Research on the performance of a valveless piezoelectric pump with a herringbone bluffbody

被引:3
|
作者
Yu, Dahai [1 ]
Hu, Renhui [2 ]
Huang, Yongxin [2 ]
Hu, Dianbin [2 ]
He, Lipeng [2 ]
Cheng, Guangming [3 ]
机构
[1] Changchun Guanghua Univ, Sch Elect & Informat, Changchun 130033, Jilin, Peoples R China
[2] Changchun Univ Technol, Sch Mechatron Engn, Changchun 130012, Jilin, Peoples R China
[3] Zhejiang Normal Univ, Inst Precis Machinery, Jinhua 321004, Zhejiang, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 04期
关键词
Back flow - Bluff body - Flow-resistance coefficients - Intrinsic frequency - Output flow - Output performance - Performance - Piezoelectric pump - Pump chambers - Valve-less pumps;
D O I
10.1063/5.0128739
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aiming to improve the output performance of a valveless piezoelectric pump, this article presents a valveless piezoelectric pump with a herringbone bluffbody. The bluffbody is herringbone shaped and distributed in a tapered chamber. The tapered chamber and the bluffbody create a large reverse resistance in the chamber, thus effectively mitigating the backflow problem of the valveless pump. The theoretical analysis determined the relationship between the flow rate and the flow resistance coefficient as well as the variation of the pump chamber volume. It was also concluded that the piezoelectric pump has the best output flow at intrinsic frequencies. Through simulation calculations, the effectiveness of the bluffbody structure in mitigating backflow in piezoelectric pumps is analyzed to provide a reference for experimental prototype design parameters. Finally, a range of prototypes is produced for experimentation. The experimental results show that the designed bluffbody shape can increase the return energy loss to effectively mitigate the return flow issues of the valveless piezoelectric pump, thus improving the output performance. The optimum output flow rate is 158.5 ml/min at 200 V and 52.5 Hz and the tapered chamber angle of 6 degrees, and the bluffbody height, angle, and quantities are 2 mm, 40 degrees, and 2, respectively. The construction of the valveless piezoelectric pump proposed in this research can be used as a reference for subsequent improvements in the performance of valveless piezoelectric pumps, and due to the high output performance, experimental studies can be carried out in applications such as dispensing and heat dissipation in electronic products.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Design of a Valveless Type Piezoelectric Pump for Micro-Fluid Devices
    Kim, Hyun-Hoo
    Oh, Jin-Heon
    Yoon, Jae-Hun
    Jeong, Eui-Hwan
    Lim, Kee-Joe
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2010, 11 (02) : 65 - 68
  • [42] Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes
    ZHANG JianHui1
    2 College of Mechanical & Electronic Engineering
    3 Shanghai Aircraft Design and Research Institute
    4 College of Astronautics
    5 State Key Lab of Digital Manufacturing Equipment & Technology
    6 State Key Laboratory of Mechanics and Control for Mechanical Structures
    Science China Technological Sciences, 2011, (11) : 3070 - 3077
  • [43] Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes
    Zhang JianHui
    Xia QiXiao
    Huang Yi
    Leng XueFei
    Huang Jun
    Zhao ChunSheng
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (11) : 3070 - 3077
  • [44] Experimental study of valveless piezoelectric pump with raindrop-shaped tubes
    Li Fan
    Zhang Jianhu
    Tang Ming
    Chen Chaobin
    Bao Qibo
    PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON SERVICE ROBOTICS TECHNOLOGIES (ICSRT 2018), 2018, : 42 - 45
  • [45] Design and Experimental Study of Valveless Piezoelectric Pump with Asymmetrical Bifurcated Channels
    Tian P.
    Huang J.
    Shi W.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2020, 40 (06): : 1178 - 1183
  • [46] A spiral-tube-type valveless piezoelectric pump with gyroscopic effect
    Jianhui Zhang
    Xuefei Leng
    Chunsheng Zhao
    Science Bulletin, 2014, (16) : 1885 - 1889
  • [47] Recent trends in structures and applications of valveless piezoelectric pump-a review
    Hou, Yi
    He, Lipeng
    Hu, Dianbin
    Zhang, Limin
    Yu, Baojun
    Cheng, Guangming
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2022, 32 (05)
  • [48] Simulation and Experiment on the Fish-tailing Type of valveless piezoelectric pump
    Huang, Yi
    Zhang, Jianhui
    Hu, Xiaoqi
    Xia, Qixiao
    Huang, Weiqing
    Zhao, Chunsheng
    ICMS2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION, VOL 2: MODELLING AND SIMULATION IN ENGINEERING, 2010, : 380 - 383
  • [49] Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes
    JianHui Zhang
    QiXiao Xia
    Yi Huang
    XueFei Leng
    Jun Huang
    ChunSheng Zhao
    Science China Technological Sciences, 2011, 54 : 3070 - 3077
  • [50] Design and Analysis of a Cardioid Flow Tube Valveless Piezoelectric Pump for Medical Applications
    Wang, Jialong
    Zhang, Fan
    Gui, Zhenzhen
    Wen, Yuxin
    Zeng, Yaohua
    Xie, Tang
    Tan, Tian
    Chen, Bochuan
    Zhang, Jianhui
    SENSORS, 2024, 24 (01)