Changes of aortic hemodynamics after aortic valve replacement-A four dimensional flow cardiovascular magnetic resonance follow up study

被引:3
|
作者
Wiesemann, Stephanie [1 ,2 ,3 ,4 ,5 ,6 ]
Trauzeddel, Ralf Felix [1 ,2 ,3 ,4 ,6 ,7 ,8 ]
Musa, Ahmed [1 ,2 ,3 ,4 ]
Hickstein, Richard [1 ,2 ,3 ,4 ]
Mayr, Thomas [1 ,2 ,3 ,4 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ,3 ,4 ,9 ]
Bollache, Emilie [10 ]
Markl, Michael [11 ]
Schulz-Menger, Jeanette [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Charite Univ Med Berlin, Berlin, Germany
[2] Free Univ Berlin, Berlin, Germany
[3] Humboldt Univ, Berlin, Germany
[4] Working Grp Cardiovasc Magnet Resonance, ECRC Expt & Clin Res Ctr, Berlin, Germany
[5] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[7] Charite Univ Med Berlin, Berlin, Germany
[8] Charite Campus Benjamin Franklin, Dept Anesthesiol & Intens Care Med, Berlin, Germany
[9] Ludwig Maximilian Univ Munich, Dept Cardiol, Clin Agatharied, Hausham, Germany
[10] Sorbonne Univ, Lab Imagerie Biomed LIB, CNRS, INSERM, Paris, France
[11] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL USA
来源
关键词
cardiovascular magnetic resonance imaging; 4D flow; aorta; aortic stenosis; bicuspid aortic valve; aortic valve replacement; WALL SHEAR-STRESS; ASCENDING AORTA; DILATION; MRI;
D O I
10.3389/fcvm.2023.1071643
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesNon-invasive assessment of aortic hemodynamics using four dimensional (4D) flow magnetic resonance imaging (MRI) provides new information on blood flow patterns and wall shear stress (WSS). Aortic valve stenosis (AS) and/or bicuspid aortic valves (BAV) are associated with altered aortic flow patterns and elevated WSS. Aim of this study was to investigate changes in aortic hemodynamics over time in patients with AS and/or BAV with or without aortic valve replacement. MethodsWe rescheduled 20 patients for a second 4D flow MRI examination, whose first examination was at least 3 years prior. A total of 7 patients received an aortic valve replacement between baseline and follow up examination (=operated group = OP group). Aortic flow patterns (helicity/vorticity) were assessed using a semi-quantitative grading approach from 0 to 3, flow volumes were evaluated in 9 planes, WSS in 18 and peak velocity in 3 areas. ResultsWhile most patients had vortical and/or helical flow formations within the aorta, there was no significant change over time. Ascending aortic forward flow volumes were significantly lower in the OP group than in the NOP group at baseline (NOP 69.3 mL +/- 14.2 mL vs. OP 55.3 mL +/- 1.9 mL p = 0.029). WSS in the outer ascending aorta was significantly higher in the OP group than in the NOP group at baseline (NOP 0.6 +/- 0.2 N/m(2) vs. OP 0.8 +/- 0.2 N/m(2), p = 0.008). Peak velocity decreased from baseline to follow up in the aortic arch only in the OP group (1.6 +/- 0.6 m/s vs. 1.2 +/- 0.3 m/s, p = 0.018). ConclusionAortic valve replacement influences aortic hemodynamics. The parameters improve after surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Four-dimensional flow cardiovascular magnetic resonance aortic cross-sectional pressure changes and their associations with flow patterns in health and ascending thoracic aortic aneurysm
    Bouaoua, Kevin
    Dietenbecka, Thomas
    Soulatb, Gilles
    Bargiotasc, Ioannis
    Houriez-Gombaud-Saintongea, Sophia
    De Cesarea, Alain
    Gencerb, Umit
    Girona, Alain
    Jimeneza, Elena
    Messasb, Emmanuel
    Lucore, Didier
    Bollachea, Emilie
    Mousseauxb, Elie
    Kachenouraa, Nadjia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [32] Mid-term follow-up of aortic valve replacement for bicuspid aortic valve
    Liu, Lingchao
    Li, Tianbo
    Xu, Bo
    Liu, Chencheng
    Tang, Fuqin
    Xiao, Yingbin
    Wang, Yong
    CARDIOLOGY IN THE YOUNG, 2021, 31 (08) : 1290 - 1296
  • [33] Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment
    Bissell, Malenka M.
    Loudon, Margaret
    Hess, Aaron T.
    Stoll, Victoria
    Orchard, Elizabeth
    Neubauer, Stefan
    Myerson, Saul G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [34] Prevalence of permanent pacemaker implantation after conventional aortic valve replacement-a propensity-matched analysis in patients with a bicuspid or tricuspid aortic valve: a benchmark for transcatheter aortic valve replacement
    Haunschild, Josephina
    Misfeld, Martin
    Schroeter, Thomas
    Lindemann, Frank
    Davierwala, Piroze
    von Aspern, Konstantin
    Spampinato, Ricardo A.
    Weiss, Stefan
    Borger, Michael A.
    Etz, Christian D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (01) : 130 - 137
  • [35] Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment
    Malenka M. Bissell
    Margaret Loudon
    Aaron T. Hess
    Victoria Stoll
    Elizabeth Orchard
    Stefan Neubauer
    Saul G. Myerson
    Journal of Cardiovascular Magnetic Resonance, 20
  • [36] Evaluation of Aortic Hemodynamics Using Four-Dimensional Flow of Magnetic Resonance Imaging in Rabbits with Liver Fibrosis
    Li, Jiali
    Li, Yuansheng
    Lin, Xin
    Lv, Cheng
    Zhang, Xiaoyong
    Chen, Jing
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (06) : 2604 - 2612
  • [37] Embolic Cerebral Insults and Microbleeds after Percutaneous Aortic Valve Replacement and Surgical Aortic Valve Replacement detected by Magnetic Resonance Imaging
    Ensminger, Stephan
    Ott, Sabine
    Achenbach, Stephan
    Heim, Christian
    Feyrer, Richard
    Loders, Sabrina
    Doerfler, Arndt
    Daniel, Werner
    Weyand, Michael
    Ludwig, Josef
    Arnold, Martin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B255 - B255
  • [38] CHANGES OF MITRAL REGURGITATION AFTER SURGICAL AORTIC VALVE REPLACEMENT AND TRANSCATHETER AORTIC VALVE IMPLANTATION: A TWO-DIMENSIONAL ECHOCARDIOGRAPHY STUDY
    Tanaka, Jun
    Saito, Takeji
    Furugen, Azusa
    Makkar, Raj
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1977 - E1977
  • [39] Cardiovascular Magnetic Resonance for the Evaluation of Aortic Regurgitation Following Transcatheter Aortic Valve Replacement: Insights on Clinical Outcomes
    Ribeiro, Henrique B.
    Orwat, Stefan
    Hayek, Salim S.
    Larose, Eric
    Babaliaros, Vasilis
    Dahou, Abdellaziz
    Pasian, Sergio
    Pibarot, Philippe
    Beaumont, Emilie Pelletier
    Campelo-Parada, Francisco
    Lerakis, Stamatios
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B49 - B49
  • [40] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Alexander Lenz
    Johannes Petersen
    Christoph Riedel
    Julius M. Weinrich
    Hendrik Kooijman
    Bjoern P. Schoennagel
    Gerhard Adam
    Yskert von Kodolitsch
    Hermann Reichenspurner
    Evaldas Girdauskas
    Peter Bannas
    Journal of Cardiovascular Magnetic Resonance, 22