Quantification of underivatized amino acids in solid beverages using high-performance liquid chromatography and a potentiometric detector

被引:0
|
作者
Xu, Jiale [1 ]
Wang, Yutong [1 ]
Jiang, Junhui [1 ]
Li, Xiaomeng [1 ]
Xu, Yuheng [1 ]
Song, Wenjing [1 ]
机构
[1] Shenyang Med Coll, Sch Publ Hlth, Shenyang 110034, Peoples R China
关键词
Potentiometric detector; High-performance liquid chromatography; Polymeric membrane copper(ii)-electrode; Hyphenated technique; Amino acids; ION-SELECTIVE ELECTRODE; FLOW-INJECTION SYSTEM; CONTROLLED-RELEASE; CARBOXYLIC-ACIDS; HPLC; NUCLEOTIDES; ANIONS;
D O I
10.1016/j.chroma.2023.463986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simultaneous quantification of amino acids (AAs) in solid beverages without prior derivatization was explored by high-performance liquid chromatography (HPLC) coupled to a potentiometric detector. In-cluded were threonine, leucine, methionine, phenylalanine, and histidine. The potentiometric detector was made consisting of a copper(II)-selective electrode based on a polyvinyl chloride (PVC) membrane, and the potential changes in the detector were determined according to the coordination interactions between cupric copper ions released from the inner filling solution of the electrode and AAs. Condi-tions were optimized for effective separation and sensitive detection. Fundamental characteristics such as linearity, limits of detection, limits of quantitation, accuracy, precision, and robustness were validated experimentally. The calibration curves showed a linear relationship between peak heights and the injec-tion concentrations of the AAs. The detection limits down to the sub-micromolar range were achieved under isocratic conditions, outperforming ultraviolet detection. The copper(II)-selective electrode had a minimum lifetime of one month. Some real samples were examined to further demonstrate the feasi-bility of the proposed approach. The measurement results obtained by the present method were in good agreement with those obtained by the HPLC-mass spectrometry (MS), indicating that the combined HPLC-potentiometric method is a potential option for quantifying AAs.(c) 2023 Elsevier B.V. All rights reserved.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [1] QUANTIFICATION OF CAFFEINE IN BEVERAGES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEANDRADE, JB
    PINHEIRO, HLC
    LOPES, WA
    MARTINS, S
    AMORIM, AMM
    BRANDAO, AM
    QUIMICA NOVA, 1995, 18 (04): : 379 - 381
  • [2] APPLICATION OF A COPPER TUBULAR ELECTRODE AS A POTENTIOMETRIC DETECTOR IN THE DETERMINATION OF AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ALEXANDER, PW
    HADDAD, PR
    LOW, GKC
    MAITRA, C
    JOURNAL OF CHROMATOGRAPHY, 1981, 209 (01): : 29 - 39
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF DERIVATIZED AND UNDERIVATIZED AMINO-ACIDS
    GAMES, DE
    RAMSEY, ED
    JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01): : 67 - 79
  • [4] ENANTIOMERIC SEPARATION OF UNDERIVATIZED ALPHA-METHYL-ALPHA-AMINO ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WEINSTEIN, S
    GRINBERG, N
    JOURNAL OF CHROMATOGRAPHY, 1985, 318 (01): : 117 - 121
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF UNDERIVATIZED GANGLIOSIDES
    ANDO, S
    WAKI, H
    KON, K
    JOURNAL OF CHROMATOGRAPHY, 1987, 408 : 285 - 290
  • [6] RESOLUTION OF UNDERIVATIZED 2-HYDROXY ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BENECKE, I
    JOURNAL OF CHROMATOGRAPHY, 1984, 291 (MAY): : 155 - 164
  • [7] Separation of the enantiomers of underivatized amino acids by using serially connected dual column high-performance liquid chromatography-tandem mass spectrometry
    Oztepe, Tugce
    Kale, Nermin Busra
    Recber, Tuba
    Baysal, Ipek
    Yabanoglu-Ciftci, Samiye
    Gumustas, Mehmet
    Kir, Sedef
    Chankvetadze, Bezhan
    Nemutlu, Emirhan
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1683
  • [8] Direct determination of 14 underivatized amino acids in leech by reversed phase high performance liquid chromatography
    Yan Dan
    Li Guo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 705 - 708
  • [9] SEPARATION OF AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BAYER, E
    GROM, E
    KALTENEGGER, B
    UHMANN, R
    ANALYTICAL CHEMISTRY, 1976, 48 (08) : 1106 - 1109
  • [10] SEPARATION OF PHENYLTHIOHYDANTOIN AMINO ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ANNAN, WD
    JOURNAL OF CHROMATOGRAPHY, 1979, 173 (01): : 194 - 197