Risk factors associated with early implant failure: A retrospective review

被引:10
|
作者
Yari, Amir [1 ]
Fasih, Paniz [2 ]
Alborzi, Shahram [3 ]
Nikzad, Hooman [4 ]
Romoozi, Elahe [5 ,6 ]
机构
[1] Kashan Univ Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, 56th Hekmat St, Kashan, Iran
[2] Kashan Univ Med Sci, Sch Dent, Dept Prosthodont, Kashan, Iran
[3] Shiraz Univ Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Shiraz, Iran
[4] Univ Exeter, Fac Environm Sci & Econ, Sub Dept Operat & Analyt, Dept Management, Exeter, England
[5] Univ Tehran Med Sci, Dent Res Inst, Dent Res Ctr, Tehran, Iran
[6] Univ Tehran Med Sci, Sch Dent, Dept Penodontol, Tehran, Iran
关键词
Dental implant; Osseointegration; Survival rate; Risk factor; Risk assessment; DENTAL IMPLANTS; SYSTEMIC FACTORS; IMPACT;
D O I
10.1016/j.jormas.2023.101749
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to investigate the association between possible risk factors and early implant failure. Patients and methods: This retrospective cohort study included consecutive patients receiving dental implant treatment in a four-year timeframe. Patient-related variables (age, sex, smoking, and systemic disease), local factors (area, reason for tooth extraction, and bone quality), surgical variables (bone augmentation, time of implant placement, staging, and antibiotic prophylaxis), and implant-related factors (brand, length, and diameter) were analyzed. Bivariate analyses and multivariate logistic regression model were used to determine the variables associated with early implant failure. Results: The study group comprised 1323 implants in 738 patients with a mean of 1.8 implants/patient of which, 53 failed in 52 patients in the early stage (before final prosthetic loading). According to the multivariate model, smoking (Odds Ratio=1.836, P=0.031), posterior maxillary region (OR=2.958, P=0.006), implantation in place of teeth extracted due to periodontal problems (OR=2.531, P=0.004), bone type IV (OR=2.881, P=0.008), implant in previously augmented site (OR=2.239, P=0.014), and immediate provisional prosthesis (OR=3.418, P=0.019) were associated with a significantly higher risk of early implant failure. Narrow implants showed a significantly higher risk of early failure in bivariate analyses (P=0.012). However, the effect was no longer significant in the multivariate model (OR=2.322, P=0.068). Conclusion: Early implant failure would be more expected in smokers, posterior maxilla, history of periodontal problems, type IV bone, augmented bone, and immediately loaded cases. (c) 2023 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Risk factors for Baerveldt implant failure
    Fechter, HP
    Chang, RT
    Feuer, W
    Budenz, DL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U375 - U375
  • [22] What Factors Are Associated With Implant Failure?
    Block, Michael S.
    Christensen, Brian J.
    Mercante, Don E.
    Chapple, Andrew G.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (01) : 91 - 97
  • [23] Risk factors in dental implant failure
    Wang, IC
    Reddy, MS
    Geurs, NC
    Jeffcoat, MK
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1996, 6 (02) : 103 - 117
  • [24] Evaluation of the Association of Early Implant Failure With Local, Environmental, and Systemic Factors: A Retrospective Study
    Costa Coelho, Tayane da Rocha
    de Azevedo, Roberto Almeida
    Borges Maia, Wolf Wanderley
    dos Santos, Jean Nunes
    Cury, Patricia Ramos
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (06) : 1237 - 1245
  • [25] Risk factors for implant failure: a retrospective study in an educational institution using GEE analyses
    Borba, Marcelo
    Deluiz, Daniel
    Veras Lourenco, Eduardo Jose
    Oliveira, Luciano
    Tannure, Patricia Nivoloni
    BRAZILIAN ORAL RESEARCH, 2017, 31 : 1 - 7
  • [26] Early Implant Failure Associated With Patient Factors, Surgical Manipulations, and Systemic Conditions
    Carr, Alan B.
    Arwani, Noura
    Lohse, Christine M.
    Gonzalez, Ricardo L. Vidal
    Muller, Olivia M.
    Salinas, Thomas J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (06): : 623 - 633
  • [27] Correlates of Early Dental Implant Failure: A Retrospective Study
    Basson, Ayelet Aviva
    Mann, Jonathan
    Findler, Mordechai
    Chodick, Gabriel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (05) : 897 - 906
  • [28] Is Penicillin Allergy a Risk Factor for Early Dental Implant Failure? A Systematic Review
    Salgado-Peralvo, Angel-Orion
    Pena-Cardelles, Juan-Francisco
    Kewalramani, Naresh
    Ortiz-Garcia, Ivan
    Jimenez-Guerra, Alvaro
    Uribarri, Andrea
    Velasco-Ortega, Eugenio
    Moreno-Munoz, Jesus
    Nunez-Marquez, Enrique
    Monsalve-Guil, Loreto
    ANTIBIOTICS-BASEL, 2021, 10 (10):
  • [29] PARASTOMAL HERNIA INCIDENCE AND ASSOCIATED RISK FACTORS: A RETROSPECTIVE REVIEW
    Dorman, Christine
    Collins, Elizabeth Cole
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2020, 47 : S1 - S1
  • [30] A retrospective review of the prognosis and risk factors associated with endogenous endophthalmitis
    Lee, SH
    Dovich, J
    Fan, J
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S133 - S134