Real-Time Monitoring and Modulation of Blood Pressure in a Rabbit Model of Ischemic Stroke

被引:1
|
作者
Alexander, Matthew D. [1 ,2 ]
Hoareau, Guillaume [3 ]
Zabriskie, Matthew S. [1 ]
Palatinus, Helen [3 ]
Chakravarthula, Nitin R. [3 ]
Wang, Chuanzhuo [4 ]
Johnson, M. Austin [3 ]
机构
[1] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Neurosurg, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Emergency Med, Salt Lake City, UT USA
[4] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
来源
基金
美国国家卫生研究院;
关键词
D O I
10.3791/64672
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Control of blood pressure, in terms of both absolute values and its variability, affects outcomes in ischemic stroke patients. However, it remains challenging to identify the mechanisms that lead to poor outcomes or evaluate measures by which these effects can be mitigated because of the prohibitive limitations inherent to human data. In such cases, animal models can be utilized to conduct rigorous and reproducible evaluations of diseases. Here we report refinement of a previously described model of ischemic stroke in rabbits that is augmented with continuous blood pressure recording to assess the impacts of modulation on blood pressure. Under general anesthesia, femoral arteries are exposed through surgical cutdowns to place arterial sheaths bilaterally. Under fluoroscopic visualization and roadmap guidance, a microcatheter is advanced into an artery of the posterior circulation of the brain. An angiogram is performed by injecting the contralateral vertebral artery to confirm occlusion of the target artery. With the occlusive catheter remaining in position for a fixed duration, blood pressure is continuously recorded to allow for tight titration of blood pressure manipulations, whether through mechanical or pharmacological means. At the completion of the occlusion interval, the microcatheter is removed, and the animal is maintained under general anesthesia for a prescribed length of reperfusion. For acute studies, the animal is then euthanized and decapitated. The brain is harvested and processed to measure the infarct volume under light microscopy and further assessed with various histopathological stains or spatial transcriptomic analysis. This protocol provides a reproducible model that can be utilized for more thorough preclinical studies on the effects of blood pressure parameters during ischemic stroke. It also facilitates effective preclinical evaluation of novel neuroprotective interventions that might improve care for ischemic stroke patients.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Wearable Pulse Wave Sensor and Interface for Real-Time Dynamic Blood Pressure Monitoring
    Li, Huimin
    Li, Anqi
    Zhou, Zhongyi
    Jiang, Bowei
    Yang, Qi
    Liu, Xinghui
    Wang, Kai
    2021 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2021,
  • [22] A Continuous Opto-Electronic Sensor for Blood Pressure Monitoring with Real-Time System
    Kao, Yung-Hua
    Chao, Paul C. -P.
    Wey, Chin-Long
    PROCEEDINGS OF THE ASME 26TH ANNUAL CONFERENCE ON INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 2017,
  • [23] TIME OF BLOOD PRESSURE IN TARGET RANGE IN ACUTE ISCHEMIC STROKE
    Kakaletsis, Nikolaos
    Ntaios, George
    Milionis, Haralampos
    Protogerou, Athanasios
    Karagiannaki, Anastasia
    Chouvarda, Ioanna
    Dourliou, Vasiliki
    Ladakis, Ioannis
    Kaiafa, Georgia
    Daios, Stylianos
    Doumas, Michael
    Savopoulos, Christos
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E297 - E297
  • [24] Time of blood pressure in target range in acute ischemic stroke
    Kakaletsis, Nikolaos
    Ntaios, George
    Milionis, Haralampos
    Protogerou, Athanasios D.
    Karagiannaki, Anastasia
    Chouvarda, Ioanna
    Dourliou, Vasiliki
    Ladakis, Ioannis
    Kaiafa, Georgia
    Daios, Stylianos
    Doumas, Michael
    Savopoulos, Christos
    JOURNAL OF HYPERTENSION, 2023, 41 (02) : 303 - 309
  • [25] Real-time ischemic condition monitoring in normoglycemic and hyperglycemic rats
    Choi, Samjin
    Kang, Sung Wook
    Lee, Gi-Ja
    Choi, Seok Keun
    Chae, Su-Jin
    Park, Hun-Kuk
    Chung, Joo-Ho
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (03) : 439 - 450
  • [26] Continuous emergency department blood pressure monitoring in acute ischemic stroke
    Stead, LG
    Gilmore, RM
    Vedula, KC
    Weaver, AL
    Decker, WW
    Brown, RD
    NEUROLOGY, 2005, 64 (06) : A305 - A305
  • [27] ACUTE ISCHEMIC STROKE DURING AMBULATORY BLOOD-PRESSURE MONITORING
    NUNES, JP
    FARIA, MD
    POLONIA, JJ
    LANCET, 1992, 339 (8801): : 1113 - 1114
  • [28] EVALUATION OF THE EFFICACY OF REAL-TIME INTRAVESICAL PRESSURE SENSOR IN RABBIT
    Sun, Young C.
    Jin, Su K.
    Jin, Woong B.
    Jin, Hyuk C.
    Hoo, Sung H.
    Youl, Ji L.
    Tae-Kon, H.
    Woong, Sae K.
    INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 : 378 - 378
  • [29] A Lightweight Model for Real-Time Monitoring of Ships
    Xing, Bowen
    Wang, Wei
    Qian, Jingyi
    Pan, Chengwu
    Le, Qibo
    ELECTRONICS, 2023, 12 (18)
  • [30] Implantable Biosensors for Real-time Strain and Pressure Monitoring
    Tan, Ee Lim
    Pereles, Brandon D.
    Horton, Brock
    Shao, Ranyuan
    Zourob, Mohammed
    Ong, Keat Ghee
    SENSORS, 2008, 8 (10) : 6396 - 6406