Non-Newtonian turbulent flow through aortic phantom: Experimental and computational study using magnetic resonance imaging and lattice Boltzmann method

被引:3
|
作者
Eichler, Pavel [1 ,4 ]
Galabov, Radek [1 ,2 ]
Fucik, Radek [1 ]
Skardova, Katerina [1 ]
Oberhuber, Tomas [1 ]
Paus, Petr [1 ]
Tintera, Jaroslav [2 ]
Chabiniok, Radomir [1 ,3 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Trojanova 13, Prague 12000, Czech Republic
[2] Inst Clin & Expt Med, Prague, Czech Republic
[3] UT Southwestern Med Ctr, Dept Pediat, Div Pediat Cardiol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[4] FJFI CVUT Praze, Katedra Matematiky, Trojanova 13, Prague 2, Czech Republic
关键词
Non-Newtonian flow; Phase-contrast magnetic resonance imaging; Lattice Boltzmann method; Turbulent fluid flow; Carreau-Yasuda model; BLOOD-FLOW; FLUID; MODEL;
D O I
10.1016/j.camwa.2023.01.031
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
The necessity of using non-Newtonian models for hemodynamics in geometries mimicking large vessels is investigated. Phase-contrast magnetic resonance imaging (PC-MRI) measurements are performed on a specially-designed phantom representing the aorta while using several types of fluids. These measurements are compared against the results of the lattice Boltzmann method (LBM) computational fluid dynamics (CFD) simulator in 3D. On the phantom side, two types of non-Newtonian fluids (water-based solutions of glycerine with xanthan gum and sucrose with xanthan gum) and Newtonian fluid (clear water) are used in the experiments; three different acrylic plates are inserted to represent aortic stenosis of varying degrees; and two constant flow regimes with high and low flow rates are used. The CFD simulations in the geometry and inflow boundary conditions corresponding to each experiment are performed both with non-Newtonian and Newtonian approaches. Additionally, the accuracy of the PC-MRI flow measurements is assessed and discussed with respect to the known PC-MRI flow underestimation due to turbulence. Based on the type of stenosis and inflow rate, the results indicate that the Newtonian models produce comparable results with the experimentally acquired data, which is in favor of overall less expensive Newtonian models.
引用
收藏
页码:80 / 94
页数:15
相关论文
共 50 条
  • [11] Flow of Newtonian and Non-Newtonian Fluids Through Packed Beds: An Experimental Study
    Kaur, Navdeep
    Singh, Raveena
    Wanchoo, R. K.
    TRANSPORT IN POROUS MEDIA, 2011, 90 (02) : 655 - 671
  • [12] Lattice Boltzmann investigation of non-Newtonian fluid flow through a packed bed of uniform spheres
    Qi, Zheng
    Kuang, Shibo
    Yu, Aibing
    POWDER TECHNOLOGY, 2019, 343 : 225 - 236
  • [13] Flow of Newtonian and Non-Newtonian Fluids Through Packed Beds: An Experimental Study
    Navdeep Kaur
    Raveena Singh
    R. K. Wanchoo
    Transport in Porous Media, 2011, 90 : 655 - 671
  • [14] A multi-domain lattice Boltzmann mesh refinement method for non-Newtonian blood flow modeling
    Daeian, Mohammad Ali
    Smith, W. Spencer
    Keshavarz-Motamed, Zahra
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [15] Comparison of Newtonian and non-Newtonian flows in a two-dimensional carotid artery model using the lattice Boltzmann method
    Boyd, J.
    Buick, J. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20): : 6215 - 6228
  • [16] Lattice Boltzmann Study of Non-Newtonian Blood Flow in Mother and Daughter Aneurysm and a Novel Stent Treatment
    Shi, Y.
    Tang, G. H.
    Tao, W. Q.
    ADVANCES IN APPLIED MATHEMATICS AND MECHANICS, 2014, 6 (02) : 165 - 178
  • [17] Non-Newtonian rheology property for two-phase flow on fingering phenomenon in porous media using the lattice Boltzmann method
    Shi, Y.
    Tang, G. H.
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2016, 229 : 86 - 95
  • [18] Direct numerical simulation of turbulent non-Newtonian flow using a spectral element method
    Rudman, M.
    Blackburn, H. M.
    APPLIED MATHEMATICAL MODELLING, 2006, 30 (11) : 1229 - 1248
  • [19] Study of Non-Newtonian Blood Flow Through Arteries Using Openfoam
    Suresh, Arjun
    Rajan, Vikas
    INTERNATIONAL CONFERENCE ON APPLIED MECHANICS AND OPTIMISATION (ICAMEO-2019), 2019, 2134
  • [20] Computational Modeling of Non-Newtonian Blood Flow Through Stenosed Arteries in the Presence of Magnetic Field
    Alshare, Aiman
    Tashtoush, Bourhan
    El-Khalil, Hossam H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (11):