Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction

被引:0
|
作者
Kang, Hyo-Jin [1 ,2 ]
Lee, Jeong Min [1 ,2 ,3 ]
Park, Sae Jin [4 ]
Lee, Sang Min [5 ]
Joo, Ijin [1 ,2 ]
Yoon, Jeong Hee [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[4] G&E Alphadom Med Ctr, Dept Radiol, Seongnam, South Korea
[5] Cha Gangnam Med Ctr, Dept Radiol, Seoul, South Korea
关键词
Deep learning image reconstruction; CT; Image quality; Radiation dose; Iterative reconstruction; Abdomen; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; ALGORITHM; REDUCTION; NOISE; CHEST;
D O I
10.2174/1573405620666230525104809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Whether deep learning-based CT reconstruction could improve lesion conspicuity on abdominal CT when the radiation dose is reduced is controversial. Objectives: To determine whether DLIR can provide better image quality and reduce radiation dose in contrast- enhanced abdominal CT compared with the second generation of adaptive statistical iterative reconstruction (ASiR-V). Aims: This study aims to determine whether deep-learning image reconstruction (DLIR) can improve image quality. Methods: In this retrospective study, a total of 102 patients were included, who underwent abdominal CT using a DLIR-equipped 256-row scanner and routine CT of the same protocol on the same vendor's 64- row scanner within four months. The CT data from the 256-row scanner were reconstructed into ASiR-V with three blending levels (AV30, AV60, and AV100), and DLIR images with three strength levels (DLIR-L, DLIR-M, and DLIR-H). The routine CT data were reconstructed into AV30, AV60, and AV100. The contrast-to-noise ratio (CNR) of the liver, overall image quality, subjective noise, lesion conspicuity, and plasticity in the portal venous phase (PVP) of ASiR-V from both scanners and DLIR were compared. Results: The mean effective radiation dose of PVP of the 256-row scanner was significantly lower than that of the routine CT (6.3 +/- 2.0 mSv vs. 2.4 +/- 0.6 mSv; p< 0.001). The mean CNR, image quality, subjective noise, and lesion conspicuity of ASiR-V images of the 256-row scanner were significantly lower than those of ASiR-V images at the same blending factor of routine CT, but significantly improved with DLIR algorithms. DLIR-H showed higher CNR, better image quality, and subjective noise than AV30 from routine CT, whereas plasticity was significantly better for AV30. Conclusion: DLIR can be used for improving image quality and reducing radiation dose in abdominal CT, compared with ASIR-V.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [32] A study of using a deep learning image reconstruction to improve the image quality of extremely low-dose contrast-enhanced abdominal CT for patients with hepatic lesions
    Cao, Le
    Liu, Xiang
    Li, Jianying
    Qu, Tingting
    Chen, Lihong
    Cheng, Yannan
    Hu, Jieliang
    Sun, Jingtao
    Guo, Jianxin
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118):
  • [33] Evaluation of Abdominal CT Obtained Using a Deep Learning-Based Image Reconstruction Engine Compared with CT Using Adaptive Statistical Iterative Reconstruction
    Yoo, Yeo Jin
    Choi, In Young
    Yeom, Suk Keu
    Cha, Sang Hoon
    Jung, Yunsub
    Han, Hyun Jong
    Shim, Euddeum
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2022, 106 (01):
  • [34] First Results of a New Deep Learning Reconstruction Algorithm on Image Quality and Liver Metastasis Conspicuity for Abdominal Low-Dose CT
    Greffier, Joel
    Durand, Quentin
    Serrand, Chris
    Sales, Renaud
    de Oliveira, Fabien
    Beregi, Jean-Paul
    Dabli, Djamel
    Frandon, Julien
    DIAGNOSTICS, 2023, 13 (06)
  • [35] The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT
    Kalmar, Peter I.
    Quehenberger, Franz
    Steiner, Juergen
    Lutfi, Andre
    Bohlsen, Dennis
    Talakic, Emina
    Hassler, Eva Maria
    Schoellnast, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1416 - 1420
  • [36] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Jinhua Wang
    Xin Sui
    Ruijie Zhao
    Huayang Du
    Jiaru Wang
    Yun Wang
    Ruiyao Qin
    Xiaoping Lu
    Zhuangfei Ma
    Yinghao Xu
    Zhengyu Jin
    Lan Song
    Wei Song
    European Radiology, 2024, 34 : 1053 - 1064
  • [37] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Wang, Jinhua
    Sui, Xin
    Zhao, Ruijie
    Du, Huayang
    Wang, Jiaru
    Wang, Yun
    Qin, Ruiyao
    Lu, Xiaoping
    Ma, Zhuangfei
    Xu, Yinghao
    Jin, Zhengyu
    Song, Lan
    Song, Wei
    EUROPEAN RADIOLOGY, 2024, 34 (02) : 1053 - 1064
  • [38] Deep Learning with Adaptive Hyper-Parameters for Image Reconstruction in Low-Dose CT
    Ding, Q.
    Gao, H.
    Ji, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E392 - E392
  • [39] A dataset-free deep learning method for low-dose CT image reconstruction
    Ding, Qiaoqiao
    Ji, Hui
    Quan, Yuhui
    Zhang, Xiaoqun
    INVERSE PROBLEMS, 2022, 38 (10)
  • [40] Deep Learning With Adaptive Hyper-Parameters for Low-Dose CT Image Reconstruction
    Ding, Qiaoqiao
    Nan, Yuesong
    Gao, Hao
    Ji, Hui
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 648 - 660