Clinical Characterization of a Table Mounted Range Shifter Board for Synchrotron-Based Intensity Modulated Proton Therapy for Pediatric Craniospinal Irradiation

被引:0
|
作者
Hrinivich, William T. [1 ,2 ]
Li, Heng [1 ,2 ]
Tran, Anh [1 ,2 ]
Acharya, Sahaja [1 ,2 ]
Ladra, Matthew M. [1 ,2 ]
Sheikh, Khadija [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Johns Hopkins Proton Therapy Ctr, Sch Med, Washington, DC 20016 USA
关键词
craniospinal irradiation; pediatric radiotherapy; proton therapy; pencil beam scanning; image-guided radiotherapy; 2ND CANCERS; BEAM; MEDULLOBLASTOMA; REDUCTION; DELIVERY; SYSTEM; PHOTON; BOLUS; RISK;
D O I
10.3390/cancers15112882
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity modulated proton therapy provides unparalleled normal tissue sparing for the treatment of pediatric cancers such as medulloblastoma using craniospinal irradiation. However, proton delivery systems have a minimum deliverable energy and depth, requiring range shifter devices for the treatment of shallow targets and/or small anatomy. Standard range shifters are mounted to the treatment nozzle and introduce lateral scatter which, unfortunately, increases normal tissue dose. In this study we designed, manufactured, and characterized a range shifter board which rests directly under the patient during treatment to maintain a shallow treatment depth while minimizing lateral scatter, similar to previously proposed designs but optimized for our synchrotronbased delivery system. We present the dosimetric measurements we performed to characterize the device for treatment planning including severity of artifacts in on-board images. We compared the standard and range shifter board planning approaches in an anthropomorphic phantom and delivered the treatment plans to confirm the dosimetric differences. Finally, we compared treatment plans from two previously treated pediatric patients, demonstrating the ability to significantly reduce lung and kidney dose using this device compared to a standard range shifter. This device is now in routine use at our clinic. Purpose: To report our design, manufacturing, commissioning and initial clinical experience with a table-mounted range shifter board (RSB) intended to replace the machine-mounted range shifter (MRS) in a synchrotron-based pencil beam scanning (PBS) system to reduce penumbra and normal tissue dose for image-guided pediatric craniospinal irradiation (CSI). Methods: A custom RSB was designed and manufactured from a 3.5 cm thick slab of polymethyl methacrylate (PMMA) to be placed directly under patients, on top of our existing couch top. The relative linear stopping power (RLSP) of the RSB was measured using a multi-layer ionization chamber, and output constancy was measured using an ion chamber. End-to-end tests were performed using the MRS and RSB approaches using an anthropomorphic phantom and radiochromic film measurements. Cone beam CT (CBCT) and 2D planar kV X-ray image quality were compared with and without the RSB present using image quality phantoms. CSI plans were produced using MRS and RSB approaches for two retrospective pediatric patients, and the resultant normal tissue doses were compared. Results: The RLSP of the RSB was found to be 1.163 and provided computed penumbra of 6.9 mm in the phantom compared to 11.8 mm using the MRS. Phantom measurements using the RSB demonstrated errors in output constancy, range, and penumbra of 0.3%, 0.8%, and 0.6 mm, respectively. The RSB reduced mean kidney and lung dose compared to the MRS by 57.7% and 46.3%, respectively. The RSB decreased mean CBCT image intensities by 86.8 HU but did not significantly impact CBCT or kV spatial resolution providing acceptable image quality for patient setup. Conclusions: A custom RSB for pediatric proton CSI was designed, manufactured, modeled in our TPS, and found to significantly reduce lateral proton beam penumbra compared to a standard MRS while maintaining CBCT and kV image-quality and is in routine use at our center.
引用
收藏
页数:13
相关论文
共 40 条
  • [31] Highly Conformal Hybrid Forward and Inverse Planned Intensity Modulated Radiation Therapy for Supine Craniospinal Irradiation (CSI): Long-term Results and Implications for Pencil Beam Proton Planning
    Ahmed, S. K.
    Kruse, J. J.
    Beltran, C.
    Laack, N. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E557 - E557
  • [32] Feasibility study of range-based registration using daily cone beam CT for intensity-modulated proton therapy
    Yao, Weiguang
    Krasin, Matthew J.
    Farr, Jonathan B.
    Merchant, Thomas E.
    MEDICAL PHYSICS, 2018, 45 (03) : 1191 - 1203
  • [33] Study On Interfractional Range Reduction by Range-Based Registration Using Daily CBCT for Pelvic and Abdominal Sarcoma Patients Treated by Intensity-Modulated Proton Therapy
    Yao, W.
    Windmueller, R.
    Harikumar, V.
    Ates, O.
    Krasin, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E403 - E403
  • [34] Dosimetric evaluation of cone-beam CT-based synthetic CTs in pediatric patients undergoing intensity-modulated proton therapy
    Sheikh, Khadija
    Liu, Dezhi
    Li, Heng
    Acharya, Sahaja
    Ladra, Matthew M.
    Hrinivich, William T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [35] Intensity Modulated Proton Therapy for Bilateral Breast or Chest Wall and Comprehensive Nodal Irradiation for Synchronous Bilateral Breast Cancer: Initial Clinical Experience and Dosimetric Comparison
    Garda, Allison E.
    Hunzeker, Ashley E.
    Michel, Ann K.
    Fattahi, Sayeh
    Shiraishi, Satomi
    Remmes, Nicholas B.
    Schultz, Heather L.
    Harmsen, W. Scott
    Shumway, Dean A.
    Yan, Elizabeth S.
    Park, Sean S.
    Mutter, Robert W.
    Corbin, Kimberly S.
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)
  • [36] Explore the Potential Clinical and Dosimetric Improvements for Brain Cancer Proton Beam Treatment Based on the New Delivery and Planning Technique Developments - Collimator Based Intensity Modulated Proton Therapy and Spot-Scanning Proton Arc Therapy
    Ding, X.
    Li, X.
    Zhou, J.
    Stevens, C. W.
    Yan, D.
    Chinnaiyan, P.
    Kabolizadeh, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E490 - E490
  • [37] Clinical experience of craniospinal intensity-modulated spot-scanning proton therapy using large fields for central nervous system medulloblastomas and germ cell tumors in children, adolescents, and young adults
    Hashimoto, Takayuki
    Shimizu, Shinichi
    Takao, Seishin
    Terasaka, Shunsuke
    Iguchi, Akihiro
    Kobayashi, Hiroyuki
    Mori, Takashi
    Yoshimura, Takaaki
    Matsuo, Yuto
    Tamura, Masaya
    Matsuura, Taeko
    Ito, Yoichi M.
    Onimaru, Rikiya
    Shirato, Hiroki
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (04) : 527 - 537
  • [38] Toxicity and Survival Outcomes From Intensity Modulated Proton Therapy-Based Re-Irradiation in Patients With Non-Small Cell Lung Cancer
    Mohindra, P.
    Saeed, A.
    Vyfhuis, M. A. L.
    Scilla, K.
    Molitoris, J. K.
    Simone, C. B., II
    Rolfo, C.
    Mehra, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 112 (02): : E4 - E5
  • [39] Comparative Analysis of Strut-Based High-Dose-Rate Brachytherapy Versus Intensity Modulated Proton Therapy for Delivery of Accelerated Partial Breast Irradiation
    Chen, P. Y.
    Wang, Y.
    Zhou, J.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E630 - E631
  • [40] Pre-Clinical Evaluation of a Ring Gantry-Based Linac with a Dual-Layer Mlc for Total Marrow and Lymphoid Irradiation and Intensity-Modulated Total Body Irradiation for Pediatric Patients
    Han, C.
    Magliari, A.
    Rosa, L.
    Liu, B.
    Wong, J. Y. C.
    Williams, T. M.
    Liu, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E134 - E135