates with CS were more likely to have MRI abnormalities at follow-up. Conclusion NIRS measures may highlight differences between asphyxiated neonates who develop CS or later MRI abnormalities and those who do not.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [21] Clinical near-infrared spectroscopy and imaging
    Ferrari, Marco
    Culver, Joseph P.
    Hoshi, Yoko
    Wabnitz, Heidrun
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (09)
  • [22] Near-infrared spectroscopy - Clinical applications
    Simonson, SG
    Piantadosi, CA
    CRITICAL CARE CLINICS, 1996, 12 (04) : 1019 - &
  • [23] Near-infrared spectroscopy for bioprocess monitoring and control
    Yeung, KSY
    Hoare, M
    Thornhill, NF
    Williams, T
    Vaghjiani, JD
    BIOTECHNOLOGY AND BIOENGINEERING, 1999, 63 (06) : 684 - 693
  • [24] Monitoring blood loss with near-infrared spectroscopy
    Torella, F
    Cowley, R
    McCollum, CN
    Thorniley, MS
    BRITISH JOURNAL OF SURGERY, 2001, 88 (05) : 753 - 753
  • [25] Implanted near-infrared spectroscopy for cardiac monitoring
    Bhunia, Sourav K.
    Cinbis, Can
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [26] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    Dunn, Jeffrey F.
    Zhang, Qiong
    Wu, Ying
    Srinivasan, Sathyanarayanan
    Smith, Michael R.
    Shaw, R. Anthony
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [27] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    University of Calgary, Experimental Imaging Centre, Faculty of Medicine, 3330 Hospital Drive NW, Calgary, AB T2N 4N1, Canada
    不详
    不详
    不详
    不详
    J Biomed Opt, 2008, 6
  • [28] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243
  • [29] Near-infrared spectroscopy for monitoring muscle oxygenation
    Boushel, R
    Piantadosi, CA
    ACTA PHYSIOLOGICA SCANDINAVICA, 2000, 168 (04): : 615 - 622
  • [30] Usefulness of near-infrared spectroscopy in thrombectomy monitoring
    Thomas Ritzenthaler
    Tae-Hee Cho
    David Luis
    Yves Berthezene
    Norbert Nighoghossian
    Journal of Clinical Monitoring and Computing, 2015, 29 : 585 - 589