Performance improvement of solar air heater duct-employing rib roughness on absorber: an experimental study

被引:2
|
作者
Kant, Ravi [1 ]
Alam, Tabish [2 ,3 ]
Singh, Dheerandra [1 ]
Sabeeh, Ahmed [1 ]
机构
[1] MMM Univ Technol, Dept Mech Engn, Gorakhpur, India
[2] Cent Bldg Res Inst, CSIR, Architecture Planning & Energy Efficiency, Roorkee, India
[3] Cent Bldg Res Inst, CSIR, Architecture Planning & Energy Efficiency, Roorkee 247667, India
关键词
Solar air heater; heat transfer enhancement; thermohydraulic performance; hybrid-shaped ribs; FRICTION FACTOR CORRELATIONS; TRANSFER ENHANCEMENT; THERMOHYDRAULIC PERFORMANCE; TRANSFER AUGMENTATION; RECTANGULAR DUCT; TURBULATORS; FLOW;
D O I
10.1080/08916152.2023.2268080
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar energy is a pure and plentiful source of power for daily activities. Out of many solar thermal system, Solar air heaters (SAHs) are frequently regarded as the most economical and practical method of heating and drying indoor spaces. Due to its poor performance and minimal heat transfer capacity, its applicability in certain circumstances is quite limited. In this paper, an effort has been made to improve the heat transfer efficiency of SAH by utilizing hybrid ribs. Hybrid rib roughnesses are designed to integrate V-shaped ribs downstream of arc-shaped ribs and were experimentally tested in the SAH duct at Reynolds numbers (RN) between 2000 and 16,000. The various roughness pattern i.e. arc angle (alpha), relative V ribs position (d/w), relative rib pitch (p/e) and relative rib height (e/Dh) have been exploited in the range of 30o-75o, 0.2-0.8, 8-14 and 0.036-0.056, respectively. As a result, maximum enhancement in NuNu has been found as 3.75 at alpha = 45o, d/w = 0.5, p/e = 12, e/D = 0.056. Thermohydraulic Performance (TP) parameters have also been evaluated for all set of parameters and it was found to be maximum 2.49 at alpha = 45o, d/w = 0.5, p/e = 12, and e/Dh = 0.036.
引用
收藏
页码:1139 / 1154
页数:16
相关论文
共 50 条
  • [41] Exergy based analysis of solar air heater having discrete V-down rib roughness on absorber plate
    Singh, Sukhmeet
    Chander, Subhash
    Saini, J. S.
    ENERGY, 2012, 37 (01) : 749 - 758
  • [42] Nusselt number and friction factor correlation of solar air heater having twisted-rib roughness on absorber plate
    Kumar, Anup
    Layek, Apurba
    RENEWABLE ENERGY, 2019, 130 : 687 - 699
  • [43] An Experimental Study of Thermohydraulic Performance of Solar Air Heater Having Multiple Open Trapezoidal Rib Roughnesses
    Karmveer
    Gupta, Naveen Kumar
    Alam, Tabish
    Singh, Himanshu
    EXPERIMENTAL HEAT TRANSFER, 2024, 37 (03) : 313 - 333
  • [44] Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater
    Chaube, A
    Sahoo, PK
    Solanki, SC
    RENEWABLE ENERGY, 2006, 31 (03) : 317 - 331
  • [45] Experimental study on the performance of spiral solar air heater
    Jia, Binguang
    Liu, Fang
    Wang, Da
    SOLAR ENERGY, 2019, 182 : 16 - 21
  • [46] Performance improvement of a solar air heater by covering the absorber plate with a thin porous material
    Jouybari, Nima Fallah
    Lundstrom, T. Staffan
    ENERGY, 2020, 190
  • [47] Performance improvement of a solar air heater by covering the absorber plate with a thin porous material
    Jouybari, Nima Fallah
    Lundström, T. Staffan
    Energy, 2020, 190
  • [48] Experimental and CFD-based thermal performance prediction of solar air heater provided with chamfered square rib as artificial roughness
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Chamoli, Sunil
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (02) : 643 - 663
  • [49] Experimental and CFD-based thermal performance prediction of solar air heater provided with chamfered square rib as artificial roughness
    Vipin B. Gawande
    A. S. Dhoble
    D. B. Zodpe
    Sunil Chamoli
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 643 - 663
  • [50] Review of development of artificial roughness in solar air heater and performance evaluation of different orientations for double arc rib roughness
    Lanjewar, A. M.
    Bhagoria, J. L.
    Agrawal, M. K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 : 1214 - 1223