Fourier coded aperture transform hyperspectral imaging system

被引:8
|
作者
Xie, Hui [1 ]
Lu, Jun [1 ]
Han, Jing [1 ]
Zhang, Yi [1 ]
Xiong, Fengchao [1 ]
Zhao, Zhuang [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect Engn & Optoelect Technol, Nanjing 210094, Peoples R China
基金
中国博士后科学基金;
关键词
HADAMARD; DESIGN;
D O I
10.1016/j.optlaseng.2022.107443
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We consider using Fourier coded aperture transform to solve the acquisition and reconstruction problem of three-dimensional (3-D) hyperspectral imaging. In recent years, Coded aperture snapshot spectral imaging (CASSI) system has received increasing attention. However, reconstruction errors are unavoidable due to its ill-posed problems and the number of dispersion channels is limited. The Hadamard transform spectral (HTS) imaging method has no limitation on the number of dispersion channels, but it usually requires a long data acquisition time. By exploring the process of coded spectral imaging, in this paper, we propose Fourier coded aperture transform spectral imaging (FCTS). We compared the performance of HTS and FCTS by theoretical analysis and experiments. The results show that FCTS has better concentrated energy than HTS on natural hyperspectral data. Compared with the Hadamard transform method, the Fourier basis mode has better physical correlation with the natural image, and the reconstruction quality of FCTS is better than that of HTS in the case of under-sampling.
引用
收藏
页数:14
相关论文
共 50 条
  • [2] Column coded scanning aperture hyperspectral imaging system
    Shi, Yingchao
    Xiao, Xingchen
    Tong, Geng
    Zhang, Luming
    Chen, Fei
    Zhang, Wei
    Yu, Yiting
    OPTICS EXPRESS, 2023, 31 (22) : 37229 - 37240
  • [3] Quantum noise of Fourier-coded aperture imaging system
    Chou, Chien, 1600, JJAP, Minato-ku, Japan (33):
  • [4] CODED APERTURE IMAGING - A FOURIER SPACE ANALYSIS
    NUGENT, KA
    APPLIED OPTICS, 1987, 26 (03): : 563 - 569
  • [5] QUANTUM-NOISE OF FOURIER-CODED APERTURE IMAGING-SYSTEM
    CHOU, C
    KING, HJ
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (4A): : 2072 - 2078
  • [6] Hyperspectral imaging system calibration using image translations and Fourier transform
    Gorretta, Nathalie
    Rabatel, Gires
    Roger, Jean-Michel
    Fiorio, Christophe
    Lelong, Camille
    Bellon-Maurel, Veronique
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2008, 16 (04) : 371 - 380
  • [7] FOURIER CODED APERTURE IMAGING IN NUCLEAR-MEDICINE
    CHOU, C
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 454 : 457 - 464
  • [8] STATIC FOURIER TRANSFORM HYPERSPECTRAL IMAGING POLARIMETER
    Li, Jie
    Qi, Chun
    Zhu, Jingping
    Liao, Wenzhi
    Philips, Wilfried
    2016 8TH WORKSHOP ON HYPERSPECTRAL IMAGE AND SIGNAL PROCESSING: EVOLUTION IN REMOTE SENSING (WHISPERS), 2016,
  • [9] Snapshot Hyperspectral Imaging Fourier Transform Spectropolarimeter
    Youngs, E. J.
    Kudenov, M. W.
    POLARIZATION SCIENCE AND REMOTE SENSING VIII, 2017, 10407
  • [10] SNR of the coded aperture imaging system
    Wang, Jianwei
    Zhao, Yan
    OPTICAL REVIEW, 2021, 28 (01) : 106 - 112