ITER Toroidal Interferometer and Polarimeter (TIP) beam refraction in 3D density profiles

被引:5
|
作者
Van Zeeland, M. A. [1 ]
Akiyama, T. [1 ]
Becoulet, M. [2 ]
Kim, C. [3 ]
机构
[1] Gen Atom, POB 85608, San Diego, CA 92186 USA
[2] CEA, IRFM, F-13108 St Paul Les Durance, France
[3] SLS2 Consulting, San Diego, CA 92186 USA
关键词
Interferometry; Refraction; Plasma diagnostics; ITER; Ray tracing; density measurement;
D O I
10.1016/j.fusengdes.2023.113618
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Calculations of the expected refraction of the five ITER Toroidal Interferometer and Polarimeter (TIP) chords are presented for a range of conditions including high-density axisymmetric, ELMing H-mode cases and shattered pellet disruption mitigation cases. The calculations are carried out with a newly developed ray tracing code capable of following TIP's 10.59 mu m laser beams through arbitrary 3D electron density profiles. Using JOREK simulations of ELM density perturbations in a 15MA ITER baseline plasma, it is shown that refraction from ELMs is expected to be negligible. It is found, however, that TIP interferometers will be able to clearly resolve the line-integrated density perturbation from ELMs and contribute to the ITER measurement requirement "14. H-mode, ELMs and L-H mode transition indicator". Calculations of the expected refraction in a NIMROD simulated shattered pellet disruption mitigation scenario with peak local electron densities of n(e) = 3.7 x 10(21) m(-3) (max line-averaged densities of n(avg) = 1.3 x 10(21) m(-3)) also show tolerable refraction and it is likely that most, if not all chords, would avoid signal loss. For both axisymmetric and structured plasmas with line-averaged densities in the mid to upper 10(21) m(-3) range, values likely present only during disruption mitigation, refraction becomes significant and could limit the ability of TIP to make reliable density measurements.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] 3D Refraction-Corrected Transmission Reconstruction for 3D Ultrasound Computer Tomography
    Dapp, Robin
    Gemmeke, Hartmut
    Ruiter, Nicole
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [42] Toroidal states in 28Si with covariant density functional theory in 3D lattice space
    Ren, Z. X.
    Zhao, P. W.
    Zhang, S. Q.
    Meng, J.
    NUCLEAR PHYSICS A, 2020, 996
  • [43] Optimizing 3D refraction and reflection survey design
    Zhang, J
    Lavely, E
    PROCEEDINGS OF THE SYMPOSIUM ON THE APPLICATION OF GEOPHYSICS TO ENVIRONMENTAL AND ENGINEERING PROBLEMS, 1998, : 101 - 106
  • [44] Refraction Correction in 3D Transcranial Ultrasound Imaging
    Lindsey, Brooks D.
    Smith, Stephen W.
    ULTRASONIC IMAGING, 2014, 36 (01) : 35 - 54
  • [45] Fully 3D refraction correction dosimetry system
    Manjappa, Rakesh
    Makki, S. Sharath
    Kumar, Rajesh
    Vasu, Ram Mohan
    Kanhirodan, Rajan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1722 - 1737
  • [46] 3D reconstruction of a micro pipette tip
    Ostadi, H.
    Malboubi, M.
    Prewett, P. D.
    Jiang, K.
    MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) : 868 - 870
  • [47] INVESTIGATION OF TOROIDAL AND POLOIDAL ASYMMETRIES OF THE EDGE DENSITY PROFILES IN THE CASTOR TOKAMAK USING A THERMAL LITHIUM BEAM
    WEIXELBAUM, L
    HAYESS, E
    WENZEL, U
    BADALEC, J
    JAKUBKA, K
    KRYSKA, L
    STOECKEL, J
    VALOVIC, M
    ZACEK, F
    JOURNAL OF NUCLEAR MATERIALS, 1990, 176 : 904 - 908
  • [48] 3D PROFILES - PRINCIPLES AND APPLICATIONS
    BOWLE, JU
    LUTHY, R
    WILMANNS, M
    WESSON, L
    KAM, Z
    EISENBERG, D
    PROTEIN ENGINEERING, 1993, 6 : 123 - 123
  • [49] Emulation of Spatially Distributed Plasma Density Profiles in 3D Electromagnetic Field Simulations
    Hattenhorst, Birk
    Pohle, Dennis
    Schulz, Christian
    Rolfes, Ilona
    Musch, Thomas
    2019 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON ADVANCED MATERIALS AND PROCESSES FOR RF AND THZ APPLICATIONS (IMWS-AMP 2019), 2019, : 166 - 168
  • [50] An optimized interferometer for 3D digital holographic endoscopy
    Osten, W
    Kolenovic, E
    Klattenhoff, R
    Köpp, N
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION III, 2003, 5144 : 150 - 161