MoS2 nanosheets based label-free colorimetric aptasensor for Escherichia coli O157: H7 detection

被引:9
|
作者
Li, Jiye [1 ,2 ]
Yun, Wen [3 ]
Zhang, Hua [1 ,2 ]
Chen, Ligang [1 ,2 ]
Ho, Ho-Pui [6 ]
Pu, Xiaoyin [1 ,2 ]
Huang, Yu [1 ,2 ]
Shen, Yu [4 ,5 ]
Cao, Haiyan [7 ,8 ]
机构
[1] Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Chongqing 400714, Peoples R China
[2] Univ Chinese Acad Sci, Chongqing Sch, Chongqing 400714, Peoples R China
[3] Chongqing Technol & Business Univ, Coll Environm & Resources, Chongqing Key Lab Catalysis & New Environm Mat, Chongqing 400067, Peoples R China
[4] Chongqing Technol & Business Univ, Chongqing Key Lab Catalysis & New Environm Mat, Cooperat Intelligent Mfg Serv, Natl Base Int Sci & Technol, Chongqing 400067, Peoples R China
[5] Chongqing South Thais Environm Protect Technol Res, Chongqing 400060, Peoples R China
[6] Chinese Univ Hong Kong, Dept Biomed Engn, Shatin, Hong Kong, Peoples R China
[7] Yangtze Normal Univ, Key Lab Chongqing Inorgan Special Funct Mat, Chongqing 408100, Peoples R China
[8] Yangtze Normal Univ, Coll Chem & Chem Engn, Chongqing 408100, Peoples R China
关键词
MoS2; nanosheet; Sonication-assisted exfoliation; Pathogens detection E. coli O157: H7; GOLD NANOPARTICLES; AGGREGATION KINETICS; NANOSTRUCTURES; BIOSENSOR; ASSAY;
D O I
10.1016/j.colsurfa.2023.131955
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aggregation behavior of large-scale two-dimensional molybdenum disulfide (MoS2) nanosheets prepared by sonication-assisted exfoliation in environmental friendly 45% ethanol/water mixture under different conditions for biological sensing application. Adjustment of sonication time and centrifuging speed could be utilized to select MoS2 nanosheets with various concentrations and sizes. Higher concentrations of salt and cations with higher valence were more effective to aggregate MoS2 nanosheets and settle them than their counterparts, which could be attributed to the perturbation of attractive van der Waals forces and repulsive Coulombic interactions. Moreover, the ethanol in mixture was capable of assisting MoS2 nanosheets to resist this aggregation initiated by salt but it would disturb the stability of aptamer functionalized MoS2 nanosheets in salt solution. The interplay of Escherichia coli O157: H7 (E. coli O157:H7) aptamer functionalized MoS2 nanosheets and salt was then inspired to develop a high sensitive detection method of E. coli O157:H7. The introduction of target bacteria induced MoS2 nanosheets to be exposed to cations, and promoted the aggregation and sedimentation behavior of MoS2 nanosheets. The change in extinction of MoS2 nanosheets had a linear relationship with E. coli O157:H7 concentration in a range of 500-5000 CFU/mL with a detection limit of 116 CFU/mL. This proposed colorimetric sensor expands the application scope of MoS2 nanosheets and shows its promising potential as an alternative tool for bacteria detection in food and water quality monitoring.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Prevalence of Escherichia coli O157:H7
    Dekoninck, A
    Blaton, B
    Lontie, M
    Verhaegen, J
    ACTA CLINICA BELGICA, 1998, 53 (01): : 55 - 56
  • [32] Escherichia coli O157:H7 in milk
    Kirk, JH
    Price, S
    Wright, JC
    LARGE ANIMAL PRACTICE, 1997, 18 (02): : 16 - +
  • [33] Rapid and Ultrasensitive Colorimetric Biosensors for Onsite Detection of Escherichia coli O157:H7 in Fluids
    Pan, Bofeng
    El-Moghazy, Ahmed Y.
    Norwood, Makela
    Nitin, Nitin
    Sun, Gang
    ACS SENSORS, 2024, 9 (02) : 912 - 922
  • [34] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868
  • [35] Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor
    Uda, Muhammad Nur Afnan
    Dafhalla, Alaa Kamal Yousif
    Dhahi, Thikra S.
    Adam, Tijjani
    Gopinath, Subash Chandra Bose
    Ambek, Asral Bahari
    Uda, Muhammad Nur Aiman
    Mohammed, Mohammed
    Parmin, Nor Azizah
    Ibrahim, Nur Hulwani
    Hashim, Uda
    HELIYON, 2024, 10 (05)
  • [36] Label free-based proteomic analysis of Escherichia coli O157:H7 subjected to ohmic heating
    Tian, Xiaojing
    Liu, Yi
    Yu, Qianqian
    Shao, Lele
    Li, Xingmin
    Dai, Ruitong
    FOOD RESEARCH INTERNATIONAL, 2020, 128
  • [37] Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor
    Soheili, Vahid
    Taghdisi, Seyed Mohammad
    Abnous, Khalil
    Ebrahimi, Mohsen
    IRANIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2020, 23 (07) : 901 - 908
  • [38] Modification of methods for detection of Escherichia coli O157:H7 on produce
    Se-Ri Kim
    Yohan Yoon
    Min-Kyoung Seo
    Won-Il Kim
    Won-Bo Shim
    Duck Hwa Chung
    Jong Chul Yun
    Kyoung Yul Ryu
    Byung-Seok Kim
    Food Science and Biotechnology, 2014, 23 : 1349 - 1356
  • [39] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Vidova, Barbora
    Tothova, Eva
    Blahut, L'uboslav
    Horvathova, Viera
    Godany, Andrej
    BIOLOGIA, 2011, 66 (03) : 401 - 405
  • [40] Electrochemical biosensors for rapid detection of Escherichia coli O157:H7
    Xu, Meng
    Wang, Ronghui
    Li, Yanbin
    TALANTA, 2017, 162 : 511 - 522