Ultra-high-resolution optical coherence tomography for the investigation of thin multilayered pharmaceutical coatings

被引:5
|
作者
Wolfgang, Matthias [1 ]
Kern, Alice [2 ]
Deng, Shiyu [2 ]
Stranzinger, Sandra [1 ]
Liu, Mengyang [2 ,4 ,5 ]
Drexler, Wolfgang [2 ]
Leitgeb, Rainer [2 ,6 ]
Haindl, Richard [2 ,3 ,4 ,5 ]
机构
[1] Res Ctr Pharmaceut Engn GmbH, Graz, Austria
[2] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[3] Nanyang Technol Univ, Sch Chem Chem Engn & Biotechnol, 62 Nanyang Dr, Singapore, Singapore
[4] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Chem Engn, Singapore
[5] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Biotechnol, Singapore
[6] Med Univ Vienna, Christian Doppler Lab OPTRAMED, Vienna, Austria
基金
欧盟地平线“2020”;
关键词
Optical Coherence Tomography (OCT); Multiparticulate dosage forms; Multi-layer coatings; Automated image segmentation; Coating layer thickness variability; DRUG-RELEASE; OCT; MICROSCOPY; POLYMERS; PELLETS; BLENDS;
D O I
10.1016/j.ijpharm.2023.123096
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Optical Coherence Tomography (OCT) has recently gained attention as a promising technology for in-line monitoring of pharmaceutical film-coating processes for (single-layered) tablet coatings and end-point detec-tion with commercial systems. An increasing interest in the investigation of multiparticulate dosage forms with mostly multi-layered coatings below 20 & mu;m final film thickness demands advancement in OCT technology for pharmaceutical imaging. We present an ultra-high-resolution (UHR-) OCT and investigate its performance based on three different multiparticulate dosage forms with different layer structures (one single-layered, two multi-layered) with layer thicknesses in a range from 5 to 50 & mu;m. The achieved system resolution of 2.4 & mu;m (axial) and 3.4 & mu;m (lateral, both in air) enables the assessment of defects, film thickness variability and morphological features within the coating, previously unattainable using OCT. Despite the high transverse resolution, the provided depth of field was found sufficient to reach the core region of all dosage forms under test. We further demonstrate an automated segmentation and evaluation of UHR-OCT images for coating thicknesses, where human experts struggle using today's standard OCT systems.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Accuracy and Repeatability of Ultra-High Resolution Optical Coherence Tomography
    Hutchings, N.
    Hyun, C.
    Mishra, A.
    Bizheva, K.
    Simpson, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [22] En-face scanning optical coherence tomography with ultra-high resolution for material investigation
    Wiesauer, K
    Pircher, M
    Götzinger, E
    Bauer, S
    Engelke, R
    Ahrens, G
    Grützner, G
    Hitzenberger, CK
    Stifter, D
    OPTICS EXPRESS, 2005, 13 (03): : 1015 - 1024
  • [23] High Resolution Optical Coherence Tomography
    Ge, Xin
    Chen, Shufen
    Chen, Si
    Liu, Linbo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 3824 - 3835
  • [24] Ultra-high resolution optical coherence tomography for encapsulation quality inspection
    Czajkowski, J.
    Fabritius, T.
    Ulanski, J.
    Marszalek, T.
    Gazicki-Lipman, M.
    Nosal, A.
    Sliz, R.
    Alarousu, E.
    Prykari, T.
    Myllyla, R.
    Jabbour, G.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 105 (03): : 649 - 657
  • [25] Ultra-high resolution optical coherence tomography for encapsulation quality inspection
    J. Czajkowski
    T. Fabritius
    J. Ulański
    T. Marszałek
    M. Gazicki-Lipman
    A. Nosal
    R. Śliż
    E. Alarousu
    T. Prykäri
    R. Myllylä
    G. Jabbour
    Applied Physics B, 2011, 105 : 649 - 657
  • [26] Ultra-High Resolution Optical Coherence Tomography of the Ageing Lamina Cribrosa
    North, R. V.
    Mortlock, K. E.
    Hermann, B.
    Tumlinson, A. R.
    Povazay, B.
    Morgan, J. E.
    Drexler, W.
    Albon, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [27] Ultra-high-resolution Fluorescence Images in Thin Phosphor Films
    Riesen, N.
    Badek, K.
    Ruan, Y.
    Monro, T. M.
    Riesen, H.
    AOS AUSTRALIAN CONFERENCE ON OPTICAL FIBRE TECHNOLOGY (ACOFT) AND AUSTRALIAN CONFERENCE ON OPTICS, LASERS, AND SPECTROSCOPY (ACOLS) 2019, 2019, 11200
  • [28] Ultra-High-Resolution 3D Optical Coherence Tomography Reveals Inner Structures of Human Placenta-Derived Trophoblast Organoids
    Deloria, Abigail J.
    Haider, Sandra
    Dietrich, Bianca
    Kunihs, Victoria
    Oberhofer, Simon
    Knofler, Martin
    Leitgeb, Rainer
    Liu, Mengyang
    Drexler, Wolfgang
    Haindl, Richard
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (08) : 2368 - 2376
  • [29] THEORY OF ULTRA-HIGH-RESOLUTION OPTICAL RAMAN RAMSEY SPECTROSCOPY
    DALTON, BJ
    KIEU, TD
    KNIGHT, PL
    OPTICA ACTA, 1986, 33 (04): : 459 - 472
  • [30] Ultra-High-Resolution OTDR based on Linear Optical Sampling
    Wang, Shuai
    Fan, Xinyu
    Wang, Bin
    Yang, Guangyao
    Liu, Qingwen
    He, Zuyuan
    2016 21ST OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) HELD JOINTLY WITH 2016 INTERNATIONAL CONFERENCE ON PHOTONICS IN SWITCHING (PS), 2016,