Quantification of underivatized amino acids in solid beverages using high-performance liquid chromatography and a potentiometric detector

被引:0
|
作者
Xu, Jiale [1 ]
Wang, Yutong [1 ]
Jiang, Junhui [1 ]
Li, Xiaomeng [1 ]
Xu, Yuheng [1 ]
Song, Wenjing [1 ]
机构
[1] Shenyang Med Coll, Sch Publ Hlth, Shenyang 110034, Peoples R China
关键词
Potentiometric detector; High-performance liquid chromatography; Polymeric membrane copper(ii)-electrode; Hyphenated technique; Amino acids; ION-SELECTIVE ELECTRODE; FLOW-INJECTION SYSTEM; CONTROLLED-RELEASE; CARBOXYLIC-ACIDS; HPLC; NUCLEOTIDES; ANIONS;
D O I
10.1016/j.chroma.2023.463986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simultaneous quantification of amino acids (AAs) in solid beverages without prior derivatization was explored by high-performance liquid chromatography (HPLC) coupled to a potentiometric detector. In-cluded were threonine, leucine, methionine, phenylalanine, and histidine. The potentiometric detector was made consisting of a copper(II)-selective electrode based on a polyvinyl chloride (PVC) membrane, and the potential changes in the detector were determined according to the coordination interactions between cupric copper ions released from the inner filling solution of the electrode and AAs. Condi-tions were optimized for effective separation and sensitive detection. Fundamental characteristics such as linearity, limits of detection, limits of quantitation, accuracy, precision, and robustness were validated experimentally. The calibration curves showed a linear relationship between peak heights and the injec-tion concentrations of the AAs. The detection limits down to the sub-micromolar range were achieved under isocratic conditions, outperforming ultraviolet detection. The copper(II)-selective electrode had a minimum lifetime of one month. Some real samples were examined to further demonstrate the feasi-bility of the proposed approach. The measurement results obtained by the present method were in good agreement with those obtained by the HPLC-mass spectrometry (MS), indicating that the combined HPLC-potentiometric method is a potential option for quantifying AAs.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Plasma amino acid quantification using High Performance Liquid Chromatography
    Malaver Ortega, Luis Fernando
    Javier Almeciga-Diaz, Carlos
    Morales Monsalve, Ines Stella
    Echeverri Pena, Olga Yaneth
    Guevara Morales, Johana
    Zuluaga Torres, Estefania
    Cordoba Ruiz, Henry Alirio
    Barrera Avellaneda, Luis Alejandro
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2009, 43 (04): : 647 - 661
  • [22] Analysis of free and peptide-bound amino acids using high-performance liquid chromatography
    Jia, Sichao
    Dahanayaka, Sudath
    Wu, Zhenlong
    Dai, Zhaolai
    Yang, Ying
    Wang, Junjun
    Wu, Guoyao
    AMINO ACIDS, 2013, 45 (03) : 590 - 591
  • [23] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PLASMA AMINO-ACIDS USING ORTHOPHTHALALDEHYDE DERIVATIZATION
    BLUNDELL, G
    BRYDON, WG
    CLINICA CHIMICA ACTA, 1987, 170 (01) : 79 - 83
  • [24] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ORGANIC-ACIDS WITH POTENTIOMETRIC DETECTION USING A METALLIC COPPER ELECTRODE
    HADDAD, PR
    ALEXANDER, PW
    TROJANOWICZ, M
    JOURNAL OF CHROMATOGRAPHY, 1984, 315 (DEC): : 261 - 270
  • [25] SEPARATION OF PHENYLTHIOHYDANTOIN AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PUCCI, P
    SANNIA, G
    MARINO, G
    JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV): : 371 - 377
  • [26] DANSYLATION OF AMINO-ACIDS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ANALYSIS
    TAPUHI, Y
    SCHMIDT, DE
    LINDNER, W
    KARGER, BL
    ANALYTICAL BIOCHEMISTRY, 1981, 115 (01) : 123 - 129
  • [27] ON THE ANALYSIS OF PHENYLTHIOHYDANTOIN AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GODTFREDSEN, SE
    OLIVER, RWA
    CARLSBERG RESEARCH COMMUNICATIONS, 1980, 45 (01) : 35 - 46
  • [28] SEPARATION OF PHOSPHORYLATED AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KUMAREV, VP
    MITINA, RL
    MOROZOVA, TM
    BIOORGANICHESKAYA KHIMIYA, 1986, 12 (01): : 54 - 58
  • [29] Automated method for the measurement of amino acids in urine by high-performance liquid chromatography
    Carducci, C
    Birarelli, M
    Leuzzi, V
    Santagata, G
    Serafini, P
    Antonozzi, I
    JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 173 - 180
  • [30] DETERMINATION OF FREE AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SCHUSTER, R
    ANALYTICAL CHEMISTRY, 1980, 52 (04) : 617 - 620