Research on the Influence of Pantograph Catenary Contact Loss Arcs and Zero-Crossing Stage on Electromagnetic Disturbance in High-Speed Railway

被引:3
|
作者
Yang, Yixuan [1 ]
Cao, Hefei [2 ]
Zhang, Mingzhi [2 ]
Su, Zhiguo [2 ]
Hu, Man [3 ]
Jin, Mengzhe [4 ]
Liu, Shanghe [5 ]
机构
[1] Shijiazhuang Tiedao Univ, Hebei Key Lab Electromagnet Environm Effects & Inf, Shijiazhuang 050043, Peoples R China
[2] CRSC Res & Design Inst Grp Co Ltd, Beijing 100070, Peoples R China
[3] Beijing Inst Technol, Sch Mech & Elect Engn, Beijing 100081, Peoples R China
[4] Shijiazhuang Tiedao Univ, Sch Informat Sci & Technol, Shijiazhuang 050043, Peoples R China
[5] Shijiazhuang Tiedao Univ, Res Ctr Electromagnet Environm Effects, Shijiazhuang 050043, Peoples R China
关键词
pantograph catenary contact loss; electric arc; discharge; electromagnetic radiation; zero-crossing stage; high speed railway; train control system; LINE;
D O I
10.3390/en17010138
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
During train travel, various factors, such as body vibration, uneven contact lines, and hard spots on carbon sliding plates and over electric neutral zones, often lead to brief separation between the pantograph and the contact line, i.e., the pantograph catenary contact loss phenomenon. With the continuous increase in train speed and traction power, the probability of pantograph catenary contact loss occurrences rises with a gradual increase in the energy of electromagnetic radiation, making the pantograph catenary arc a primary source of interference affecting the electromagnetic safety of high-speed railways. Understanding the mechanism, characteristics, and influencing factors of electromagnetic interference caused by pantograph catenary contact loss discharges is of utmost importance for analyzing and resolving on-site equipment interference faults. Our analysis of the physical process of pantograph catenary contact loss reveals that when the distance between the pantograph and catenary is significant and the duration is lengthy, high-voltage breakdown occurs within the pantograph catenary gap as it comes close again after the complete extinguishing of the arc. To investigate the electromagnetic radiation characteristics resulting from high-voltage breakdown discharge arcs in the pantograph catenary contact loss process, we established a laboratory test platform for assessing the electromagnetic disturbance characteristics of high-voltage pantograph discharge. We designed a test procedure utilizing fixed-gap breakdown discharge to evaluate the impact of the arc zero-crossing stage on electromagnetic radiation disturbances. Our research indicates that when the pantograph catenary spacing remains constant, an increase in voltage level leads to an elevation in the current within the discharge circuit, resulting in an increased intensity of impulse radiation generated during pantograph catenary contact loss events. During the moment of gap breakdown, the antenna records the highest amplitude of electromagnetic radiation. Also, during the steady-state arc ignition phase of the pantograph catenary gap, the zero-crossing stage generates pulsed discharge currents within the circuit, accompanied by substantial electromagnetic radiation. As the arc current increases, the zero-crossing time shortens, and the pulse current during the zero-crossing process decreases, accompanied by a reduction in the excited electromagnetic radiation. These observations reveal novel characteristics of electromagnetic radiation disturbances during steady-state arc ignition. The outcomes of our study provide valuable insights that can contribute to our understanding of the characteristics and influencing factors of electromagnetic radiation in pantograph catenary contact loss discharges and offer theoretical guidance for the resolution of pantograph catenary contact loss interference faults.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Influence of pantograph suspension characteristics on the contact quality with the catenary for high speed trains
    Pombo, J.
    Ambrosio, J.
    [J]. COMPUTERS & STRUCTURES, 2012, 110 : 32 - 42
  • [22] Lightning Protection Research and Simulation of High-speed Railway Catenary
    Zheng Xue-xian
    Wang Xun
    Cheng Hong-bo
    Cao Wen-hui
    [J]. MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1707 - 1711
  • [23] Research on fine adjustment quota of catenary of high-speed railway
    Zhang, Tong-Lin
    [J]. Journal of Railway Engineering Society, 2013, 30 (05) : 82 - 86
  • [24] Research on Dynamic Performance and Parameter Optimization of the High-Speed Pantograph and Catenary System
    Wang, Xinying
    Nian, Xiaohong
    Chu, Xiaoyan
    Yue, Pengchao
    [J]. 2017 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-HARBIN), 2017, : 486 - 491
  • [25] Influence of the aerodynamic forces on the pantograph-catenary system for high-speed trains
    Pombo, J.
    Ambrosio, J.
    Pereira, M.
    Rauter, F.
    Collina, A.
    Facchinetti, A.
    [J]. VEHICLE SYSTEM DYNAMICS, 2009, 47 (11) : 1327 - 1347
  • [26] Study of dynamic buckling in droppers of high-speed railway line catenary during pantograph passage
    Bucca, Giuseppe
    Collina, Andrea
    Diana, Giorgio
    Zappa, Emanuele
    Di Flauro, Mario
    Iacomelli, Alessio
    Spalvieri, Claudio
    [J]. Ingegneria Ferroviaria, 2022, 77 (12): : 937 - 961
  • [27] Influence of a high-speed train passing through a tunnel on pantograph aerodynamics and pantograph-catenary interaction
    Li, Ruiping
    Zhang, Weihua
    Ning, Zhou
    Liu, Binbin
    Zou, Dong
    Liu, Wei
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2017, 231 (02) : 198 - 210
  • [28] Loss Fault Detection for Auxiliary Catenary Wire of High-speed Railway Catenary Wire Holder
    [J]. Liu, Zhigang (liuzg@swjtu.cn), 1600, Science Press (39):
  • [29] Servo actuated railway pantograph for high-speed running with constant contact force
    Galeotti, G.
    Galanti, M.
    Magrini, S.
    Toni, P.
    [J]. Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 1993, 207 (01) : 37 - 49
  • [30] Effect of Pantograph's Main Structure on the Contact Quality in High-Speed Railway
    Wang, Jiangwen
    Mei, Guiming
    [J]. SHOCK AND VIBRATION, 2021, 2021