Factors for failure of ultrasound-guided compression repair for femoral pseudoaneurysms after neuroendovascular therapy

被引:0
|
作者
Hata, Hidenobu [1 ]
Ikeda, Hiroyuki [1 ]
Ishibashi, Ryota [1 ,2 ]
Kaneko, Ryosuke [1 ]
Fujiwara, Toshio [1 ]
Uezato, Minami [1 ]
Kinosada, Masanori [1 ]
Kurosaki, Yoshitaka [1 ]
Chin, Masaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Neurosurg, 1-1-1 Miwa, Kurashiki, Okayama 7108602, Japan
[2] Kitano Hosp, Tazuke Kofukai Med Res Inst, Dept Neurosurg, Osaka, Japan
来源
NEURORADIOLOGY JOURNAL | 2023年 / 36卷 / 06期
关键词
Femoral artery; neuroendovascular therapy; ultrasound-guided compression repair; pseudoaneurysm; ARTERY PSEUDOANEURYSMS; EXPERIENCE; CLOSURE; DEVICE;
D O I
10.1177/19714009231177382
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objective Pseudoaneurysms are a serious complication of neuroendovascular therapy with femoral artery puncture, for which ultrasound-guided compression repair (UGCR) is often the first choice of radical therapy. We sought to retrospectively investigate the factors for failure of UGCR for pseudoaneurysm at the femoral artery puncture site. Methods Among patients undergoing neuroendovascular therapy with femoral artery puncture at our hospital between January 2018 and April 2021, those who received a diagnosis of pseudoaneurysm and underwent UGCR were enrolled. They were classified into two groups according to whether UGCR was successful (UGCR group) or was converted to surgical repair (SR group). Patient and procedural characteristics were compared between the two groups. Results During the study period, 577 patients underwent neuroendovascular therapy with femoral artery puncture, 10 of whom (1.7%) received a diagnosis of pseudoaneurysm and underwent UGCR. There were seven patients in the UGCR group and three patients in the SR group. The sheath diameter tended to be larger in the SR group than in the UGCR group (p = 0.16). The modified Rankin scale score when a diagnosis of pseudoaneurysm was made was significantly lower in the SR group than in the UGCR group (1 [0-2] vs. 3 [2-5], p = 0.037). Conclusions Physical activity may be associated with failure of UGCR. In patients with high physical activity, the use of sedatives and analgesics to keep them at rest during puncture site compression after UGCR may lead to successful UGCR.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 50 条
  • [31] Prognostic factors in the recanalization of iatrogenic femoral artery pseudoaneurysms after treatment with percutaneous ultrasound-guided thrombin injection
    Ryan, AG
    Padilla-Thornton, AE
    Ryan, RS
    Chang, SD
    Zwirewich, CV
    Spielmann, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 108 - 109
  • [32] Ultrasound-guided compression repair and beyond
    Chatterjee, T
    Meier, B
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (01): : 16 - 16
  • [33] Doppler ultrasound-guided percutaneous thrombin injection for treating femoral pseudoaneurysms
    Miranda, Frederico Celestino
    Garcia, Rodrigo Gobbo
    Macedo Filho, Carlos Leite
    Mendes, Guilherme Falleiros
    de Andrade, Juliano Ribeiro
    Maurano, Alexandre
    Francisco Neto, Miguel Jose
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2008, 6 (04): : 428 - 433
  • [34] Minimal-invasive treatment of pseudoaneurysms of the femoral artery by ultrasound-guided aspiration-reinjection repair
    Petzsch, M
    Rehders, T
    Ince, H
    Eckard, H
    Kische, S
    Nienaber, CA
    CIRCULATION, 2005, 112 (17) : U674 - U674
  • [35] Ultrasound-Guided Fibrin Glue Injection for Treatment of Iatrogenic Femoral Pseudoaneurysms
    Gummerer, Maria
    Kummann, Moritz
    Gratl, Alexandra
    Haller, Daniela
    Frech, Andreas
    Klocker, Josef
    Fraedrich, Gustav
    Gruber, Hannes
    VASCULAR AND ENDOVASCULAR SURGERY, 2020, 54 (06) : 497 - 503
  • [36] Ultrasound-guided thrombin injection of iatrogenic femoral pseudoaneurysms: A prospective analysis
    Sackett, WR
    Taylor, SM
    Coffey, CB
    Viers, KD
    Langan, EM
    Cull, DL
    Snyder, BA
    Sullivan, TM
    AMERICAN SURGEON, 2000, 66 (10) : 937 - 940
  • [37] Treatment of latrogenic femoral pseudoaneurysm by ultrasound-guided compression therapy and thrombin injection
    Luedde, Mark
    Krumsdorf, Ulrike
    Zehelein, Joerg
    Ivandic, Boris
    Dengler, Thomas
    Katus, Hugo A.
    Tiefenbacher, Christiane
    ANGIOLOGY, 2007, 58 (04) : 435 - 439
  • [38] NEW ASPECTS IN ULTRASOUND-GUIDED COMPRESSION REPAIR OF POSTCATHETERIZATION FEMORAL-ARTERY INJURIES
    SCHAUB, F
    THEISS, W
    HEINZ, M
    ZAGEL, M
    SCHOMIG, A
    CIRCULATION, 1994, 90 (04) : 1861 - 1865
  • [39] Ultrasound-guided compression of femoral pseudoaneurysm: an audit of practice
    Chua, TP
    Howling, SJ
    Wright, C
    Fox, KM
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 63 (03) : 245 - 250
  • [40] Ultrasound-guided percutaneous thrombin injection for treatment of femoral pseudoaneurysms: technical note