The effect of crowding on the accuracy of 3-dimensional printing

被引:3
|
作者
Spangler, Tonya [1 ]
Ammoun, Rami [2 ]
Carrico, Caroline K. [3 ]
Bencharit, Sompop [4 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, 520 N 12th St,POB 980566, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Sch Dent, Dept Dent Publ Hlth & Policy, Richmond, VA 23298 USA
[4] Med Univ South Carolina, James B Coll Dent Med, Dept Oral Rehabil, Off Oral Hlth Innovat, Charleston, SC USA
关键词
FIT;
D O I
10.1016/j.ajodo.2023.08.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the accuracy of 3-dimensional (3D) printed aligners compared to conventional vacuum-formed thermoplastic aligners with varying levels of dental crowding. Methods: Digital intraoral scans of 10 cases were assigned to their respective groups (n = 10, each, 30 total) as follows: no crowding (control), moderate crowding, and severe crowding. Digital images of these models were created in standard tessellation language (STL) file format using 3Shape software and randomly 3D printed. The STL files of each case were also sent to a dental laboratory to fabricate vacuum-formed samples, the current technology used for manufacturing aligners. The intaglio surfaces of fabricated aligners in both groups were scanned using cone beam computed tomography to create STL files, which were then compared to the original STL files of the cases using Geomagic Control X software. Absolute deviations from the original file and root mean square values were recorded. A Kruskal-Wallis test was conducted to analyze the difference in average deviation, and a t-test was repeated for the RMS measure. The significance level was set at 0.05. Results: The crowding did not affect the trueness of aligners manufactured using 3D printing or conventional vacuum-forming techniques (P = 0.79). 3D-printed aligners showed less deviation than the vacuum-formed samples (0.1125 mm vs 0.1312 mm; P \0.01). Aligners manufactured with the vacuum-forming technique had significantly higher variation than those with the 3D printing process (P = 0.04). Conclusions: 3D aligners printed directly from an STL file exhibited better precision and trueness than those fabricated using the conventional vacuum-forming technique. Since accuracy is defined as a combination of precision and trueness, it is concluded that direct printing from an STL file can be used to manufacture aligners. (Am J Orthod Dentofacial Orthop 2023;164:879-88)
引用
收藏
页码:879 / 888
页数:10
相关论文
共 50 条
  • [41] Accuracy and Reproducibility of a 3-Dimensional Stereophotogrammetric Imaging System
    de Menezes, Marcio
    Rosati, Riccardo
    Ferrario, Virgilio F.
    Sforza, Cbiarella
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (09) : 2129 - 2135
  • [42] THE ACCURACY OF DLT EXTRAPOLATION IN 3-DIMENSIONAL FILM ANALYSIS
    WOOD, GA
    MARSHALL, RN
    JOURNAL OF BIOMECHANICS, 1986, 19 (09) : 781 - &
  • [43] Intrinsic accuracy in 3-dimensional photoemission band mapping
    Strocov, VN
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2003, 130 (1-3) : 65 - 78
  • [44] Accuracy Assessment of 3-Dimensional LiDAR Building Extraction
    Saraf, Noraain Mohamed
    Hamid, Juazer Rizal Abdul
    Halim, Maisarah Abdul
    Rasam, Abdul Rauf Abdul
    Lin, Saharuddin
    2018 IEEE 14TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING & ITS APPLICATIONS (CSPA 2018), 2018, : 261 - 266
  • [45] Accuracy and reproducibility of 3-dimensional digital model measurements
    Sousa, Marines Vieira S.
    Vasconcelos, Eliziane Cossetin
    Janson, Guilherme
    Garib, Daniela
    Pinzan, Arnaldo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (02) : 269 - 273
  • [46] MEASURING ACCURACY OF 3-DIMENSIONAL DISPLACEMENTS IN HOLOGRAPHIC INTERFEROMETRY
    MATSUMOT.T
    IWATA, K
    NAGATA, R
    APPLIED OPTICS, 1973, 12 (05): : 961 - 967
  • [47] 3-DIMENSIONAL MEASUREMENT ACCURACY OF SKULL SURFACE LANDMARKS
    HILDEBOLT, CF
    VANNIER, MW
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1988, 76 (04) : 497 - 503
  • [48] EFFECT OF RADIOGRAPHIC LANDMARK IDENTIFICATION ERRORS ON THE ACCURACY OF 3-DIMENSIONAL RECONSTRUCTION OF THE HUMAN SPINE
    ANDRE, B
    DANSEREAU, J
    LABELLE, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) : 569 - 575
  • [49] Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models
    Ko, Jennifer
    Bloomstein, Richard D.
    Briss, David
    Holland, J. Nathaniel
    Morsy, Hamdy Mohammed
    Kasper, F. Kurtis
    Huang, Wei
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 160 (03) : 451 - +
  • [50] EFFECT OF CHARACTERISTICS OF CAMERAS ON ACCURACY OF REPRODUCTION OF A 3-DIMENSIONAL PICTURE OF EVENTS RECORDED BY THEM
    IVANOV, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (06): : 1352 - &